    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 159-163 
    ISSN: 0935-6304
    Keywords: Multi-dimensional chromatography ; LC-GC ; AED ; memory effects ; fossil fuel ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Conventional operation of the GC Atomic Emission Detector (AED) system involves backflushing of the microwave induced plasma (MIP) during the elution of small volumes of solvent from the GC column. When performing multi-dimensional, on-line LC-GC-AED, significantly larger solvent volumes are introduced into the system and must subsequently be removed. Thus solvent venting procedures are required and the backflushing of the plasma must be extended to facilitate solvent but not solute removal. This study demonstrates the significance of memory effects imparted upon the MIP of the AED if solvent venting is incomplete. Comparison of conventional GC-AED and multi-dimensional LC-GC-AED is made with respect to a fossil fuel sample.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Polycyclic aromatic compounds ; Coupled Liquid chromatography-gas chromatography-mass spectrometry ; Coupled liquid chromatography-gas chromatography-atomic emission detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The composition and concentration of polycyclic aromatic compounds (PAC) in fuels. Theier combustion products and in the atmosphere remains a topic of considerable interest. Despite the wealth of literature on the identification of PAC, speciation at low concentrations remains difficult due to instrument limitation and the complexity of fuel and environmental samples. Consequently on line sample preparation procedures (SPE, SFE, LC, etc.) are becomeing an increasingly important step in the analysis procedure particularly where sample clean-up and fractionation are essential for improving analytical resolution. In this study a normal phase high pressure analytical resolution. In this study a normal phase high pressure liquid chromatography-gas chromatography (LC-GC) system has been developed to provide quantitative analysis of samples, as diverse as coal liquids, petroleum fuels, diesel exhaust particulates, and urban air particulates. Separation and identification of parent and alkylated PAH, hetercycline nitro-and oxy-PAC can be achieved by direct coupling to an atomic emission detector and a bech top mass spectrometer. For both systems the primary LC separation combined with the large sample volume transferred to GC vastly improves detection limits. Furthermore the complimentary nature of the two detectors used enables the positive indentification of many unknowns.
    Additional Material: 6 Ill.