GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Reproductive Biology and Endocrinology, Springer Science and Business Media LLC, Vol. 22, No. 1 ( 2024-05-22)
    Abstract: Deep learning has been increasingly investigated for assisting clinical in vitro fertilization (IVF). The first technical step in many tasks is to visually detect and locate sperm, oocytes, and embryos in images. For clinical deployment of such deep learning models, different clinics use different image acquisition hardware and different sample preprocessing protocols, raising the concern over whether the reported accuracy of a deep learning model by one clinic could be reproduced in another clinic. Here we aim to investigate the effect of each imaging factor on the generalizability of object detection models, using sperm analysis as a pilot example. Methods Ablation studies were performed using state-of-the-art models for detecting human sperm to quantitatively assess how model precision (false-positive detection) and recall (missed detection) were affected by imaging magnification, imaging mode, and sample preprocessing protocols. The results led to the hypothesis that the richness of image acquisition conditions in a training dataset deterministically affects model generalizability. The hypothesis was tested by first enriching the training dataset with a wide range of imaging conditions, then validated through internal blind tests on new samples and external multi-center clinical validations. Results Ablation experiments revealed that removing subsets of data from the training dataset significantly reduced model precision. Removing raw sample images from the training dataset caused the largest drop in model precision, whereas removing 20x images caused the largest drop in model recall. by incorporating different imaging and sample preprocessing conditions into a rich training dataset, the model achieved an intraclass correlation coefficient (ICC) of 0.97 (95% CI: 0.94-0.99) for precision, and an ICC of 0.97 (95% CI: 0.93-0.99) for recall. Multi-center clinical validation showed no significant differences in model precision or recall across different clinics and applications. Conclusions The results validated the hypothesis that the richness of data in the training dataset is a key factor impacting model generalizability. These findings highlight the importance of diversity in a training dataset for model evaluation and suggest that future deep learning models in andrology and reproductive medicine should incorporate comprehensive feature sets for enhanced generalizability across clinics.
    Type of Medium: Online Resource
    ISSN: 1477-7827
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2024
    detail.hit.zdb_id: 2119215-7
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...