GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 1998
    In:  Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis Vol. 18, No. 5 ( 1998-09), p. 497-504
    In: Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, SAGE Publications, Vol. 18, No. 5 ( 1998-09), p. 497-504
    Abstract: To assess the clearance of radiolabeled tracer albumin (RISA) from peritoneal cavity to plasma (CI → P) in rats under essentially “normal” conditions, that is, when intraperitoneal hydrostatic pressure (IPP) is subatmospheric and the intraperitoneal (IP) “free” fluid volume (IPV) is low. Methods A volume of 0.3 mL of RISA was injected IP into anesthetized Wistar rats (wt = 300 g) when the IPV was approximately 2 mL (normal) or the IPV was approximately 10 mL, and IPP was either -1.8 mmHg (normal) or +1.5 mmHg (produced by an external cuff). Plasma samples (25 μL) were obtained repeatedly during the dwell, which lasted 30 300 min, after which the peritoneal cavity was opened to recover the IPV and residuallP RISA activity. The CI → P was assessed as the mass transfer of RISA into plasma, occurring per unit time,-divided by the calculated mean IP RISA concentration (CD). The interstitial RISA space was measured as the mass of RISA accumulated, per unit tissue weight, in peritoneal tissue samples divided by the CD. Results A markedly lower CI → P (2.47 ± 0.67 μL/min), as well as total RISA clearance out of the peritoneal cavity (CI), was found under “normal” conditions (an IPV of approximately 2 mL and an IPP of approximately -1.8 mmHg) compared to the situation during peritoneal dialysis (an IPV of approximately 20 mL and an IPP of +1 mmHg). Furthermore, the interstitial RISA space increased linearly over time even at negative IPPs and at an unchanging peritoneal interstitial fluid volume. At a low (normal) IPV the CI → P did not increase significantly with elevating IPP, and increased only marginally when tracer distribution was improved by artificial vibration of the rats. However the CI → P increased when larger volumes were infused to increase the totallPV. Conclusions It is concluded that the CI → P and CI at low IPPs and IPVs are not as high as during peritoneal dialysis. Increases in CI → P were, however, coupled to increases in IPV. This highlights the importance of the IPV per se and of a sufficient IP tracer distribution for direct lymphatic absorption to be efficient. This study was presented in part at the XVIth Annual Conference on Peritoneal Dialysis, Denver, Colorado, U.S.A., 1997 (33).
    Type of Medium: Online Resource
    ISSN: 0896-8608 , 1718-4304
    Language: English
    Publisher: SAGE Publications
    Publication Date: 1998
    detail.hit.zdb_id: 2075957-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...