GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Publikationsart
Schlagwörter
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Publikationsdatum: 2024-03-22
    Beschreibung: We simulated an experimental summer storm in large-volume (~1200 m3, ~16m depth) enclosures in Lake Stechlin by mixing deeper water masses from the meta- and hypolimnion into the mixed layer (epilimnion). The mixing included the disturbance of a deep chlorophyll maximum (DCM) which was present at the same time of the experiment in Lake Stechlin and situated in the metalimnion of each enclosure during filling. Water physical variables and water chemistry was monitored for 42 days after the experimental disturbance event. Mixing disrupted the thermal stratification, increasing concentrations of dissolved nutrients and CO2 and changing light conditions in the epilimnion. Mixing, thus, stimulated phytoplankton growth, resulting in higher particulate matter concentrations of carbon, nitrogen and phosphorous.
    Schlagwort(e): Alkalinity, total; Ammonium; Ammonium molybdate reaction (FIASTAR 5000), (0.3 µm GF-75 prefiltered (Sterlitech)); BIBS; Bicarbonate ion; Bridging in Biodiversity Science; Calcium; Calcium carbonate; Calculated using seacarb after Nisumaa et al. (2010); Carbon, inorganic, particulate; Carbon, organic, dissolved; Carbon, organic, particulate; Carbon, total, particulate; Carbonate ion; Carbon dioxide; Carbon dioxide, partial pressure; Chloride; Climate change; Climate driven Changes in Biodiversity of Microbiota; Conductivity, electrolytic; cyanobacteria; DATE/TIME; Day of experiment; DCM; DEPTH, water; Depth of Secchi Disk; Description; Difference derived from TPC and PIC; disturbance; ELTRA-800 (0.3 µm GF-75 filters (Sterlitech)); enclosure; Enclosure experiment; Flow-injection analyzer; Flow-injection analyzer (0.3 µm GF-75 prefiltered (Sterlitech)); Fugacity of carbon dioxide in seawater; Germany; High temperature combustion, infra-red detection (Shimadzu), (0.3 µm GF-75 prefiltered (Sterlitech)); Infralyt 50 (SAXON Junkalor GmbH), (0.3 µm GF-75 filters (Sterlitech)); Ion chromatography (Dionex), (0.3 µm GF-75 prefiltered (Sterlitech)); lake; Lake_Stechlin; Magnesium; mesocosm; Mesocosm label; Nitrate; Nitrite; Nitrogen, total; Nitrogen, total, particulate; Nitrogen, total dissolved; NITROLIMIT; Oxygen; Oxygen/Nitrogen ratio; Oxygen saturation; Oxygen sensor, YSI6560; PAR sensor Li-193SA, LI-COR Inc.; Peroxodisulfate oxidation method; Flow-injection analyzer; 0.3 µm GF-75 filters (Sterlitech); pH; Phosphorus, reactive soluble; Phosphorus, total; Phosphorus, total, particulate; Potassium; Pressure, technical; Radiation, photosynthetically active; SD; Secchi disk; Silicate, dissolved; Sodium; Stickstofflimitation in Binnengewässern; Sulfate; summer storm; TemBi; Temperature, air; Temperature, water; Titration; Treatment; Vaisala Weather station WXT520; water chemistry; water physics
    Materialart: Dataset
    Format: text/tab-separated-values, 10528 data points
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...