  • 1
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: UNTERBERG, C., et al.: Long-Term Clinical Experience with the EGM Width Detection Criterion for Differentiation of Supraventricular and Ventricular Tachycardia in Patients with Implantable Cardioverter Defibrillators. Inappropriate therapy by ICDs due to SVTs is an important problem. A third generation ICD with a new detection criterion (“EGM width criterion”) for differentiation of SVTs and VTs by measuring the width of the intracardiac EGM was studied in 47 patients. A wide EGM was defined as the longest measured EGM plus 4–12 ms (programmed as EGM width threshold). EGM width detection function was programmed to the “Passive” mode so that no therapy was withheld. During a follow-up of 29.9 ± 8.3 (12–45) months, 489 spontaneous episodes were analyzed. SVTs occurred in ten patients with 305 episodes; 301 were correctly classified by use of the new detection criterion. In four patients four episodes were incorrectly detected as wide QRS tachycardias. Thus specificity for SVT was 98.7% (on a per episode basis) and 60% on a per patient basis. Of 184 VTs in 23 patients, 118 episodes were correctly classified (19 patients), however, in 4 patients 66 VTs were falsely detected as SVTs, 62 (94%) of which occurred in 1 patient with complete left BBB and continuously increasing QRS width in 12-lead surface ECGs. Overall sensitivity (on a per episode basis) for VT detection was 64.1% and 96.7% in patients with stable width of the QRS complex in a 12-lead surface ECG. These data show that this criterion is not superior to data on rate dependent detection criteria and furthermore not applicable in patients with complete BBB.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: VOLLMANN, D., et al.: 1-Year Performance of a Defibrillation Lead with a Small Electrode Surface for High Impedance Pacing: A Randomized, Controlled Study. A small electrode surface reduces pacing current drain and can extend generator longevity. The study evaluated the performance of a tined, quadripolar defibrillation lead (model 6944) that has a small-surfaced, steroid-eluting electrode tip for high impedance pacing. In a prospective, controlled study, 34 patients with conventional ICD indications were randomized one to one to receive the high impedance model 6944 or a tined defibrillation lead with a conventional sized, steroid-eluting electrode tip model 6942. Lead performance was evaluated at implant, prior to hospital discharge, and 1, 3, 6, and 12 months thereafter. Baseline characteristics did not differ significantly between patients implanted with lead model 6942 (n = 16) or model 6944 (n = 17). One patient randomized to receive the model 6942 was excluded from the study and was implanted with an active-fixation lead after stable lead positioning was neither possible with the 6942 nor with the 6944 electrode. No other lead related adverse events were observed. At implant, there were no significant differences between pacing thresholds, sensing performance, defibrillation impedances, and defibrillation thresholds in both groups, but pacing impedance of the model 6944 (988.6 ± 217.7 Ω) was approximately twice as high as in the model 6942 (431.7 ± 83.7 Ω; P 〈 0.0001). This difference remained highly significant throughout the observation period of 12 months, while R wave amplitudes and pacing thresholds remained equal in both lead models. The use of a tined defibrillation lead with a small, steroid-eluting electrode tip appears safe and results in a high pacing impedance without compromising system performance.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1572-8595
    Keywords: ICD lead fracture ; painless lead impedance ; early detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report the case of a 69 year old patient, who underwent transvenous implantable cardioverter defibrillator (ICD) device change (Medtronic GEM VR 7227 Cx Active Can) because the ICD reached its replacement indicators. Preoperative chest X-ray and intraoperative defibrillation threshold tests and high voltage impedance did not show lead fracture of the five year old lead (Transvene 6936-65). At the second postoperative day the alarm of the newly implanted ICD device was activated because of high impedance in the painless lead impedance measurement (PLI) and the lead was replaced. The explanted lead showed a fracture detectable only by PLI.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2012-05-02
    Description: Journal of the American Chemical Society DOI: 10.1021/ja2115184
    Print ISSN: 0002-7863
    Electronic ISSN: 1520-5126
    Topics: Chemistry and Pharmacology
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...