    Publikationsdatum: 2015-06-18
    Beschreibung: The objective of this work was to examine the feasibility of three-dimensional (3D) and whole heart coverage 23 Na cardiac MRI at 7.0 T including single-cardiac-phase and cinematic (cine) regimes. A four-channel transceiver RF coil array tailored for 23 Na MRI of the heart at 7.0 T ( f  = 78.5 MHz) is proposed. An integrated bow-tie antenna building block is used for 1 H MR to support shimming, localization and planning in a clinical workflow. Signal absorption rate simulations and assessment of RF power deposition were performed to meet the RF safety requirements. 23 Na cardiac MR was conducted in an in vivo feasibility study. 3D gradient echo (GRE) imaging in conjunction with Cartesian phase encoding (total acquisition time T AQ  = 6 min 16 s) and whole heart coverage imaging employing a density-adapted 3D radial acquisition technique ( T AQ  = 18 min 20 s) were used. For 3D GRE-based 23 Na MRI, acquisition of standard views of the heart using a nominal in-plane resolution of (5.0 × 5.0) mm 2 and a slice thickness of 15 mm were feasible. For whole heart coverage 3D density-adapted radial 23 Na acquisitions a nominal isotropic spatial resolution of 6 mm was accomplished. This improvement versus 3D conventional GRE acquisitions reduced partial volume effects along the slice direction and enabled retrospective image reconstruction of standard or arbitrary views of the heart. Sodium cine imaging capabilities were achieved with the proposed RF coil configuration in conjunction with 3D radial acquisitions and cardiac gating. Cardiac-gated reconstruction provided an enhancement in blood–myocardium contrast of 20% versus the same data reconstructed without cardiac gating. The proposed transceiver array enables 23 Na MR of the human heart at 7.0 T within clinical acceptable scan times. This capability is in positive alignment with the needs of explorations that are designed to examine the potential of 23 Na MRI for the assessment of cardiovascular and metabolic diseases. Copyright © 2015 John Wiley & Sons, Ltd. This pilot study demonstrated the feasibility of sodium MRI of the human heart at 7.0 T using a dedicated transceiver RF coil array. The proposed setup afforded the acquisition of sodium images with reasonable myocardial signal in clinically acceptable scan times. 3D density adapted radial acquisitions yielded a signal gain compared with Cartesian gradient echo acquisitions. This improvement supported whole heart, cine sodium imaging of the heart with an isotropic spatial resolution of 6 mm within approximately 19 min scan time.
    Print ISSN: 0952-3480
    Digitale ISSN: 1099-1492
    Thema: Medizin
    Publiziert von Wiley-Blackwell
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...