Abstract
The response of a single mode CO2 laser to modulation of pump, loss, and cavity length based on the vibro-rotational model is analysed and compared with similar analyses for the two-level rate equation model for laser action.
Similar content being viewed by others
References
Goswami B.K., Biswas D.J.: Phys. Rev. A.36, 975 (1987)
Gao J.Y., Zhang H.Z., Guo X.Z., Jin G.X., Abraham N.B.: Phys. Rev. A.40, 6339 (1989)
Cheo P.K., Abrams R.L.: Appl. Phys. Lett.,14, 47 (1969)
Arimondo E., Casagrande F., Lugiato L.A., Glorieux P.: Appl. Phys. B30, 57 (1983)
Tachikawa M., Tanii K., Kajita M., Shimizu T.: Appl. Phys.B 39, 83 (1986)
Arecchi F.T., Gadomski W., Meucci R., Roversi J.A.: Opt. Commun.65, 47 (1988)
Oppo G.L., Tredicce J.R., Narducci L.M.: Opt. Commun.69, 393 (1989)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zhang, H.Z., Gao, J.Y. Response to modulation of parameters in the vibro-rotational model for a CO2 laser. Z Phys D - Atoms, Molecules and Clusters 22, 511–515 (1992). https://doi.org/10.1007/BF01426092