GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of earth sciences 75 (1986), S. 293-300 
    ISSN: 1437-3262
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Description / Table of Contents: Abstract The temperature history of the Northwest German Basin has been reconstructed using a one-dimensional computer model that accounts for compaction-related changes of physical rock properties, depth, temperature and maturity of organic matter. Maturity has been modelled by empirically relating vitrinite reflectance to time-temperature history. Heat flow values for the Mesozoic and Carboniferous have been obtained by matching measured and computed vitrinite reflectance. For Mesozoic samples agreement between measured and computed maturity can be achieved with a heat flow between 37 and 50 mW/m2 (0.9 and 1.2 hfu). There is no systematic areal variation. Carboniferous samples are matched best at heat flows between 70 and 96 mW/m2 (1.7 and 2.3 hfu), corresponding to geothermal gradients between 50 and 80 °C/km depending on lithology and compaction. Areal variation follows patterns subparallel to the structural grain of the Variscan orogeny. Mesozoic heat flow is compatible with heat flow in stable platform areas. Carboniferous heat flow and its geotectonic setting are best in agreement with present-day back-arc areas underlain by continental crust.
    Abstract: Résumé L'histoire thermique du bassin allemand nord-occidental a été simulée sur ordinateur au moyen d'un modéle unidimensionnel; ce modèle tient compte des changements introduits par la compaction dans les propriétés physiques de roches, de la profondeur, de la température et de l'évolution de la matière organique. Pour modéliser cette évolution, on a établi une corrélation entre la réflectance de la vitrinite et l'histoire thermique. Les valeurs du flux de chaleur pour le Mésozoïque et le Carbonifère ont été obtenues par ajustement entre la réflectance de la vitrinite observée et calculée. Pour les échantillons mésozoïques, les valeurs calculées et mesurées s'accordent le mieux pour un flux compris entre 37 et 50 mW/m2 (0.9 et 1,2 HFU). Il n'y a pas de variation régionale systématique. Pour le Carbonifère, le meilleur accord donne un flux siuté entre 70 et 96 mW/m2 (1,7 et 2,3 HFU), ce qui correspond à des gradients géothermiques de 50 et 80 °C/Km, selon la lithologie et le degré de compaction. Il existe dans le Carbonifère, des variations régionales, qui parallélisent les lignes structurales de l'orogène varisque. Le flux de chaleur mésozoïque est compatible avec une situation de plate-forme stable. Le flux de chaleur carbonifère et sa répartition géotectonique fait plutôt penser, dans la nature actuelle, aux régions d'arrière-arc sur croûte continentale.
    Notes: Zusammenfassung Die Temperaturgeschichte des Nordwestdeutschen Bekkens wurde mittels eines eindimensionalen Computermodells rekonstruiert, das auch kompaktionsbezogenen Änderungen der physikalischen Gesteinseigenschaften, der Tiefe und der Temperatur gerecht wird. Die Reife wurde simuliert, indem Vitrinitreflexion und Zeit-Temperatur Verlauf empirisch miteinander korelliert wurden. Die Wärmeflußwerte für das Karbon und das Mesozoikum wurden dadurch ermittelt, daß gemessene und berechnete Vitrinitreflexion in optimale Übereinstimmung gebracht wurden. Für das Mesozoikum kann eine Übereinstimmung bei Wärmeflußwerten zwischen 37 und 50 mW/m2 (0.9 und 1,2 hfu), für das Karbon für Werte zwischen 70 und 96 mW/m2 (1.7 und 2.3 hfu) erzielt werden, was je nach Lithologie und Kompaktionszustand einem Geothermalgradienten zwischen 50 und 80 °C/km entspricht. Nur für die karbonischen Daten ist eine systematische räumliche Änderung der Werte erkennbar. Der Wärmefluß im Mesozoikum entspricht dem in heutigen stabilen Plattformgebieten. Wärmefluß und geotektonische Position im Karbon sind vergleichbar mit solchen heutigen »back-arc« Gebieten, die von kontinentaler Kruste unterlagert sind.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 210 (1950), S. 399-403 
    ISSN: 1432-1912
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung Nach einer kurzen Übersicht über die möglichen Tiernarkosen wird die bei uns geübte Technik der Narkose an Versuchstieren geschildert: ausreichende Schlaftiefe und genügend lange Operationsreife wurden mit intramuskulären Gaben von 0,1 g Evipan-Natrium pro Kilogramm Körpergewicht erreicht. Wichtig ist die Vorbereitung der größeren Versuchstiere mit je 1 Teilstrich „SEE schwach“ (Scopolamin, Ephedrin, Eukodal=„Scophedal“) pro Kilogramm Körpergewicht. Todesfälle wurden mit diesem Verfahren nicht mehr gesehen, Versager sind selten.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 269 (1951), S. 365-376 
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Clinical and experimental medicine 139 (1965), S. 589-603 
    ISSN: 1591-9528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary It could be demonstrated that intragastric pH values as determined by the use of the “Endoradio-Pill” (Heidelberger Kapsel) were different from readings obtained an fractionated gastric juice by means of the glass electrode. The differences were found to be inconsistent over the trial period and dependent upon changes in the constitution of the electrolytes. On the basis of these observations the electrode constants of the isolated combined pH electrods of Endoradio-Pills were measured in a buffered solution. Also, the influence of different electrolyte systems was determined and it was found that the electrode constantA varied with changes in the system. This variation gave rise to false values up to 2 pH units. The causes for this behavior are shown by a diagramm which summarizes the function of the Endoradio-Pill. The reference potential can be changed by coupling the combined pH electrode with a source of potential disturbance via the corresponding inner and outer resistances. The main source of disturbance in the examined Endoradio-Pill is due to the magnesium electrode, which in connection with the silver/silverchloride electrode — the latter being the reference electrode for the combined pH electrode — makes up the battery for the transistor transmittor.
