GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical and experimental dermatology 6 (1981), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In an attempt to define better the histopathological changes occurring in the skin in patients with perniosis, biopsies from twenty-six patients were examined independently by the two authors. In the majority of cases one of two characteristic histopathological patterns was seen. The histological differential diagnosis of perniosis is reviewed.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 24 (1991), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: From a total of 993 previously reported cases of occupational skin disease (OSD), 954 (96%) were contacted and 711 (75%) examined, The review time (i.e., period from original diagnosis of OSD until review] varied from u minimum of 6 months to a maximum of over 8 years. Over 60% of cases were reviewed more than 2 years after the original diagnosis was made. More than 50% were still suffering from OSD or consequences related thereto. Clearance was less likely in those who remained in their original, or similar, occupational environment. However, of those who changed their job due to OSD. Many suffered aggravation of the dermatitis from factors in the new work environment. Over 10% of cases had evolved into a persistent post occupational dermatitis without obvious cause. This condition is responsible for considerable impairment and is of medicolegal importance due lo confusion as to its relationship to the original occupational factors.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 24 (1991), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: 993 cases of occupational skin disease (OSD) were diagnosed in a private dermatology practice over an 8–year period. Dermatologists wore the major source of referral. The sex ratio was 2.4 males to 1 female. Patch tests were conducted in 79% of cases. Wet work industries predominated in females; in males the causative industries were more varied. Apprentices were affected in a high proportion pf hairdressers and food handlers. Atopics accounted for 75% of the apprentice hairdressers. Atopics also were more prevalent in females with OSD than males. 29% of all eases had suffered from OSD for over 2 years before diagnosis. 75% of patients with OSD were less than 40 years of age at onset of OSD. Irritant contact dermatitis predominated over allergic contact dermatitis in all up; groups except those over 60 years of ape. Nickel was the predominant occupational allergen in females, whereas chromate was the predominant occupational allergen in males. 46% had been in the causative occupation for over 2 years before developing irritant contact dermatitis. Some new occupational allergens have emerged in recent years. OSD in Western Australia does not appear to differ in any major way from that reported from other countries.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 16 (1987), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Serum from guinea pigs exposed to a single high dose of UVB and from controls was injected into the spleen of normal animals 5 days prior to sensitization. When 1.0 ml was transferred 4.5 h after irradiation, immunosuppression was obtained. Transfer of 1.5 ml of serum 2.5 h after irradiation failed to induce immunosuppression. This experimental model in guinea pigs might be valuable in further studies investigating the effect of other modalities of ultraviolet exposure (e.g., PUVA or high-dose UVA) on the release of soluble serum factor(s) inducing immunosuppression in allergic contact dermatitis.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 16 (1987), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Open, closed and intradermal testing with NiCl2 was performed in 15 subjects with patch-test-proven allergy to 5% NiSO4 in pet. Intradermal testing proved to be a reliable method in confirming nickel sensitivity within 24 h. Open testing with non-toxic concentrations of NiCl2 in alcohol resulted in 73% and 93% positive reactions at 24 h and 48 h readings, respectively. This test method can be used as a reliable screening method in nickel allergy. Open testing often resulted in positive reactions within a few hours. This makes it possible to investigate pathogenetic events of acquired allergic contact dermatitis at a much earlier stage than with the usual 48-h occlusion. 24-h occlusion with Finn Chambers is not sufficient if one is to avoid false negative reactions in nickel allergy. Occlusion with Finn Chambers seems to delay the reaction.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 6 (1980), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Positive patch tests confirm nickel penetration through rubber gloves. Dimethylglyoxime (DMG) results indicate that nickel reactivity may occur where DMG testing is negative.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 23 (1990), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Contact dermatitis 15 (1986), S. 0 
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Sodium cromoglycate was applied to the Forearm of 9 subjects with known delayed hypersensitivity, and to the back of 14 dinitrochlorobenzene-sensitized guinea pigs before challenge with the allergen and sodium lauryl sulphate, Sodium cromoglycate did not decrease the intensity of allergic or toxic-irritant reactions in either humans or guinea pigs.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Australasian journal of dermatology 26 (1985), S. 0 
    ISSN: 1440-0960
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Australasian journal of dermatology 25 (1984), S. 0 
    ISSN: 1440-0960
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A case is reported of allergic contact sensitivity to dimer acid product—a hot-cure flexibilizing epoxy resin hardener Dimer acid product would appear to be allergenic potential despite its widespread usage.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...