    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 25 (2002), S. 0 
    ISSN: 1540-8159
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: VOLLMANN, D., et al.: 1-Year Performance of a Defibrillation Lead with a Small Electrode Surface for High Impedance Pacing: A Randomized, Controlled Study. A small electrode surface reduces pacing current drain and can extend generator longevity. The study evaluated the performance of a tined, quadripolar defibrillation lead (model 6944) that has a small-surfaced, steroid-eluting electrode tip for high impedance pacing. In a prospective, controlled study, 34 patients with conventional ICD indications were randomized one to one to receive the high impedance model 6944 or a tined defibrillation lead with a conventional sized, steroid-eluting electrode tip model 6942. Lead performance was evaluated at implant, prior to hospital discharge, and 1, 3, 6, and 12 months thereafter. Baseline characteristics did not differ significantly between patients implanted with lead model 6942 (n = 16) or model 6944 (n = 17). One patient randomized to receive the model 6942 was excluded from the study and was implanted with an active-fixation lead after stable lead positioning was neither possible with the 6942 nor with the 6944 electrode. No other lead related adverse events were observed. At implant, there were no significant differences between pacing thresholds, sensing performance, defibrillation impedances, and defibrillation thresholds in both groups, but pacing impedance of the model 6944 (988.6 ± 217.7 Ω) was approximately twice as high as in the model 6942 (431.7 ± 83.7 Ω; P 〈 0.0001). This difference remained highly significant throughout the observation period of 12 months, while R wave amplitudes and pacing thresholds remained equal in both lead models. The use of a tined defibrillation lead with a small, steroid-eluting electrode tip appears safe and results in a high pacing impedance without compromising system performance.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1540-8159
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Algorithms that attempt to reconfirm the presence of an arrhythmia prior to definite treatment have been implemented in ICDs to prevent inappropriate shock therapy due to self-terminating ventricular arrhythmias. Nevertheless, in two patients, clinically inappropriate shocks were delivered after spontaneous conversion of the arrhythmia despite the use of a specific reconfirmation algorithm. Reconfirmation criteria were met due to a premature ventricular complex causing a short cycle in the first patient and a long postextrasystolic pause in the second patient. To avoid inappropriate shock therapy due to self-terminating ventricular arrhythmias, further improvement of detection algorithms is required. (PACE 1997; 20[Pt. I]:1328-1331)
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Journal of interventional cardiac electrophysiology 4 (2000), S. 269-272 
    ISSN: 1572-8595
    Schlagwort(e): ICD lead fracture ; painless lead impedance ; early detection
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We report the case of a 69 year old patient, who underwent transvenous implantable cardioverter defibrillator (ICD) device change (Medtronic GEM VR 7227 Cx Active Can) because the ICD reached its replacement indicators. Preoperative chest X-ray and intraoperative defibrillation threshold tests and high voltage impedance did not show lead fracture of the five year old lead (Transvene 6936-65). At the second postoperative day the alarm of the newly implanted ICD device was activated because of high impedance in the painless lead impedance measurement (PLI) and the lead was replaced. The explanted lead showed a fracture detectable only by PLI.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...