GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1440
    Keywords: Na+/H+ antiport ; Hypertension ; Diabetic nephropathy ; Hereditary factors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The incidence of diabetic nephropathy in patients with insulin-dependent diabetes mellitus (IDDM) may depend on factors other than the quality of diabetes control. Hypertension is an additional factor associated with a high degree of renal involvement in IDDM. One abnormality consistantly observed in various tissues of patients with essential hypertension is enhanced activity of the Na+/H+ antiport. In the present study we have therefore studied platelet antiport activity in 41 healthy subjects (control), in 22 patients with untreated essential hypertension (EH), and in 35 normotensive IDDM patients (type 1). Of these patients 17 exhibited signs of diabetic nephropathy (group 1) while 18 had no evidence for renal involvement of IDDM in spite of a duration of IDDM of at least 10 years (group 2). The two IDDM patient groups were undistinguishable with respect to age, body mass index, and arterial blood pressure (group 1, 117.9±2.4/78.4±1.5 mmHg; group 2, 113.9±3.6/76.1±1.8 mmHg). Antiporter activity was determined from the rate of cell volume changes induced by propionic acid. Platelet Na+/H+ exchange activity averaged 23.43±0.43 10−3·s−1 in control subjects and was markedly elevated in EH (28.38±0.62 10−3·s−1 P〈0.01). Antiport activity in group 2 patients without nephropathy averaged 24.54±0.57 10−3·s−1 and was undistinguishable from the control group. However, platelet Na+/H+ antiport activity was significantly stimulated in group 1 patients with nephropathy as compared to group 2(26.95±0.73 10−3. s−1 ; P〈0.025). Our results show that renal involvement in IDDM is associated with enhanced activity of the platelet Na+/H+ antiport.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Nitrendipine ; Bisoprolol ; Hypertension ; self-measured blood pressure ; diurnal variation ; adverse effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary In a double-blind, placebo-controlled study the antihypertensive efficacy and tolerability of a single morning dose of either 10 mg bisoprolol (n=26) or 20 mg nitrendipine (n=27) were investigated. Blood pressure was measured by three techniques: (1) Casual blood pressure 24 h after the dose; (2) ambulatory 24-h whole-day monitoring; and (3) self-recorded blood pressure in the morning 24 h after the dose (6–8 a.m.) and in the evening (6–8 p.m.). After 4 weeks of therapy bisoprolol had produced a highly significant reduction in blood pressure as assessed by casual, ambulatory day- and night-time monitoring, and self-measured morning and evening readings. Bisoprolol was significantly more effective than nitrendipine, which did not induce a significant reduction in the ambulatory night-time recordings. Whole-day ambulatory blood pressure profiles showed an antihypertensive effect of bisoprolol throughout the entire 24-h period. 24-h blood pressure curves after nitrendipine demonstrated a markedly shorter duration of action, with no reduction in early morning blood pressure. Adverse effects and tolerability of the two drugs were comparable. The average changes in systolic and diastolic blood pressure after bisoprolol and nitrendipine in 2-h periods of ambulatory monitoring (6–8 a.m. and 6–8 p.m.) and self-measured blood pressure (6–8 a.m. and 6–8 p.m.) showed a good agreement between ambulatory and self-measured blood pressure determinations with no significant difference between the methods. The results show that 24 h antihypertensive efficacy was more pronounced for bisoprolol than for nitrendipine at the doses studied. Further, self-measured blood pressures at home were suitable for accurate estimation of the 12-h and 24-h antihypertensive efficacy of the two drugs. The methodological findings of this study have important implications for further pharmacological trials investigating the duration of action of antihypertensive drugs.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 72 (1994), S. 944-950 
    ISSN: 1432-1440
    Keywords: Hypertension ; Low density lipoprotein ; Apo B ; Cholesterol ; Very low density lipoprotein ; Triglycerides ; Lipoprotein (a)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In recent years there have been many studies demonstrating a correlation between increased arterial blood pressure and altered lipid profiles, and there has been an especially positive correlation between high cholesterol levels and blood pressure. There are differences between the various reports that are important. In our study the lipid distribution in 105 hypertensive patients with mild or moderate arterial hypertension according to WHO criteria without clinically or ultrasonographically apparent atherosclerosis was compared to the lipid distribution in 65 age-matched healthy persons. On the epidemiological level a significant, positive association was found between LDL serum levels (P ≤ 0.001), Apo B serum levels (P ≤ 0.001), serum triglyceride levels (P ≤ 0.05) and VLDL serum levels (P ≤ 0.01) and arterial hypertension. However, in contrast to recent reports, no significant difference was found between total serum cholesterol levels in normotensives and hypertensives, and there was no difference in HDL serum levels. No evidence could be found for a significant increase in lipoprotein (a) serum levels in hypertensives.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemical Engineering & Technology - CET 15 (1992), S. 300-312 
