GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-0581
    Keywords: Faults ; Mid-Atlantic Ridge ; sea beam ; wavelets ; filters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Digital filters designed using wavelet theory are applied to high resolution deep-towed side-scan sonar data from the median valley walls, crestal mountains, and flanks of the Mid-Atlantic Ridge at 29°10′ N. With proper tuning, the digital filters are able to identify the location, orientation, length, and width of highly reflective linear features in sonar images. These features are presumed to represent the acoustic backscatter from axis-facing normal faults. The fault locations obtained from the digital filters are well correlated with visual geologic interpretation of the images. The side-scan sonar images are also compared with swath bathymetry from the same area. The digitally filtered bathymetry images contain nine of the eleven faults identified by eye in the detailed geologic interpretation of the side-scan data. Faults with widths (measured perpendicular to their strike) of less than about 150 m are missed in the bathymetry analysis due to the coarser resolution of these data. This digital image processing technique demonstrates the potential of wavelet-based analysis to reduce subjectivity and labor involved in mapping and analyzing topographic features in side-scan sonar and bathymetric image data.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    Massachusetts Institute of Technology and Woods Hole Oceanographic Institution
    Publication Date: 2022-05-25
    Description: Submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy at the Massachusetts Institute of Technology and the Woods Hole Oceanographic Institution April 8, 1988
    Description: Several experiments are presented in this thesis which examine methods to measure and monitor fluid flow from hydrothermal vent fields. Simultaneous velocity, temperature, and conductivity data were collected in the convective flow emanating from a hydrothermal vent field located at 10°S6'N, 103° 41'W on the East Pacific rise. The horizontal profiles obtained indicate that the flow field approaches an ideal plume in the temperature and velocity distribution. Such parameters as total heat flow and maximum plume height can be estimated using either the velocity or the temperature information. The results of these independent calculations are in close agreement, yielding a total heat flow from this vent site of 3.7 ± 0.8 MW and a maximum height of 150±10 m. The nonlinear effects of large temperature variations on heat capacity and volume changes slightly alter the calculations applied to obtain these values. In Guaymas Basin, a twelve day time series of temperature data was collected from a point three centimeters above a diffuse hydrothermal flow area. Using concurrent tidal gauge data from the town of Guaymas it is shown that the effects of tidar currents can be strong enough to dominate the time variability of a temperature signal at a fixed point in hydrothermal flow and are a plausible explanation for the variations seen in the Guaymas Basin temperature data. Theoretical examination of hot, turbulent, buoyant jets exiting from hydrothermal chimneys revealed acoustic source mechanisms capable of producing sound at levels higher than ambient ocean noise. Pressure levels and frequency generated by hydrothermal jets are dependent on chimney dimensions, fluid velocity and temperature and therefore can be used to monitor changes in these parameters over time. A laboratory study of low Mach number jet noise and amplification by flow inhomogeneities confirmed theoretical predictions for homogeneous jet noise power and frequency. The increase in power due to convected flow inhomogeneities, however, was lower in the near field than expected. Indirect evidence of hydrothermal sound fields (Reidesel et al., 1982; Bibee and Jacobson, 1986) showing anomalous high power and low frequency noise associated with vents is due to processes other than jet noise. On Axial Seamount, Juan de Fuca Ridge, high quality acoustic noise measurements were obtained by two hydrophones located 3 m and 40 m from an active hydrothermal vent, in an effort to determine the feasibility of monitoring hydrothermal vent activity through floW noise generation. Most of the noise field could be attributed to ambient ocean noise sources of microseisms, distant shipping and weather, punctuated by local ships and biological sources. Water/rock interface waves of local origin, were detected which showed high pressure amplitudes near the seafloor and, decaying with vertical distance, produced low pressures at 40 m above the bottom. Detection of vent signals was hampered by unexpected spatial non- stationarity due to shadowing effects of the caldera wall. No continuous vent signals were deemed significant based on a criterion of 90% probability of detection and 5% probability of false alarm. However, a small signal near 40 Hz, with a power level of 1x10-4 Pa2/Hz was noticed on two records taken near the Inferno black smoker. The frequency of this signal is consistent with predictions and the power level suggests the occurrence of jet noise amplification due to convected density inhomogeneities. Ambient noise from the TAG (Trans-Atlantic Geotraverse) hydrothermal area on the Mid-Atlantic Ridge near 26°N, in the frequency band 1-30 Hz at a range of 0.75-14 km from the site of an extremely active high temperature hydrothermal vent field (Rona, 1986) was examined. The ambient noise field exhibits great temporal and spatial variations attributed in part to typical ocean noise sources such as distant shipping and microseisms. Power spectral levels as measured at each of six ocean bottom hydrophones (OBH) were used to estimate the location of point sources of sound in the area, if any. The hydrothermal vent did not produce enough sound to be located as a point source using data from the OBH array. The only consistently identifiable point source found with the data set was generating sound in a 0.8-3.5 Hz bandwidth and located outside the median valley. It appears to be harmonic tremor associated with the tip of a ridge on the western side of the spreading axis and may be volcanic in origin.
    Description: This work was supported by the WHOI/MIT Education Office, the Center for Analysis of Marine Systems, the National Science Foundation (grant OCE83-l0l75), NOAA National Sea Grant College Program Office, Dept. of Commerce under grant #NA86-AA-D-SG090, WHOI Sea Grant (R/6-l4), the Office of Naval Research grant #N0014-87-K-0007, and the NOAA Vents Program.
    Keywords: Hydrothermal vents ; Plumes ; Underwater acoustics
    Repository Name: Woods Hole Open Access Server
    Type: Thesis
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...