GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of mathematical biology 48 (1986), S. 229-236 
    ISSN: 1522-9602
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Mathematics
    Notes: Abstract The theory of maximum principles is applied to a nonlinear differential equation representing a heat conduction model of the human head to obtain accurate analytical upper and lower bounding curves.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 313 (1983), S. 133-135 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Finite temperature HFB calculations have been performed in a model using the Surface Delta Interaction as the generating two body force. TheT=0 as well as theT=1 multipole pair fields are studied at various temperatures and different angular momenta. Higher multipole modes appear not only to be more resistant against increasing angular frequency but also against increasing temperature in comparison with the standard monopole pairing mode.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1430-4171
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The synthesis of tris(diethyldithiocarbamato) cobalt(III) by the reaction of sodium diethyldithio-carbamate and cobaltous chloride is described. The recovered crystals of the cobalt complex are characterized by magnetic susceptibility, IR and NMR spectroscopy, and cyclic voltammetry.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0533
    Keywords: Key words Meningoencephalitis ; Human herpesvirus 6 ; Lymphocyte ; Progressive multifocal leukoencephalopathy ; HIV
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Human herpesvirus 6 (HHV6) has been reported as a rare cause of meningoencephalitis and leukoencephalitis. We present an HIV-infected patient with ¶lesions of progressive multifocal leukoencephalopathy (PML), but also meningoencephalitis apparently due to HHV6. Immunohistochemistry for HHV6 antigens and in situ polymerase chain reaction for HHV6 genome showed many positive lymphocytes and microglia in the meningeal and cortical lesions. More importantly, dead and dying neurons were conspicuous; some were undergoing neuronophagia and some displayed evidence of HHV6 infection. A pathogenic role for this almost universal, and usually commensal, virus in inflammatory brain lesions and PML is briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric radiology 9 (1980), S. 244-246 
    ISSN: 1432-1998
    Keywords: Pneumothorax ; Bronchiolitis ; Atelectasis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Pneumothorax is an uncommon complication of bronchiolitis. This case illustrates an unusual pattern of atelectasis of the right lung with pleural air surrounding the right upper lobe and the remainder of the lung expanded. It is thought that the hyperinflated lung is unable to collapse as a result of the ‘ball valve’ effect of air trapping.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    International journal of colorectal disease 3 (1988), S. 201-203 
    ISSN: 1432-1262
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report two cases of FAP associated with gastric carcinoma. The literature on this subject, with special reference to ‘fundic gland polyposis’ is reviewed.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of industrial microbiology and biotechnology 17 (1996), S. 228-234 
    ISSN: 1476-5535
    Keywords: colonization ; biofilm ; diversity ; proximal vertical packing ; cell-cell interaction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract Using laminar flow chambers and time-lapse video imaging, colonization of surfaces by four marine bacteria revealed a diverse range of morphological characteristics and cell-cell interactions. The strain SW5 formed a compact, multilayered single- and double-cell biofilm on hydrophobic surfaces but developed long multicellular chains on hydrophilic surfaces. The morphologically similar SW8 showed unusual proximal vertical packing of cells on both substrata.Vibrio sp strain S14 exhibited cyclical colonization-detachment events on both substrata.Pseudomonas sp strain S9 initially displayed reversible and then irreversible adhesion apparently triggered by a cell density phenomenon that led to the development of regular microcolonies on both substrata with individual cells translocating between the colonies. The length of time bacteria were exposed to and their density at a surface influenced behavioral traits, with diverse and distinctive species-specific behavioral events.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 10 (1972), S. 483-495 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Un moyen a été développé pour évaluer la tension isométrique intégrée, rapport dp/dt pur obtenir des renseignements quantitatifs sur la contractilité myocardiale pour les préparations animales chroniques et aiguës durant l'administration de produits pharmaceutiques. Basé sur des techniques d'ordinateur analogue, l'instrument prélève la pression ventriculaire et le taux de changement de la pression ventriculaire (dp/dt) durant la phase de contraction isovolumique se produisant avant le sommet dp/dt. La tension isométrique obtenue est integrée et emmagasinée. La valeur maximum de dp/dt est aussi emmagasinée. Les deux valuers sont alors relevées simultanément, la division est exécutée par un diviseur analogue, et une pulsation de 100 ms dont la hauteur est proportionnelle au rapport (et ainsi la contractilité myocardiale) est envoyée dans un enregistreur. On se sert de l'onde R de l'e.c.g. pour mettre en marche le prélèvement des ondes de pression ventriculaire. Une pulsation derivée du maximum dp/dt met fin au prélèvement et amorce le rétablissement de l'instrument, prêt pour l'onde R suivante. De cette manière, on obtient une mesure, de la contractilité myocardiale d'un battement à l'autre.
