GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Journals
  • Articles  (3)
  • ddc:690  (3)
  • English  (3)
Document type
  • Journals
  • Articles  (3)
Keywords
Language
  • English  (3)
Years
  • 1
    Publication Date: 2022-02-18
    Description: The potential of mixed-mode office buildings with varying design and control parameters is examined by using an uncertainty analysis in the three climate zones of India. The analysis is in terms of cooling energy consumption, thermal comfort conditions, and natural ventilation hours. Furthermore, influential parameters are identified using sensitivity analysis. In this study, opening the windows enables natural ventilation. Night-time ventilation through the windows is not enabled because these are mostly closed at night. A maximum natural ventilation of 10% of the total building occupancy hours are observed in warm and humid, and hot and dry climates; however, they are slightly higher in the composite climate. A further increase in the number of natural ventilation hours leads to an increase in the occupancy hours outside the Indian Model for Adaptive Comfort model for mixed-mode buildings with at least 90% of occupants are satisfied. There are no occupancy hours outside of 80% of occupants are satisfied. The choice of thermal comfort band is crucial for determining the potential of mixed-mode buildings. The cooling setpoint temperature, building size, window solar heat gain coefficient, and surface properties of exterior surfaces are identified as the more influential parameters than the thermophysical properties of building envelope constructions. Although the building envelope which is in compliance with the Energy Efficient Building Code of India increases energy efficiency during air-conditioning periods, whether it reduces natural ventilation hours, because of overheating during such period remains to be determined.
    Keywords: ddc:690
    Repository Name: Wuppertal Institut für Klima, Umwelt, Energie
    Language: English
    Type: article , doc-type:article
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2023-12-22
    Description: Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space cooling. However, there is little empirical evidence on the energy savings from using ceiling fans with Room Air-Conditioners (RACs). To address this gap, we analysed the energy performance of RACs with both fixed-speed compressors and inverter technology at different set-point temperatures and ceiling fan speed settings in 15 residential Mixed-Mode Buildings (MMBs) in India. Thermal comfort conditions (as predicted by the Indian Model for Adaptive Comfort-Residential (IMAC-R)) with minimum energy consumption were maintained at a set-point temperature (𝑇set) of 28 and 30 C and a fan speed setting of one. Compared with a Tset of 24 °C, a 𝑇set of 28 and 30 °C resulted in energy savings of 44 and 67%, respectively. With the use of RACs, a configuration with a minimum fan speed was satisfactory for an optimal use of energy and for maintaining the conditions of thermal comfort. In addition, RACs with inverter technology used 34-68% less energy than fixed-speed compressors. With the rising use of RACs, particularly in tropical regions, the study's outcomes offer a significant potential for reducing space-cooling energy consumption and the resultant greenhouse gas (GHG) emissions.
    Keywords: ddc:690
    Repository Name: Wuppertal Institut für Klima, Umwelt, Energie
    Language: English
    Type: article , doc-type:article
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2022-09-29
    Description: Vernacular architecture's use of passive building techniques has been developed in response to the prevailing climatic conditions of the past. Today, buildings are designed with complete indifference to the climate and materials. Energy consumption in buildings is mainly connected to space cooling, supply of hot water, lighting, cooking and, use of appliances. Space cooling and lighting are directly influenced by the design of the building. Energy codes should be concerned with "sufficiency" as well as "efficiency". A more economic and ecological approach to building design is needed.
    Keywords: ddc:690
    Repository Name: Wuppertal Institut für Klima, Umwelt, Energie
    Language: English
    Type: article , doc-type:article
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...