GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2024-04-20
    Description: Selected multicorer cores of R/V Sonne cruise SO268-2 were scanned by a Toshiba Aquilion 64 computer tomograph (CT) at the hospital Klinikum Bremen-Mitte with an x-ray source voltage of 120 kV and a current of 600 mA. The CT image stacks have a resolution of 0.35 mm in x/y-direction and 0.5 mm resolution in z-direction (0.3 mm reconstruction unit). Images were reconstructed using Toshiba's patented helical cone beam reconstruction technique (TCOT) and are provided in DICOM-format. The data were processed with the ZIB edition of the Amira software (version 2021.03; Stalling et al., 2005; http://amira.zib.de). Within Amira, the core liners, including about 2 mm of the core rims, were deleted from the data set. Mangan nodules with diameters 〉~1 mm, open bioturbation traces, an unidentified organism (only present in core SO268-2-200-1 MC18), the natural bioturbated and surficial homogenised sediment were segmented by a marker-based watershed segmentation and visualized in 3D. Subsequently, the sediment components were quantified (MaterialStatistics module; volume per slice) and the mean and standard deviation of the sediment x-ray attenuation (MaterialStatistics module; statistics per slice per label; to avoid marginal averaging effects the sediment label was reduced by three voxels) were determined.
    Keywords: Binary Object; Binary Object (File Size); bioturbation; Bioturbation; Clarion-Clipperton Fraction Zone, North East Pacific Ocean; Computer tomograph value; CT; DEPTH, sediment/rock; File content; JPI Oceans - Ecological Aspects of Deep-Sea Mining; JPIO-MiningImpact; manganese nodules; MUC-24; Multicorer with television; Nodules; Number of slice; Number of voxels, matrix sediment; SO268/2; SO268/2_122-1; Sonne_2; TVMUC; x-ray attenuation; X-ray attenuation, matrix sediment, maximum; X-ray attenuation, matrix sediment, mean; X-ray attenuation, matrix sediment, minimum; X-ray attenuation, matrix sediment, standard deviation
    Type: Dataset
    Format: text/tab-separated-values, 9480 data points
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...