GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2020
    In:  BMC Cardiovascular Disorders Vol. 20, No. 1 ( 2020-12)
    In: BMC Cardiovascular Disorders, Springer Science and Business Media LLC, Vol. 20, No. 1 ( 2020-12)
    Abstract: Longitudinal stent deformation (LSD) is an infrequent complication of percutaneous coronary intervention (PCI), and it may lead to catastrophic clinical outcomes. However, reports of cardiac adverse events associated with LSD are rare. Case presentation A 55-year-old man with chest pain was treated for a severe left anterior descending branch (LAD)-diagonal 1 (D1) bifurcation lesion by PCI with two stents in the proximal LAD. LSD occurred during the withdrawal of the trapped D1 wire. High-pressure balloon dilatation was performed in the deformed stent, and the end-angiographic appearance was acceptable, but no additional corrective measures were implemented. Ten months later, the patient represented with acute coronary syndrome. Severe in-stent restenosis (ISR) had suboccluded the proximal LAD, and optical coherence tomography (OCT) visualized multilayered stent struts protruding into the lumen at the compressed segment of the stent. Following complete apposition with balloon dilation, a drug-coated balloon (DCB) was used to avoid an additional permanent metallic layer. He remained angina free, and the angiographic result demonstrated no residual stenosis at the six-month follow-up. To our knowledge, this case demonstrates the first report of ISR triggered by LSD in patients treated with DCBs under the guidance of OCT. Conclusions The current report underscores the importance of awareness of LSD, and OCT seems to be the preferred modality to confirm complete apposition. If left without performing additional corrective measures, LSD may be associated with a risk of ISR. Complete apposition with balloon dilation followed by a DCB is a feasible treatment option.
    Type of Medium: Online Resource
    ISSN: 1471-2261
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2020
    detail.hit.zdb_id: 2059859-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...