GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2021
    In:  Journal of the Chinese Medical Association Vol. 84, No. 11 ( 2021-11), p. 1038-1047
    In: Journal of the Chinese Medical Association, Ovid Technologies (Wolters Kluwer Health), Vol. 84, No. 11 ( 2021-11), p. 1038-1047
    Abstract: Medial displacement calcaneal osteotomy (MDCO) is frequently used for the surgical correction of flatfoot. This study aims to investigate the biomechanical effect of the different diagonal screw design on a novel-designed embedded calcaneal plate for MDCO using finite element analysis (FEA), mechanical test and digital image correlation (DIC) measurement. Methods: Four groups according to the varied implanted plate were set as control group (Group 1), non-diagonal screw (Group 2), one-diagonal screw (Group 3), and two-diagonal screws groups (Group 4). For FEA, A 450 N load was applied to on the anterior process of the calcaneus from top to bottom. Observational indices included the stress on the cortical and cancellous bone of the calcaneus surrounding the implant, the plate itself as well as screws, and the displacement of the overall structure. In addition, this study also used in vitro biomechanics test to investigate the stiffness of the structure after implantation, and used DIC to observe the displacement of the calcaneus structure after external force. Results: Under a simulated load in FEA, there are significant overall instability and high stress concentration on the calcaneal surrounding host bone and the plate/screws system, respectively, in group 2 compared with other groups. Regard to the mechanical testing with DIC system, significant increased rotation stability, maximum force and stiffness with the addition of diagonal screws. In comparison to Group 2, the increase of 112% and 157% in maximum force as well as 104% and 176% in stiffness were found in Group 3 and 4, respectively. Conclusion: For reducing stress concentration and enhancing overall stability, more than one-diagonal screw design is recommended and two-diagonal screws design will be superior. This study provided biomechanical references for further calcaneal implants design to prevent clinical failure after MDCO.
    Type of Medium: Online Resource
    ISSN: 1726-4901
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2202774-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...