GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Arrhythmogenic right ventricular dysplasia is a structural heart disease characterized by fibrofatty degeneration of right ventricular myocardium and arrhythmias of right ventricular origin. The aim of this study was to characterize endocardial right ventricular activation by electroanatomic mapping as a guide for catheter ablation in patients with arrhythmogenic right ventricular dysplasia. Electroanatomic mapping and entrainment procedures were performed in 5 patients with arrhythmogenic right ventricular dysplasia. Endocardial mapping during ventricular tachycardia demonstrated a focal activation pattern with radial spreading of activation from a site of earliest ventricular activation in all directions. Right ventricular activation time (127 ± 34 ms) was markedly shorter than tachycardia cycle length (415 ± 92 ms). The site of earliest ventricular activation was found in an aneurysmal outflow tract (n = 2), at the border of aneurysms near the tricuspid annulus (n = 2), and at the apex of the right ventricle (n = 1). Entrainment mapping criteria of these areas of earliest endocardial activity were consistent with exit sites of a reentrant circuit in an area of abnormal myocardium. Fractionated potentials were found 61 ± 29 ms before the onset of the QRS complex at these sites. Catheter ablation rendered the “clinical“ ventricular tachycardia noninducible in four patients but “nonclinical” faster ventricular tachycardias were inducible in three patients. During the follow-up of 7 ± 3 months after ablation, the frequency of therapies in 4 patients with an implantable cardioverter defibrillator decreased from 49 ± 61 episodes per month before ablation, to 0.3 ± 0.5 episodes per month after ablation (P 〈 0.05). Electroanatomic mapping during ventricular tachycardia facilitates localization of exit sites in relation to aneurysms in diseased right ventricle and may guide catheter ablation in patients with arrhythmogenic right ventricular dysplasia. (PACE 2003; 26:1308–1316)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The success and safety of standard catheter radiofrequency ablation may be limited for ablation of atrial fibrillation and ventricular tachycardia. The aim of this study was to characterize and compare different cooled and noncooled catheter systems in terms of their specific lesion geometry, incidence of impedance rise, and crater and coagulum formation to facilitate appropriate catheter selection for special indications. The study investigated myocardial lesion generation of three cooled catheter systems (7 Fr, 4-mm tip): two saline irrigation catheters with a showerhead-type electrode tip (sprinkler) and a porous metal tip and an internally cooled catheter. Noncooled catheters (7 Fr) had a large tip electrode (8 mm) and a standard tip electrode (4 mm). RF energy was delivered on isolated porcine myocardium superfused with heparinized pig blood (37°C) at power settings of 10–40 W. Both irrigated systems were characterized by a large lesion depth ( 8.1 ± 1.6 mm ) and a large lesion diameter ( 13.8 ± 1.6 mm ). In comparison, internally cooled lesions showed a similar lesion depth ( 8.0 ± 1.0 mm ), but a significantly smaller lesion diameter ( 12.3 ± 1.2 mm , P = 0.04 ). Large tip lesions had a similar lesion diameter ( 14.5 ± 1.6 mm ), but a significantly smaller lesion depth ( 6.3 ± 1.0 mm , P = 0.002 ) compared to irrigated lesions. However, lesion volume was not significantly different between the three cooled and the large tip catheter. To induce maximum lesion size, power requirements were three times higher for the irrigation systems and two times higher for the internally cooled and the large tip catheter compared to the standard catheter. Impedance rise was rarest with irrigated and large tip ablation. In case of impedance rise crater formation was a frequent observation (61–93%). Irrigated catheters prevented coagulum formation most effectively. Irrigated rather than internally cooled ablation appears to be most adequate for the induction of deep and long lesions at a low rate of impedance rise and thrombus formation. Large tip ablation may be feasible for the creation of long linear lesions, however, with an increased risk of thrombus formation. (PACE 2003; 26[Pt. I]:1438–1445)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 14 (2003), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Implantable Defibrillator Lead Failure. Introduction: Patients with implantable cardioverter defibrillators (ICD) critically depend on correct functioning of their system. The aim of this study was to determine the incidence and clinical presentation of transvenous ICD lead failures during long-term follow-up. Methods and Results: The study group consisted of 261 consecutive patients who received Medtronic right ventricular polyurethane transvenous leads (models 6884, 6966, 6936) between 1990 and 1998 as part of an abdominal (n = 70) or pectoral (n = 191) ICD system. During mean follow-up of 4.0 ± 2.6 years , 31 patients (12%) developed a lead-related sensing failure with oversensing of artifacts. All failures except two were compatible with an insulation defect and occurred late after ICD placement ( 6.0 ± 1.8 years after implant). Lead survival decreased from 98% at 4-year follow-up to only 62% at 8-year follow-up. Lead survival was not related to patient age, sex, venous lead implantation route, or device implantation site. In 26 (87%) of 31 patients, a sensing defect resulted in inappropriate detection of ventricular fibrillation and subsequent delivery of 3 ± 3 (range 1–11) inappropriate shocks in 19 (61%) of 31 patients. Device interrogation showed artifacts classified as nonsustained ventricular tachycardia in 21 patients, 40 ± 43 days before clinically relevant failure of the system. One patient with a subclavian crush syndrome required resuscitation because of undersensing of true ventricular fibrillation. Conclusion: Transvenous polyurethane ICD leads showed a high rate of lead insulation failure late after implantation with frequent inappropriate shock deliveries. Close follow-up is mandatory in patients with these leads. Automated device control features with patient alert function integrated into new devices may contribute to early detection of lead failure.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1546-170X
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Medicine
    Notes: [Auszug] Selective skewing of autoreactive interferon-γ (IFN-γ)-producing T helper cells (Th1) toward an interleukin-4 (IL-4)-producing (Th2) phenotype can in experimental animals alleviate autoimmune disease without inducing general immunosuppression. In a prospective dose escalation study, we ...
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...