Skip to main content
Log in

An operational amplifier 4-electrode impedance bridge for electrolyte measurements

  • Published:
Medical and biological engineering Aims and scope Submit manuscript

Abstract

A 4-electrode electronic half bridge which utilises solid-state operational amplifiers is described. This system, because of its extremely high input impedance, virtually eliminates the effects of a.c. electrode polarisation impedance in the measurements of the electrical properties of electrolytes. The system finds application in a.c. biological impedance spectroscopy.

Sommaire

Un demi pont électronique à 4 électrodes utilisant des amplificateurs operationnel transistorisés est décrit. Le système, à cause de son impédance d'entrée élevée, élimine pratiquement les effets d'impédance de polarisation d'électrode à courant alternatif lors de la mesure des propriétés d'électrolytes. Le système a des applications en spectroscopie d'impédance biologique à courant alternatif.

Inhaltsangabe

Eine elektronische 4-Elektroden-Halbbrücke, welche Festkörper-Operations-verstärker benutzt, wird beschrieben. Wegen seiner extrem hohen Eingangsimpedanz beseitigt das System praktisch alle Auswirkungen der Polarisationsimpedanz von Wechselspannungs-elektroden bei Messungen der elektrischen Eigenschaften von Elektrolyten. Das System wird in der biologischen Wechselspannungsimpedanz-Spektroskopie angewandt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ferris, C. D. (1963) Four-electrode electronic bridge for electrolyte impedance determinations.Rev. Sci. Instrum. 34, 109–111.

    Article  Google Scholar 

  • Ferris, C. D. andMellman, S. (1967). Nonlinear behaviour of a-c electrode polarization impedance.Proc. 20th ACEMB, p.15.3, Boston.

  • Ferris, C. D. (1969) Metallic electrodes.Conf. Record, 6th Ann. RMBS, 5–9, Laramie.

  • Hill, P. L. andSchwan, H. P. (1966) Observations on four-electrode impedance measurements.Proc. 19th ACEMB, p.2.6, San Francisco.

  • Hill, P. L. andSchwan, H. P. (1968) Relative performance of different four-electrode bridges.Proc. 21st ACEMB, p. 19.7, Houston.

  • Hill, R. V., Jansen, J. C., andFling, J. L. (1967) Electrical impedance plethysmography: a critical analysis.J. Appl. Physiol. 22, 161–168.

    Google Scholar 

  • Jaron, D., Schwan, H. P., andGeselowitz, D. B. (1967) A mathematical model for the polarization impedance of cardiac pacemaker electrodes.Proc. 20th ACEMB, p. 15.2, Boston.

  • Rose, D. R. (1970) Low frequency electrolyte impedance determinations by four-electrode electronic bridge technique. MS Thesis, Bioengineering, University of Wyoming, Laramie.

    Google Scholar 

  • Schwan, H. P. (1963) Determinations of biological impedance. InPhysical techniques in biological research, Ed. Nastuk, W. L. Chap. 6 Pt. B, pp. 323–407. Academic Press, New York.

    Google Scholar 

  • Schwan, H. P. andMaczuk, J. G. (1965) Electrode polarization impedance: limits of linearity.Proc. 18th ACEMB, p.24, Philadelphia.

  • Schwan, H. P. andFerris, C. D. (1968) Four-electrode null techniques for impedance measurement with high resolution.Rev. Sci. Instrum. 39, 481–485.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ferris, C.D., Rose, D.R. An operational amplifier 4-electrode impedance bridge for electrolyte measurements. Med. & biol. Engng. 10, 647–654 (1972). https://doi.org/10.1007/BF02476082

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02476082

Keywords