GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Korean Society of Environmental Engineering ; 2021
    In:  Journal of Korean Society of Environmental Engineers Vol. 43, No. 10 ( 2021-10-31), p. 654-663
    In: Journal of Korean Society of Environmental Engineers, Korean Society of Environmental Engineering, Vol. 43, No. 10 ( 2021-10-31), p. 654-663
    Abstract: Objectives : This article provides a comparative analysis of boron removal for brackish water reverse osmosis (BWRO), boron selective ion exchange (IX), or capacitive deionization (CDI) processes. Permeate of 1st-Pass RO process has to be post-treated for additional boron removal. Hence, we experimentally analyzed the performance of boron removal and specific energy consumption (SEC) of three aforementioned processes and investigated whether the processes are suitable for 2nd pass process of RO desalination.Methods : Raw feed water was prepared using NaCl and B(OH)3. Semi-pilot scale RO and IX systems (over 1 m3/hr capacity) and bench scale CDI system (over 2.5 L/min) were tested for performance comparison. Boron concentration was measured using Azomethine-H method for feed and product water. Energy consumption was monitored by using power quality analyzer.Results and Discussion : Each process has its own operating conditions. The RO process required high pH of feed water for high boron removal rate, the IX process was operated below breakthrough point considering adsorption capacity of boron selective resin, and the CDI process didn’t remove boron because chloride ion has higher ion selectivity for carbon electrode than boron. In terms of SEC, the pressure-driven RO process showed the highest SEC among three processes. The CDI process based on electrical adsorption of carbon electrode showed a considerable energy consumption as well. On the other hand, the IX process was operated at low energy consumption because its removal is just based on adsorption-desorption mechanism.Conclusions : The RO and CDI processes have received a lot of attention as leading and emerging technology while the IX process was regarded as a stubborn process because of regeneration of resin and its several segmentalized steps. However, we found that the IX process has a better performance for boron removal and energy consumption.
    Type of Medium: Online Resource
    ISSN: 1225-5025 , 2383-7810
    Language: English
    Publisher: Korean Society of Environmental Engineering
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...