In:
Technology in Cancer Research & Treatment, SAGE Publications, Vol. 7, No. 1 ( 2008-02), p. 27-33
Abstract:
In this study we sought to assess the potential of the respiratory tumor tracking system of the CyberKnife to administer 3 fractions of 15 Gy in the treatment of early stage non-small cell lung cancer (NSCLC). The CyberKnife plans were compared to those developed for 3-D conformal radiotherapy (3-D CRT) administering 20 fractions of 3 Gy based on a slow CT. Ten patients with stage I NSCLC, who were previously treated with 3-D CRT, were re-planned with the CyberKnife treatment planning system. In the 3-D CRT plan, the planning target volume (PTV) included the gross tumor volume (GTV) slow and a 15-mm margin, whereas in the CyberKnife plan the margin was 8 mm. The physical doses from both treatment plans were converted to normalized total doses (NTD) using the linear quadratic model with an α/β tumor of 10 Gy and α/β organs at risk (OAR) of 3 Gy. The average minimal and mean doses administered to the PTV with the CyberKnife and 3-D CRT were 93 and 115.8 Gy and 61 and 66 Gy, respectively (p 〈 0.0001). The mean V 20 of the CyberKnife and 3-D CRT plans were 8.2% and 6.8%, respectively (p=0.124). Both plans complied with the OAR constraints. In conclusion, 4-dimensional stereotactic radiotherapy can increase the minimal and mean biological dose with 51% and 75%, in comparison with 3-D CRT without significantly increasing the V 20 , respectively.
Type of Medium:
Online Resource
ISSN:
1533-0346
,
1533-0338
DOI:
10.1177/153303460800700103
Language:
English
Publisher:
SAGE Publications
Publication Date:
2008