GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Dalton Transactions, Royal Society of Chemistry (RSC), Vol. 51, No. 24 ( 2022), p. 9541-9555
    Abstract: Ligands combining a bis(phosphonate) group with a macrocycle function as metal isotope carriers for radionuclide-based imaging and for treating bone metastases associated with several cancers. However, bis(phosphonate) pendant arms often slow down complex formation and decrease radiochemical yields. Nevertheless, their negative effect on complexation rates may be mitigated by using a suitable spacer between bis(phosphonate) and the macrocycle. To demonstrate the potential of bis(phosphonate) bearing macrocyclic ligands as a copper radioisotope carrier, we report the synthesis of a new cyclam derivative bearing a phosphinate-bis(phosphonate) pendant (H 5 te1P BP ). The ligand showed a high selectivity to Cu II over Zn II and Ni II ions, and the bis(phosphonate) group was not coordinated in the Cu II complex, strongly interacting with other metal ions in solution. The Cu II complex formed quickly, in 1 s, at pH 5 and at a millimolar scale. The complexation rates significantly differed under a ligand or metal ion excess due to the formation of reaction intermediates differing in their metal-to-ligand ratio and protonation state, respectively. The Cu II -te1P BP complex also showed a high resistance to acid-assisted hydrolysis ( t 1/2 2.7 h; 1 M HClO 4 , 25 °C) and was effectively adsorbed on the hydroxyapatite surface. H 5 te1P BP radiolabeling with [ 64 Cu]CuCl 2 was fast and efficient, with specific activities of approximately 30 GBq 64 Cu per 1 μmol of ligand (pH 5.5, room temperature, 30 min). In a pilot experiment, we further demonstrated the excellent suitability of [ 64 Cu]Cu II -te1P BP for imaging active bone compartments by dedicated small animal PET/CT in healthy mice and subsequently in a rat femoral defect model, in direct comparison with [ 18 F]fluoride. Moreover, [ 64 Cu]Cu II -te1P BP showed a higher uptake in critical bone defect regions. Therefore, our study highlights the potential of [ 64 Cu]Cu II -te1P BP as a PET radiotracer for evaluating bone healing in preclinical and clinical settings with a diagnostic value similar to that of [ 18 F]fluoride, albeit with a longer half-life (12.7 h) than 18 F (1.8 h), thereby enabling extended observation times.
    Type of Medium: Online Resource
    ISSN: 1477-9226 , 1477-9234
    Language: English
    Publisher: Royal Society of Chemistry (RSC)
    Publication Date: 2022
    detail.hit.zdb_id: 2001339-5
    detail.hit.zdb_id: 1472887-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...