GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Walter de Gruyter GmbH ; 2013
    In:  Clinical Chemistry and Laboratory Medicine (CCLM) Vol. 51, No. 4 ( 2013-04-01), p. 863-872
    In: Clinical Chemistry and Laboratory Medicine (CCLM), Walter de Gruyter GmbH, Vol. 51, No. 4 ( 2013-04-01), p. 863-872
    Abstract: Background: Determination of pediatric reference intervals (RIs) for laboratory quantities, including hematological quantities, is complex. The measured quantities vary by age, and obtaining samples from healthy children is difficult. Many widely used RIs are derived from small sample numbers and are split into arbitrary discrete age intervals. Use of intra-laboratory RIs specific to the examined population and analytical device used is not yet fully established. Indirect methods address these issues by deriving RIs from clinical laboratory databases which contain large datasets of both healthy and pathological samples. Methods: A refined indirect approach was used to create continuous age-dependent RIs for blood count quantities and sodium from birth to adulthood. The dataset for each quantity consisted of 60,000 individual samples from our clinical laboratory. Patient samples were separated according to age, and a density function of the proportion of healthy samples was estimated for each age group. The resulting RIs were merged to obtain continuous RIs from birth to adulthood. Results: The obtained RIs were compared to RIs generated by identical laboratory instruments, and to population-specific RIs created using conventional methods. This comparison showed a high concordance of reference limits and their age-dependent dynamics. Conclusions: The indirect approach reported here is well-suited to create continuous, intra-laboratory RIs from clinical laboratory databases and showed that the RIs generated are comparable to those created using established methods. The procedure can be transferred to other laboratory quantities and can be used as an alternative method for RI determination where conventional approaches are limited.
    Type of Medium: Online Resource
    ISSN: 1437-4331 , 1434-6621
    Language: English
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2013
    detail.hit.zdb_id: 1492732-9
    SSG: 15,3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...