    Abstract: Zusammenfassung Man hat für die Bestimmung der quantitativen Auskunft über Herzmuskel-Zusammenziehbarkeit in akuten und chronischen tierischen Präparationen, während der Verabreichung von Drogen, eine Einrichtung für die Ausrechnung der Größe dp/dt integrierter isometrischen Spannung entwickelt. Mit der Verwendung der Analog-Computer Techniken nimmt das Instrument Proben des ventrikulären Druckes und der Wechselgeschwindigkeit des ventrikulären Druckes (dp/dt), während der Phase der isovolumischen Zusammenziehung bevor der dp/dt Spitze. Die isometrische Spannung dabei erreicht, wird integriert und gespeichert. Der Spitzenwert der dp/dt wird auch gespeichert. Proben der beiden Werte werden danach simultan genommen, die Teilung wird von einem Analog-Teiler unternommen und ein Impuls von 100 ms, dessen Amplitude proportional zum Verhältnis ist (und daher Herzmuskel-Zusammenziehbarkeit) wird an einen Streifenblattschreiber gespeist. Die R-Welle des EKG wird verwendet, um die Probennahme der ventrikuläre Druckwelle zu beginnen. Ein von der dp/dt Spitze abgeleiteter Impuls beendet die Probennahme und schaltet das Instrument auf die nächste R-Welle über. Auf diesem Wege, wird eine Schlag-zu-Schlag Abmessung der Herzmuskel-Zusammenziehbarkeit erzielt.
    Notes: Abtract To obtain quantitative information about myocardial contractility in acute and chronic animal preparations during drug administration, a device for computing the ratio dp/dt: integrated isometric tension has been developed. Based on analogue computer techniques, the instrument samples ventricular pressure and the rate of change of ventricular pressure (dp/dt), during that phase of isovolumic contraction occurring before peak dp/dt. The isometric tension obtained is integrated and stored. The peak value of dp/dt is also stored. The two values are then simultaneously sampled, the division is performed by an analogue divider, and a 100 ms pulse whose height is proportional to the ratio (and thus myocardial contractility) is fed to a chart recorder. The R wave of the e.c.g. is used to start sampling of the ventricular pressure wave. A pulse derived from the peak dp/dt terminates sampling, and initiates resetting of the instrument ready for the next R wave. In this way, a beat-to-beat measure of myocardial contractility is obtained.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 6 (1968), S. 477-486 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire L’article présente une version simplifiée d’un filtre actif RC passe-bas. Ces filtres utilisent des amplificateurs différentiels opérationnels transistorisés et sont calculés pour présenter une haute impédance d’entrée et une faible impédance de sortie. Les filtres actifs RC peuvent permettre un fonctionnement stable et sans distorsion, et évitent les limitations inhérentes aux filtres passifs RC et LC. L’article présente deux filtres actifs passe-bas utilisables comme étages de sortie pour des débitmètres électromagnétiques: l’un avec un gain passe-bande de ×1, une réponse en fréquence uniforme jusqu’à environ 20 Hz, et un écart de phase linéaire de 3°/Hz; le second ayant un gain passe-bande de ×2, une réponse en fréquence uniforme jusqu’à environ 30 Hz, et un écart de phase linéaire de 2,20°/Hz. L’atténuation de ces filtres est 12 dB/octave. Un filtre actif RC passe-bas plus souple a été obtenu en utilisant deux étages semblables en cascade. Trois fréquences de coupure ont été choisies: 25 Hz, 50 Hz, et 100 Hz. Le gain passe-bande est ×1, tandis que l’atténuation de 12 dB/octave ou 24 dB/octave est sélectionnée en prenant la sortie de l’un ou l’autre des étages. Une calibration dynamique met en évidence la réponse en fréquence uniforme et l’écart de phase linéaire dans la bande passante; la réponse à l’échelon unité présente un overshoot de 3% pour la sortie à 12 dB, et de 11% pour la sortie à 24 dB.
