In:
Research, Society and Development, Research, Society and Development, Vol. 9, No. 8 ( 2020-07-31), p. e836986151-
Abstract:
A number of power quality issues including electrical harmonics, poor power factor, and voltage instability and imbalance impact on the efficiency of electrical equipment. To support that equipment operates optimally, electrical power is generated must be have good quality. This study has a purpose to examine the power quality of electrical system AHTS (Anchor Handling Tug Supply) vessel. This research was done by quantitative method. Computational techniques used by the software of Total Harmonic Distortion (THD), which shares characteristics and Electrochemical Impedance Spectroscopy (EIS). The result of this analysis indicated that Electrical system in VM INPOSH REGENT have quality power very good of utility systems during full way condition, however during maneuver, there was a particularly high harmonic from non-linier devices used as motor control, which functional a role propulsion. Based on the result above, it can be concluded that after filtering so that harmonic can correct until perimeter secure ABS standard, system is very good during maneuver long site and maneuver on DP system.
Type of Medium:
Online Resource
ISSN:
2525-3409
DOI:
10.33448/rsd-v9i8.6151
Language:
Unknown
Publisher:
Research, Society and Development
Publication Date:
2020