Skip to main content
Log in

Royal academy of medicine in Ireland section of bioengineering

Proceedings of meeting held in dundalk, co. louth, in february 1998.

  • Published:
Irish Journal of Medical Science Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Doherty, M. J., Schlag, G., Schwarz, N., Molian, R. Nolan, P. Wilson, D. J. Biocompatibility of xenogenic bone, commercially available coral, a bioceramic and tissue sealant for human osteoblasts. Biomaterials 1994: 15, 601–608

    Article  PubMed  CAS  Google Scholar 

  2. Zambonin, G., Grano, M. Biomaterials in orthopaedic surgery: effects of different hydroxyapatites and demineralised bone matrix on proliferation rate and bone matrix synthesis by human osteoblasts. Biomaterials 1995: 16, 397402.

    Article  Google Scholar 

References

  1. McAvoy, G. J. The Development of a Vibro-acoustic Model of the Human Ear. M.Sc. Thesis, University of Dublin, 1995.

  2. Stasche, N., Foth, H. J., Hormann, K., Baker, A., Huthoff, C. Middle ear transmission disorders: tympanic membrane vibration analysis by laser doppler vibrometry. Acta Otolaryngol (Stockh) 1994; 114: 59–63.

    Article  CAS  Google Scholar 

References

  1. Odgaard, A. Three-dimensional methods for quantification of cancellous bone architecture. Bone 1997; 20: 315–328.

    Article  PubMed  CAS  Google Scholar 

  2. Kabel, J., vanRietbergen, B. Dalstra, M., Odgaard, A., Huiskes, R. The elastic properties of trabecular bone can be accurately predicted by fabric and volume fraction. Trans. Euro. Orthop. Res. Soc. 1997: 7: 3.

    Google Scholar 

References

  1. Cho, Y. I., Kensey, K. R. Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part I- Steady flows, Biorheology 1991; 28: 241–262.

    PubMed  CAS  Google Scholar 

  2. Lei, M. Computational Fluid Dynamics Analyses and Optimal Design of Bifurcating Blood Vessels. 1995.

Reference

  1. Bray, D., Reilly, R. S., Haskin, L., McCormack, B. A. O. Assessing motility through abdominal sound monitoring, In Proc. 19th IEEE/ Engineering in Medicine and Biology, Chicago, 1997; p. 54.

References

  1. Tancred, D. C. A New Bone Replacement Material. Ph.D. Thesis, National University of Ireland, University College Dublin, 1996.

  2. O’Kelly, K., Tancred, D., McCormack, S., Carr, A. A quantitative technique for comparing synthetic porous hydroxyapatite structures and cancellous bone. J. Mater. Sci.: Mater. Med. 1996; 7: 207–213.

    Article  CAS  Google Scholar 

References

  1. Bergmann, G., Graichen, F., Rohlmann, A. Hip joint loading during walking and running, measured in two patients. J. Biomech. 1993; 26: 969–990.

    Article  PubMed  CAS  Google Scholar 

  2. McCormack, B. A. O., Prendergast, P. J., O’Dwyer, B. Fatigue of hip replacements under torsional loads. Fatigue Fract. Eng. Mater. Strut, (in press).

References

  1. Dunne, N., Orr, J. Examination of the adhesive characteristics of curing PMMA bone cement. Innovation et Technologie en Biologie et Medecine, 1995; 16: 5: 638–647.

    Google Scholar 

  2. Dunne, N. Evaluation of Static and Dynamic Properties of PMMA Bone Cements and their Effects on Implant Fixation. PhD Thesis. The Queen’s University of Belfast, 1996.

References

  1. Kates, J. M. A time-domain digital cochlear model. IEEE Trans. Sig. Proc. 1991; 39: 2573–2592.

    Article  Google Scholar 

  2. Launer, S., Hohmann, V., Kollmeier, B. Loudness growth and loudness summation in hearing-impaired listeners. Graduiertenkolleg “Psychoakustik” and AG Medizinische Physik. 1995.

References

  1. Perktold, K., Resch, M. Numerical Flow Studies in Human Carotid Artery Bifurcations: Basic Discussion of the Geometric Factor in Atherogenesis. J. Biomed. Eng. 1990; 12: 111–123.

