GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: NMR in Biomedicine, Wiley, Vol. 32, No. 9 ( 2019-09)
    Abstract: Structural high‐resolution imaging of the brainstem can be of high importance in clinical practice. However, ultra‐high field magnetic resonance imaging (MRI) is still restricted in use due to limited availability. Therefore, quantitative MRI techniques (quantitative susceptibility mapping [QSM], relaxation measurements [ , R 1 ], diffusion tensor imaging [DTI] ) and T 2 ‐ and proton density (PD)‐weighted imaging in the human brainstem at 3 T and 7 T are compared. Five healthy volunteers (mean age: 21.5 ± 1.9 years) were measured at 3 T and 7 T using multi‐echo gradient echo sequences for susceptibility mapping and relaxometry, magnetization‐prepared 2 rapid acquisition gradient echo sequences for R 1 relaxometry, turbo‐spin echo sequences for PD‐ and T 2 ‐weighted imaging and readout‐segmented echo planar sequences for DTI. Susceptibility maps were computed using Laplacian‐based phase unwrapping, V‐SHARP for background field removal and the streaking artifact reduction for QSM algorithm for dipole inversion. Contrast‐to‐noise ratios (CNRs) were determined at 3 T and 7 T in ten volumes of interest (VOIs). Data acquired at 7 T showed higher CNR. However, in four VOIs, lower CNR was observed for at 7 T. QSM was shown to be the contrast with which the highest number of structures could be identified. The depiction of very fine tracts such as the medial longitudinal fasciculus throughout the brainstem was only possible in susceptibility maps acquired at 7 T. DTI effectively showed the main tracts (crus cerebri, transverse pontine fibers, corticospinal tract, middle and superior cerebellar peduncle, pontocerebellar tract, and pyramid) at both field strengths. Assessing the brainstem with quantitative MRI methods such as QSM, , as well as PD‐ and T 2 ‐weighted imaging with great detail, is also possible at 3 T, especially when using susceptibility mapping calculated from a gradient echo sequence with a wide range of echo times from 10.5 to 52.5 ms. However, tracing smallest structures strongly benefits from imaging at ultra‐high field.
    Type of Medium: Online Resource
    ISSN: 0952-3480 , 1099-1492
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2019
    detail.hit.zdb_id: 2002003-X
    detail.hit.zdb_id: 1000976-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...