GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2023
    In:  Health Physics Vol. 125, No. 2 ( 2023-8), p. 123-136
    In: Health Physics, Ovid Technologies (Wolters Kluwer Health), Vol. 125, No. 2 ( 2023-8), p. 123-136
    Abstract: We developed a new method for simultaneous determination of 89 Sr and 90 Sr with an emphasis on detectability. The samples were digested, and Sr was chemically purified followed by a single count on a liquid scintillation counter in three windows overlapping the 90 Sr, 89 Sr, and 90 Y peaks. Gamma spectrometry was used to measure 85 Sr, added for chemical recovery. The method was tested on 18 water samples spiked at levels from 9 to 242 Bq of 89 Sr and 90 Sr, with either single radionuclides or their mixtures. In addition, eight method blanks were measured. The data were analyzed numerically by solving a system of linear equations for 89 Sr and 90 Sr activities as analytes and 90 Y activity as a participating component. The total uncertainties of the results were calculated numerically using variances and covariances. The average bias from the known activities was −0.3% (range from −3.6 to 3.1%) for 90 Sr and − 1.5% (range from −10.1 to 5.1%) for 89 Sr. The En -scores were within −1.0 and 1.0 at 95% confidence level. The detection capabilities of this method were determined by means of the decision threshold LC and the limit of detection referred to as the minimum detectable activity. All relevant uncertainties were propagated into the LC and minimum detectable activity. In addition, detection limits were calculated for the purpose of Safe Drinking Water Act monitoring. The detection capabilities were compared with the regulatory requirements in the US and EU for food and water. For samples spiked with either pure 89 Sr or 90 Sr, false positives were observed for the opposite radionuclide exceeding the above LC values. This was attributed to interference by the spiked activity. A new method was developed to calculate decision and detectability curves in the presence of interference.
    Type of Medium: Online Resource
    ISSN: 1538-5159 , 0017-9078
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...