    Notes: Zusammenfassung Mit der Endoradiosonde (Heidelberger Kapsel) intragastral gemessene pH-Werte zeigten Abweichungen gegenüber den pH-Werten, die in den entsprechenden ausgeheberten Magensaftportionen mit der Glaselektrode gemessen wurden. Die festgestellten Differenzen erwiesen sich über die Versuchszeit inkonstant und waren abhängig von Änderungen in der Zusammensetzung der Elektrolyte. Auf Grund dieser Beobachtung wurden die Elektrodenkonstanten isolierter pH-Meßketten von Endoradiosonden in Pufferlösung bestimmt. Sodann wurde der Einfluß verschiedener Elektrolytsysteme untersucht und festgestellt, daß sich die ElektrodenkonstanteA in Abhängigkeit vom Elektrolytsystem verändert. Diese Änderung der ElektrodenkonstanteA bewirkte Meßwertverfälschungen bis zu 2 pH-Einheiten. Die Gründe für dieses Verhalten werden an Hand eines, die Funktion der Endoradiosonde zusammenfassendes Schaltbildes, abgeleitet. Durch die gegebene Koppelung der pH-Meßkette mit Störspannungsquellen über die entsprechenden Innen- und Außenwiderstände kann sich das Bezugspotential verändern. Als wesentliche Störspannungsquelle in der untersuchten Endoradiosonde muß die Magnesiumelektrode angesehen werden, welche in Verbindung mit der Silber/Silberchloridelektrode, die gleichzeitig Bezugselektrode der pH-Meßkette ist, die Stromversorgungsbatterie des Transistorsenders bildet.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2012-11-07
    Description: Third-generation storage rings are modern facilities working with high currents and designed to host powerful radiation sources, like undulators and wigglers, and to deliver high-brilliance beams to users. Many experiments at high spatial resolution, such as spectromicroscopy at the nanometre scale and with high temporal resolution to investigate kinetics down to the picosecond regime, are now possible. The next frontier is certainly the combination of different methods in a unique set-up with the ultimate available spatial and temporal resolutions. In the last decade much synchrotron-based research has exploited the advantage of complementary information provided by time-resolved X-ray techniques and optical methods in the UV/Vis and IR domains. New time-resolved and concurrent approaches are necessary to characterize complex systems where physical–chemical phenomena occur under the same experimental conditions, for example to detect kinetic intermediates via complementary but independent observations. In this contribution we present scientific cases from original works and literature reviews to support the proposed IR/X-ray simultaneous approach, with both probes exploiting synchrotron radiation sources. In addition, simple experimental layouts that may take advantage of the high brilliance and the wide spectral distribution of the synchrotron radiation emission will be given for specific researches or applications to investigate dynamic processes and non-equilibrium phenomena occurring in many condensed matter and biological systems, of great interest for both fundamental research and technological applications.
    Print ISSN: 0909-0495
    Electronic ISSN: 1600-5775
    Topics: Geosciences , Physics
    Published by Wiley-Blackwell on behalf of International Union of Crystallography (IUCr).
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2023-05-12
    Keywords: Area/locality; Conductivity, average; Depth, bottom/max; Heat flow; LATITUDE; LONGITUDE; Number of temperature data; Sample, optional label/labor no; Temperature gradient
    Type: Dataset
    Format: text/tab-separated-values, 7 data points
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2023-05-12
    Keywords: Area/locality; Conductivity, average; ELEVATION; Heat flow; LATITUDE; LONGITUDE; Method comment; Number; Sample, optional label/labor no; Temperature gradient
    Type: Dataset
    Format: text/tab-separated-values, 540 data points
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...