GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    American Society of Tropical Medicine and Hygiene ; 2017
    In:  The American Journal of Tropical Medicine and Hygiene Vol. 97, No. 6 ( 2017-12-06), p. 1836-1842
    In: The American Journal of Tropical Medicine and Hygiene, American Society of Tropical Medicine and Hygiene, Vol. 97, No. 6 ( 2017-12-06), p. 1836-1842
    Abstract: The World Health Organization’s Global Program to Eliminate Lymphatic Filariasis (LF) has reduced LF transmission worldwide, but millions remain affected by filarial lymphedema. Tools for clinically monitoring lymphedema in developing nations are limited. We tested a novel, portable, infrared three-dimensional imaging system (3DIS) against water displacement (WD) and tape measurement of limb circumference (TMLC) among patients with filarial leg lymphedema in Galle, Sri Lanka. Outcomes were accuracy and reproducibility of imaging system measurements. In parallel, we also tested the reproducibility of skin thickness ultrasound (STU) measurements. We examined 52 patients (104 limbs) with lymphedema of stages 0–6 ( N = 28, 19, 20, 21, 2, 4, and 10, respectively). 3DIS measurements correlated nearly perfectly with WD ( r 2 = 0.9945) and TMLC values ( r 2 〉 0.9801). The median time required to acquire imaging system measurements for both legs was 2.1 minutes, compared with 17, 7, and 29 minutes, respectively, for WD, TMLC, and STU. Median interexaminer coefficients of variation (CVs) for volume measurements were 1.1% (interquartile range [IQR] 0.5–2.1%) for WD and 1.7% (IQR 1.2–2.4%) for the 3DIS. CVs for circumference measurements were 1.4% (IQR 0.8–2.4%) by TMLC and 1.3% (0.8–1.9%) by 3DIS. Median interexaminer CV for STU was 13.7% (IQR 8.5–21.3%). The portable imaging system noninvasively provided accurate and reproducible limb volume and circumference measurements in approximately 2 minutes per patient. This portable technology has the potential to greatly improve assessment and monitoring of lymphedema in the clinic and in the field.
    Type of Medium: Online Resource
    ISSN: 0002-9637 , 1476-1645
    Language: Unknown
    Publisher: American Society of Tropical Medicine and Hygiene
    Publication Date: 2017
    detail.hit.zdb_id: 2942-7
    detail.hit.zdb_id: 1491674-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...