GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 41 (1963), S. 577-580 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung Es wird ein neues Verfahren zur automatischen Untersuchung von Enzymkinetiken angegeben. Die Umsatzgeschwindigkeit einer Enzymreaktion in Abhängigkeit von jeweils einer veränderlichen Größe wird hierbei am durchlaufenden Reaktionsgemisch kontinuierlich gemessen und registriert. Unabhängige Veränderliche kann eine Konzentration (z. B. Substrat-, Coenzym-, Wasserstoffionenkonzentration) oder die Temperatur sein. Am Beispiel der Ermittlung einer Aktivitäts-pS-Kurve (Koordinaten:v=Umsatzgeschwindigkeit;pS=negativer Logarithmus der Substratkonzentration) wird das Verfahren im Einzelnen beschrieben. Unsere Methode eignet sich bisher zur Untersuchung von Enzymen, deren Umsatz durch Messung der Lichtabsorption erfaßbar ist. Als Beispiel werden Aktivitäts-pS-Kurven von Lactatdehydrogenase aus menschlichem Herzmuskel- und Leberhomogenisat sowie von Kaninchenmuskel-LDH gezeigt und die ermittelten Michaeliskonstanten angegeben.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 43 (1956), S. 398-399 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Clinical and experimental medicine 139 (1965), S. 589-603 
    ISSN: 1591-9528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary It could be demonstrated that intragastric pH values as determined by the use of the “Endoradio-Pill” (Heidelberger Kapsel) were different from readings obtained an fractionated gastric juice by means of the glass electrode. The differences were found to be inconsistent over the trial period and dependent upon changes in the constitution of the electrolytes. On the basis of these observations the electrode constants of the isolated combined pH electrods of Endoradio-Pills were measured in a buffered solution. Also, the influence of different electrolyte systems was determined and it was found that the electrode constantA varied with changes in the system. This variation gave rise to false values up to 2 pH units. The causes for this behavior are shown by a diagramm which summarizes the function of the Endoradio-Pill. The reference potential can be changed by coupling the combined pH electrode with a source of potential disturbance via the corresponding inner and outer resistances. The main source of disturbance in the examined Endoradio-Pill is due to the magnesium electrode, which in connection with the silver/silverchloride electrode — the latter being the reference electrode for the combined pH electrode — makes up the battery for the transistor transmittor.
    Notes: Zusammenfassung Mit der Endoradiosonde (Heidelberger Kapsel) intragastral gemessene pH-Werte zeigten Abweichungen gegenüber den pH-Werten, die in den entsprechenden ausgeheberten Magensaftportionen mit der Glaselektrode gemessen wurden. Die festgestellten Differenzen erwiesen sich über die Versuchszeit inkonstant und waren abhängig von Änderungen in der Zusammensetzung der Elektrolyte. Auf Grund dieser Beobachtung wurden die Elektrodenkonstanten isolierter pH-Meßketten von Endoradiosonden in Pufferlösung bestimmt. Sodann wurde der Einfluß verschiedener Elektrolytsysteme untersucht und festgestellt, daß sich die ElektrodenkonstanteA in Abhängigkeit vom Elektrolytsystem verändert. Diese Änderung der ElektrodenkonstanteA bewirkte Meßwertverfälschungen bis zu 2 pH-Einheiten. Die Gründe für dieses Verhalten werden an Hand eines, die Funktion der Endoradiosonde zusammenfassendes Schaltbildes, abgeleitet. Durch die gegebene Koppelung der pH-Meßkette mit Störspannungsquellen über die entsprechenden Innen- und Außenwiderstände kann sich das Bezugspotential verändern. Als wesentliche Störspannungsquelle in der untersuchten Endoradiosonde muß die Magnesiumelektrode angesehen werden, welche in Verbindung mit der Silber/Silberchloridelektrode, die gleichzeitig Bezugselektrode der pH-Meßkette ist, die Stromversorgungsbatterie des Transistorsenders bildet.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...