    Abstract: Zusammenfassung Eine vereinfachte Methode zur Entwicklung RC-aktiver Tiefpaßfilter wird mitgeteilt. Die Filter verwenden Festkörper-Differentialverstärker bei hoher Eingangs- und niedriger Ausgangsimpedanz. RC-aktive Filter können stabile und verzerrungsfreie Leistung bei niedrigen Frequenzen ohne die Begrenzungen passiver RC- und LC-Filter abgeben. Zwei aktive Tiefpaßfilter, die für den Ausgang elektromagnetischer Flowmeter geeignet sind, werden beschrieben; der eine hat eine Paßbandverstärkung von 1, uniforme Frequenzansprechbarkeit bei etwa 20 Hz und lineare Phasenverschiebung von 3°/Hz; der zweite hat eine Paßbandverstärkung von 2, uniforme Frequenzansprechbarkeit bis etwa 30 Hz und lineare Phasenverschiebung von 2,2°/Hz. Die Dämpfungsrate der Filter ist 12 dB/Oktave. Ein vielseitiges aktives RC-Tiefpaßfilter wurde entwickelt. Es benutzt zwei derartige Stufen in Kaskadenschaltung. Die Wahl der drei Abschneidefrequenzen von 25, 50 und 100 Hz ist möglich. Die Paßbandverstärkung ist 1. Die Dàmpfungsrate ist 12 dB/Oktave oder 24 dB/Oktave, wenn der Ausgang von der ersten bzw. der zweiten Stufe abgenommen wird. Dynamische Eichung ergibt uniforme Frequenzansprechbarkeit und lineare Phasenverschiebung in dem Paßband, während eine Stufenfunktion einen 3% Overshoot von dem Kanal mit 12 bB/Oktave und 11% Overshoot von dem Kanal mit 24 dB/Oktave erzeugt.
    Notes: Abstract A simplified method of designing R-C active low-pass filters is presented. The filters employ solid-state differential operational amplifiers, and are designed to present high input impedance and low output impedance. R-C active filters can provide stable and distortion-free operation at low frequencies without the inherent limitations of passive R-C and L-C filters. Two active low-pass filters suitable for use in electromagnetic flowmeter output stages are illustrated; one with a pass-band gain of ×1, uniform frequency response to approximately 20 c/s and linear phase shift of 3°/cycle per second; and a second with a pass-band gain of ×2, uniform frequency response to approximately 30 c/s and linear phase shift of 2·2°/cycle per second. The attenuation rate of these filters is 12 dB/octave. A more versatile R-C active low-pass filter has been developed using two similar stages in cascade. The choice of three cut-off frequencies, 25 c/s, 50 c/s and 100 c/s is provided. Pass-band gain is ×1, while attenuation rates of 12 dB/octave or 24 dB/octave are selected by taking the output from either the first or second stage. Dynamic calibration shows uniform frequency response and linear phase shift in the pass-band, while the response to a step function shows 3 per cent overshoot from the 12 dB/octave channel, and 11 per cent overshoot from the 24 dB/octave channel.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 7 (1969), S. 115-132 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire On a mis au point un débitmètre électromagnétique transistorisé à signaux carrés à 400 c/s, dont le rapport signal-sur-bruit est parfaitement compatible avec l'utilisation des capteurs sans noyau, ou à noyau de fer à faible sensibilité, qui sont habituellement utilisés avec les débitmètres à signaux sinusoïdaux. Le débitmètre présente une réponse en fréquence essentiellement uniforme