GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Institute of Physics Publishing (IOP)  (1)
  • Taylor & Francis  (1)
Document type
Publisher
Years
  • 1
    Publication Date: 2016-02-23
    Description: Sea ice leads play an essential role in ocean-ice-atmosphere exchange, in ocean circulation, geochemistry and in ice dynamics. Their precise detection is crucial for altimetric estimations of sea ice thickness and volume. This study evaluates the performance of the SARAL/AltiKa altimeter to detect leads and to monitor their spatio-temporal dynamics. We show that a pulse peakiness parameter (PP) used to detect leads by Envisat RA-2 and ERS-1,-2 altimeters is not suitable because of saturation of AltiKa return echoes over the leads. The signal saturation results in loss of 6–10% of PP data over sea ice. We propose a different parameter: maximal power of waveform, and define the threshold to discriminate the leads. Our algorithm can be applied from December until May. It detects well the leads of small and medium size: from 200 m to 3–4 km. So, the combination of the high-resolution altimetric estimates with low-resolution thermal infra-red or radiometric lead fraction products could enhance the capability of remote sensing to monitor sea ice fracturing.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2014-01-29
    Description: Petiroc and Citiroc are the two latest ASIC from Weeroc dedicated to SiPM read-out. Petiroc is a 16-channel front-end ASIC designed to readout silicon photomultipliers (SiPMs) for particle time-of-flight measurement applications. It combines a very fast and low-jitter trigger with an accurate charge measurement. Citiroc is a 32-channel front-end ASIC designed to readout silicon photo-multipliers (SiPM). It allows triggering down to 1/3 pe and provides the charge measurement with a good noise rejection. Moreover, Citiroc outputs the 32-channel triggers with a high accuracy (100 ps). Each channel of both ASICs combines a trigger path with an accurate charge measurement path. An adjustment of the SiPM high voltage is possible using a channel-by-channel input DAC. That allows a fine SiPM gain and dark noise adjustment at the system level to correct for the non-uniformity of SiPMs. Timing measurement down to 16 ps RMS jitter for Petiroc and 100 ps RMS for Ci...
    Electronic ISSN: 1748-0221
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...