GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2019
    In:  Acta Radiologica Vol. 60, No. 4 ( 2019-04), p. 526-534
    In: Acta Radiologica, SAGE Publications, Vol. 60, No. 4 ( 2019-04), p. 526-534
    Abstract: Recently, histogram analysis based on voxel-wise apparent diffusion coefficient (ADC) value distribution has been increasingly performed. However, few studies have been reported regarding its repeatability. Purpose To evaluate the repeatability of ADC histogram metrics of the uterus in clinical magnetic resonance imaging (MRI). Material and Methods Thirty-three female patients who underwent pelvic MRI including diffusion-weighted imaging (DWI) were prospectively included after providing informed consent. Two sequential DWI acquisitions with identical parameters and position were obtained. Regions of interest (ROIs) for histologically confirmed uterine lesions (five cervical and three endometrial cancers, and one endometrial hyperplasia) and normal appearing tissues (21 endometrium and 33 myometrium) were assigned on the first DWI dataset and then pasted onto the second DWI dataset. ADC histogram metrics within the ROIs were calculated and repeatability was evaluated by calculating within-subject coefficient of variance (%) (wCV (%)) and Bland–Altman plot (%). Results ADC 10%, 25%, median, 75%, 90%, maximum, mean, and entropy showed high repeatability (wCV (%)  〈  7, 95% limit of agreement in Bland–Altman plot (%)  〈  ±20), followed by ADC minimum (wCV (%) = 8.12, 95% limit of agreement in Bland–Altman plot (%)  〈  ±30). However, ADC skewness and kurtosis showed very low repeatability in all evaluations. Conclusion ADC histogram metrics like ADC 10%, 25%, median, 75%, 90%, maximum, mean, and entropy are robust biomarkers and could be applicable to clinical use. However, ADC skewness and kurtosis lack robustness. Radiologists should keep these characteristics and limitations in mind when interpreting quantitative DWI.
    Type of Medium: Online Resource
    ISSN: 0284-1851 , 1600-0455
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2019
    detail.hit.zdb_id: 2024579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...