et un écart de phase linéaire jusqu'à 30 c/s. La bande passante va du continu jusq'à 45 c/s environ. Le bruit ramené à l'entrée est de 0,14 μV efficace quand l'impédance de la source est inferieure à 10 kΩ. L'impédance d'entrée differentielle est de 60 MΩ, alors que l'impédance d'entrée en mode commun est de 150 MΩ; le taux de réjection du mode commun est de 106 dB, de 40 à 400 c/s. L'amplificateur est conditionné par un circuit à porte de manière à supprimer crête l'harmonique 2 du signal. On peut tolérer un résidu de l'harmonique 2 jusqu'à 12 mV crète dans les électrodes avant que la saturation de l'amplificateur n'entraine une dérive de la ligne de base. Le courant magnétique capté est fixé à 1 A crête, et est maintenu constant par un amplificateur de courant à contre-réaction. Avec l'aide de capteurs de débit convenable, on obtient une bonne stabilité de la ligne de base, et on peut régler le zéro électriquement, sans avoir à interrompre le débit.
    Abstract: Zusammenfassung Ein elektromagnetisches Rechteckwell-Flowmeter mit 400 c/s wurde entwickelt. Bei niedrigem Signal-Rausch-Verhältnis werden kernlose und wenig empfindliche Eisenkern-Transducer benutzt, ähnlich den in den üblichen Sinuswellen-Flowmetern verwendeten. Das Flowmeter hat einen im wesentlichen uniformen Frequenzgang und eine lineare Phasenverschiebung von 30 c/s. Die Ausgangsbandbreite ist im Gleichstrom 45 c/s. Das entsprechende Rauschen am Eingang ist 0, 14 μV r.m.s., wenn die Quellenimpedanz weniger als 10 KΩ beträgt. Die Differentialimpedanz am Eingang ist 60 MΩ, während die einfache Eingangsimpedanz bei 150 MΩ liegt; die Unterdrückung ist 106 dB von 40 bis 400 c/s. Zur Unterdrückung des Quadratursignals wird eine Verstärker-Torschaltung verwendet. An den Aufnahmeelektroden kann ein Gipfel des Quadratursignalsbis zu 12 mV toleriert werden, bevor Verstärkersättigung und damit Grundlinienverschiebung auftritt. Der Strom am Transducermagneten ist auf 1 A. (Gipfel) festgelegt und wird durch einen rückgekoppelten Stromverstärker konstant gehalten. Mit geeigneten Flußtransducern ist die Grundlinienstabilität groß und kann ohne Flußunterbrechung elektrisch erhalten werden.
    Notes: Abstract A 400 c/s transistorized squarewave electromagnetic flowmeter has been developed with adequate signal-to-noise ratio for use with coreless and low sensitivity iron-cored transducers such as those commonly used with sinewave flowmeters. The flowmeter has substantially uniform frequency response and linear phase shift to 30 c/s. Output bandwidth is d.c. to approximately 45 c/s. The equivalent noise at the input is 0·14 μV r.m.s. when the source impedance is less than 10 kΩ. Differential input impedance is 60 MΩ, while common mode input impedance is 150 MΩ; common mode rejection is 106 dB from 40 c/s to 400 c/s. Amplifier gating is used to suppress quadrature signal; up to 12 mV peak of quadrature signal can be tolerated at the pick-up electrodes before amplifier saturation causing baseline shift occurs. Transducer magnet current is preset at 1 A peak, and is held constant by a feedback-controlled current amplifier. With suitable flow transducers, baseline stability is high, and zero can be obtained electrically without interrupting flow.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...