Abstract
Measurement of solids hold-up in gas-liquid-solid systems was achieved by using a cylinder with a valve in each extremity, which allowed direct sampling inside the reactor causing minimal disturbances to the fluid flow. The method was developed and tested in a 60 L concentric draught tube airlift reactor. Validation of the method was done by means of an overall balance to the solid phase in the bioreactor.
Similar content being viewed by others
References
Kawase, Y. and Hashimoto, N. (1996). J. Chem. Tech. Biotechnol. 65, 325–334.
Kennard, M. and Janekeh, M. (1991). Biotechnol. Bioeng. 38, 1261–1270.
Livingston, A.G. and Zhang, S.F. (1993). Chem. Eng. Science, 48, 1641–1654.
Lu, W.-J., Hwang, S.-J. and Chang, C.-M. (1995). Chem. Eng. Science, 50, 1301–1310.
Siegel, M.H., Hallaile, M., Herskowitz, M. and Merchuk, J.C. (1988). In: King, R. (Ed.), 2nd International Conference on Bioreactor Fluid Dynamics, 21–23 September, 337–353.
Smith, B.S. and Skidmore, D.R. (1990). Biotechnol. Bioeng. 35, 483–491.
Verlaan, P. and Tramper, J. (1987). In: International Conference on Bioreactors and Biotransformations, 9–12 November, Gleneagles, Scotland, 363–373.
Vicente, A.A. and Teixeira, J.A. (1995). Bioprocess Eng. 14, 17–22.
Wenge, F., Chisti, Y. and Moo-Young, M. (1995). Ind. Eng. Chem. Res. 34, 928–935.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Freitas, C., Vicente, A.A., Mota, M. et al. A new sampling device for measuring solids hold-up in a three-phase system. Biotechnology Techniques 11, 489–492 (1997). https://doi.org/10.1023/A:1018405931310