    Article  PubMed  CAS  Google Scholar 

  2. Ku, D. N., Giddens, D. P., Zarins, C. K., Glagov, S. Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress. Arteriosclerosis. 1985; 5: 293–302.

    PubMed  CAS  Google Scholar 

References

  1. Wiebe, de Vries, Veltink, P. H., Mattijs, Koper, P., Koopman Bart, F. J. M. Calculation of segment and joint angles of the lower extremities during gait using accelerometers, dynamic analysis using body fixed sensors: In Second World Congress of Biomechanics, Amsterdam, July 1994, p. 43-50.

  2. Hourigan, T. F., Lyons, G. M. A Preliminary study of the application of integrated accelerometers in gait correction. In Proc. 5th Institute of Physics & Eng. in Medicine, Clinical FES Meeting, Salisbury, England, 13-14 March 1997.

References

  1. Steenbeckers, L. P. A. Ergonomics Gegevens voor Kinderveiligheld: Technische Universiteit Delft: Faculteit van het Industrieel Ontwerpen Vakgroep Produktergonomie: Januari 1989.

  2. Snyder, R. G., Schneider, L. W., Owings, L., Reynolds, H. M., Golomb, D. H., Schork, M. A. Anthropometry of Infants, Children and Youths to Age 18 for Product Safety and Design consumer Product Safety Commission, Bethseda, MD: U.S. Department of Commerce. 1977: PB-270 227.

References

  1. Blum, G. W., Walker, P. S., Joshi, A., Hardinge, K. The dominance of cyclic sliding in producing wear in total knee replacement. Clin. Orthop. & Rel. Res. 1991; 273: 235–260.

    Google Scholar 

Reference

  1. Edwards, A. G., McNally, D. S., Mulholland, R. C, Goodship, A. E. The effects of posterior fixation on internal intervertebral disc mechanics. J. Bone Jt. Surg. [Br] 1997; 79B: 154–160.

    Article  Google Scholar 

Reference

  1. Ruan, J. S., Khalil, T., King, A. I. Dynamic head response of the head to impact by three dimensional finite element analysis. ASME J. Biomech. Eng. 1994; 116: 44–50.

    Article  CAS  Google Scholar 

References

  1. Weinberg, S., Lapointe, H. Cervical extension-flexion injury and internal derangement of the TMJ. J. Oral Maxillofacial Surg. 1987; 45: 653–656.

    Article  CAS  Google Scholar 

  2. Lyons, G., Brady, L., Simms An investigation of damage to the human temporomandibular joint during cranial accelerations. In 41st Annual Proceedings of the Association for the Advancement of Automotive Medicine. 1997; 315-330.

Reference

  1. Boskey, A. L. Hydroxyapatite formation in a dynamic collagen gel system: effects of type I collagen, lipids, and proteoglycans. J. Phys. Chem. 1989; 93: 1628–1633.

    Article  CAS  Google Scholar 

References

  1. Vaidhyanathan, B., Rao, K. J. Rapid microwave synthesis of hydroxyapatite. Bull. Mat. Sci. 1996; 19, (6): 1163–1165.

    Article  CAS  Google Scholar 

  2. Akao, M., Aoki, H., Kato, J. Mechanical properties of sintered hydroxyapatite for prosthetic applications. J. Mat. Sci. 1981; 16: 809–812.

    Article  CAS  Google Scholar 

References

  1. Williams, D. Diamond-like carbon and other thin films. Medical Device Tech. 1993: 8–13.

  2. O’Leary, ?., Dowling, D. P., Donnelly, K., O’Brien, T. P., Kelly, T. C., Weill, N., Elroy, R. Diamond like carbon coating for biomedical application. Key Engineering Materials 99–100, pp. 301-308, Trans Tech Publications: Switzerland 1005.

Reference

  1. Waide, D. V. Topography-Contact Area Relationships in the Elbow Joint. Ph.D. Thesis, National University of Ireland, University College Dublin, 1997.

Reference

  1. Wlaheim, G., Olerud, S., Ribbe, T. Mobility of the pubis symphysis; Measurement by an electromechanical method, Acta. Orthop. Scand. 1984; 55: 203–208.

    Google Scholar 

References

  1. Jensen, R. K. Body segment mass, radius and radius of gyration proportions of children. J. Biomech. 1986; 19: 359–368.