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry and Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Thick-walled components subjected to pulsating internal pressure are widely applied in high-pressure technology and in manufacturing processes such as fluid-jet cutting and high-pressure cleaning, mainly in conjunction with reciprocating pumps. Corrosive fluids require high-strength and tough chrome-nickel steels with soft martensitic or semi-austenitic structure. This contribution reports on the fatigue of thick-walled plain and cross-bored pipes made from high alloy chrome-nickel steels such as X5 CrNiMoCu 21 8 and X5 CrNiMo 16 5. The speciments, uniaxial standard form and thick-walled pipes, were cut from forged blocks in the three axial directions. For loading with pulsating pressure, a suitable, high-frequency piston pulsation machine has been developed. The fatigue tests on pipe specimens show typical Woehler characteristics with only slight scatter and relatively good isotropy. The surprisingly large admissible pulsating pressure can be explained for the applied steels by dynamic generation of residual stresses as a result of shake-down effects. Presentation in a Smith digram explains the occuring dynamic shake-down and its favourable results in comparison to the more brittle highly tensile steels. It also reveals that heat treatment to higher tensile strength does not always yield an increase in the admissible pulsating pressure. It will be shown that static autofretting and shake-down affect the fatigue strength of thick-walled pipe specimens in the same way. Tests with internal liners in the tube specimens provide indications on the sensitivity of material failures towards fluids. The investigation aids the understanding of the fatigue behaviour and the design of components made of modern high-strength corrosion resistant steels.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry and Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Titanium silicalite-1 samples of different particle size are synthesised and characterised by X-ray diffraction (XRD), photoelectron spectroscopy (XPS), diffuse reflectance spectroscopy (DRS), Raman and infrared spectroscopy. Size histograms are taken from transmission electron micrographs. Temporal changes of activity and selectivity for the hydroxylation of phenol and anisole are monitored. It is postulated that the p/o product ratios are due to the greater chemisorption of the ortho molecule.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 851-858 
    ISSN: 0935-6304
    Keywords: High resolution gas chromatography ; Chlorinated hydrocarbons ; Polychlorinated biphenyls ; PCB indicator congeners ; Coelution ; Toxic PCB congeners ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Eighty one polychlorinated biphenyls (PCBs) and nineteen chlorinated pesticide standards have been analyzed on a newly developed apolar high resolution gas chromatography (HRGC) column. Emphasis was placed on the determination of PCB indicator congeners which are part of national regulations, and of toxic coplanar PCB congeners.The new column enables almost unambiguous quantification of the PCB indicator congeners (PCB 138 can be separated from both PCB 163 and PCB 164; PCB 28 and PCB 31 were also separated and no coelution was observed for PCB 52, PCB 118, and PCB 180). The new column furnished better results than CP-Sil 8 for the analysis of PCB indicator congeners in a sample of seal blubber.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1040-7685
    Keywords: capillary gas chromatography ; capillary supercritical fluid chromatography ; enantiomeric alcohols ; diastereomeric esters ; Trolox methyl ether ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The enantiomers of aliphatic alcohols are transformed by a new chiral reagent (S)-Trolox methyl ether to their diastereomeric esters which are separated by capillary GC or SFC on achiral columns. The applicability of this reagent and its superiority to the hitherto known reagents are demonstrated by selected examples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 23 (1994), S. 379-379 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0009-286X
    Keywords: Dosieren ; Schüttguttechnik ; Schneckendosierer ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 65 (1993), S. 1088-1090 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...