Skip to main content
Log in

Electromagnetic Interference with Electronic Medical Equipment Induced by Automatic Conveyance Systems

  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

Electromagnetic interference (EMI) with electronic medical equipment induced by automatic conveyance systems is estimated. We measured the electric intensities of electromagnetic waves transmitted by three self-controlled electric truck systems. We also observed EMI with an infusion pump and a syringe pump set 1 m from the rail. The maximum electric field intensity was observed at the supplied current frequency in two systems with non-contact power supply mechanisms. The highest value, 137.0 dBμV/m, was measured just beside the rail. This is higher than the international electromagnetic immunity standard limit for electronic medical equipment. EMI may occur if electronic medical equipment is used within 2 m of the rail when the system contains an inductive power supply mechanism. With a contact power supply mechanism, the electric field intensity was much lower than that of the immunity standard. EMI should not occur even when electronic medical equipment is used just beside the rail.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. Somani, S., and Woller, T. Automating the drug distribution system. Top. Hosp. Pharm. Manage. 9(1):19–34, 1989.

    Google Scholar 

  2. Nakao, A., Kawaguchi, H., and Tajimi, M. Outline of material distribution system in Osaka City Hospital. J. Hosp. Eng. Assoc. of Jpn. 36(2):193–8, 1994.

    Google Scholar 

  3. Hanaoka, Y. Trend of material distribution and its system (in Japanese). Monthly Shin Iryo 247:120–4, 1995.

    Google Scholar 

  4. Anonymous. Radiofrequency interference with medical devices. IEEE Eng. Med. Biol. Magazine 17(3):111–4, 1998.

  5. Dwyer, D. Medical device, adverse events, and electromagnetic interference. Int. J. Trauma Nurs. 5(1):19–21, 1999.

    Google Scholar 

  6. Electromagnetic Compatibility Conference (Japan), Research Report of the Usage of Radio-communication Equipment such as Cellular Telephone Handsets. Association of Radio Industries and Business (Japan), 1997.

  7. International Electrotechnical Commission International Standard IEC 60601-1-2. Medical Electrical Equipment, Part 1: General Requirements for Safety. 2: Collateral Standard: Electromagnetic Compatibility Requirements and Tests. Geneva, Switzerland: International Electrotechnical Commission, 1993.

    Google Scholar 

  8. International Electrotechnical Commission IEC 61000-4-3. Electromagnetic Compatibility (EMC), Part 4-3: Testing and measuring techniques. Radiated, radio-frequency, electromagnetic field immunity test. Geneva, Switzerland: International Electrotechnical Commission, 1998.

    Google Scholar 

  9. Hanada, E., Watanabe, Y., Antoku, Y., Kenjo, Y., Nutahara, H., and Nose, Y. Hospital construction materials: Poor shielding capacity with respect to signals transmitted by mobile telephones. Biomed. Instrum. Tech. 32:489–96, 1998.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hanada, E., Watanabe, Y. & Nose, Y. Electromagnetic Interference with Electronic Medical Equipment Induced by Automatic Conveyance Systems. Journal of Medical Systems 24, 11–20 (2000). https://doi.org/10.1023/A:1005424910489

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1005424910489

Navigation