    Article  PubMed  CAS  Google Scholar 

  2. Dempster, W. T. Space Requirements of the Seated Operator. WADC-TR-55-159, Wright Patterson Air Force Base, 1955.

References

  1. Liberson, W. T., Holmquest, H. J., Scott, D., Dow, M. Functional electrotherapy in stimulation of the peroneal nerve synchronised with the swing phase of the gait in hemiplegic patients. Arch. Phys. Med. Rehab. 1961; 42: 101–105.

    CAS  Google Scholar 

  2. Willemson, A. T. M., Bloemhof, F., Boom, H. B. K. Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation, IEEE Trans. Biomed. Engl. 1990; 42: 1201–08.

    Article  Google Scholar 

Reference

  1. Bahill, A. T., Iandolo, J. M., Troost, Smooth pursuit eye movements in response to unpredictable target waveforms. Vision Res. 1980; 20: 923–931.

    Article  PubMed  CAS  Google Scholar 

References

  1. Finley, W. W., Etherton, M. D., Dickman, D., Karimian, D., Simpson, R. W. A simple EMG - reward system for biofeedback, training of children. Biofeedback and Self-Regulation. 1981; 6: 169–180.

    Article  PubMed  CAS  Google Scholar 

  2. Mackey, S. The use of computer-assisted feedback in a motor control task for cerebral palsied children. Physiotherapy. 1989; 75: 143–148.

    Article  Google Scholar 

Reference

  1. Kanchanavista, W., Pearson, G., Anstice, H. Influence of humidity on dimensional stability of a range of ion-leachable cements. Biomaterials 1995; 16: 921–929.

    Article  Google Scholar 

References

  1. Sullivan, D., Levy, I. M., Sheskier, S., Torzilli, P. A., Warren, R. F. Medial restraints to anterior-posterior motion of the knee. J. Bone Joint Surg. 1984; 66A: 930–36.

    Google Scholar 

  2. Fukubayashi, T., Torzilli, P. A., Sherman, M. F., Warren, R. F. An in-vitro biomechanical evaluation of anterior-posterior motion of the knee. J. Bone Joint Surg. 1982; 64A: 258–64.

    Google Scholar 

References

  1. Prendergast, P. J. Finite element analysis in tissue mechanics and orthopaedic implant design. Clin. Biomech. 12: 343–366.

  2. Ahmed, A. M. Nair, R., Burke, D. L., Miller, J. Transient and residual stresses and displacements in self-curing bone cement - Part II: thermoelastic analysis of the stem fixation system. J. Biomech. Eng. 1982; 104: 28–37.

    PubMed  CAS  Google Scholar 

References

  1. Delp, S. L., Loan, J. P., Moy, M. G., Zajae, F E., Topp, E. L., Rosen, J. M. An interactive graphics based model of the lower extremity to study orthopeadic procedures. IEEE. Trans. Biomed. Eng. 1990; 37: 757–767.

    Article  PubMed  CAS  Google Scholar 

References

  1. Cormack, W. A. The PROMAM (Prompting for Mammography) Project, Royal Observatory, Edinburgh, 27 October 1997: 12 pp.

  2. Starck, J. L., Murtagh, F., Bijaoui, H. Image and Data Analysis. The Multiscale Approach, Cambridge University Press, 1998, forthcoming.

Reference

  1. Merletti, R., Andina, A., Galante, M., Furlan, I. Clinical experience of electronic peroneal stimulators in 50 hemiparetic patients. Scand. J. Rehab. Med. 1979; 11: 111–121.

    CAS  Google Scholar 

References

  1. Lacroix, D., Prendergast, P. J., Murray, R., McAlinden, S., D’Arcy, E. The use of Quantitative Computed Tomography to generate a finite element model of the scapula bone. In Proceedings of the 14th Irish Manufacturing Committee, Eds.: Monaghan & Lyons 1997; 257-262.

  2. Van der Helm, F. C. T. The Shoulder Mechanism, A Dynamic Approach. PhD thesis, Delft University of Technology, 1991.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

McAlinden, M.G., Magowan, J., Wilson, D.J. et al. Royal academy of medicine in Ireland section of bioengineering. Ir. J. Med. Sc. 167, 256–276 (1998). https://doi.org/10.1007/BF02937426

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02937426

Keywords

Navigation