GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 3 (1993), S. 143-146 
    ISSN: 1432-1068
    Keywords: Knee prostheses ; Prothèses de genou
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Les auteurs rapportent une expérience homogène de 10 ans d'une prothèse totale de genou cimentée semi-contrainte en acier inoxydable 316 L coulé et coussin tibial amovible en polyéthylène. Sur 68 patients opérés, 50 ont pu être suivis avec un recul moyen de 6 ans. Les résultats obtenus, selon le score 100 points, sont sensiblement comparables à ceux publiés dans la Littérature pour ce type de prothèse avec 84 % de malades entre 80 et 100 et un indice de satisfaction positif dans 94 % des cas. Toutefois, il est noté sur le plan anatomique une fréquence non négligeable de défauts de positionnement (5 %) et sur le plan fonctionnel, 40 % des cas présentent un sentiment d'insécurité à la descente des escaliers. Cette insécurité est liée principalement à des problèmes techniques en rapport avec un ancillaire très approximatif à l'époque étudiée et qui est maintenant amélioré. Malgré ses résultats relativement moyens, ce type de prothèse, en raison de sa facilité et rapidité de mise en place, doit encore trouver des indications chez des malades de grand âge aux exigences physiques modestes.
    Notes: Abstract The authors report an homogeneous series over ten years of a cemented total prosthesis of the knee, semi-constraint, in a stainless steel, 316 L cast, and a removable tibial cushion in polyethylene. On 68 patients operated on, 50 have been followed up with an average follow-up of 6 years. The results obtained, allowing a score of 100 points, are comparable to those published in the literature for this type of prosthesis, with 84 % of patients between 80 and 100, and a positive index of satisfaction in a 94 % of cases. Nevertheless, from an anatomical point of view, we noticed a non negligible frequency of a defect in position (5%) and from a fonctional point of view, 40% of the patients have a feeling of insecurity in going down steps. This feeling of insecurity is particulary linked to technical problems in relation with the instrumentation, very approximate at the time it was studied, and which is now improved. In spite of its average results, this type of prosthesis, thanks to its ease and speed of placement, must find some indications for elderly people with a modest requirements.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...