GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Gas chromatography-mass spectrometry ; Electron-capture negative ionization ; Toxaphene ; Seal blubber samples ; Antarctic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatography and electron-capture, negative-ionization, mass spectrometry (GC-ECNI-MS) in combination with a non-polar stationary phase (CP-Sil 2) was applied to study the composition of residues of the multicomponent toxaphene mixture in seal blubber from the Antarctic. In samples of the five Antarctic seal species eleven compounds of technical toxaphene (CTTs) were detected and six of them quantified by application of single standard compounds. Five abundant CTTs in seal blubber were included in the “Parlar 22 components standard” (commercially available) and one further was isolated and quantified for the first time. Finally, high levels of toxaphene were determined in Weddell seals and crabeaters confirming that toxaphene is a major organochlorine pollutant in the Antarctic.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Chiral stationary phases ; Enantioseparation ; Toxaphene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of the enantiomers of the compounds of technical toxaphene (CTTs) on heptakis(6-O-tert-butyldimethylsilyl-2,3-di-O-methyl)-β-cyclodextrin (β-TBDM) has been studied by gas chromatography with electron-capture detection (GC-ECD). Enantiomers of eight of the nine CTTs under investigation were separated on this chiral stationary phase. Separations of the enantioners of CTTs have hitherto been achieved ontert-butyldimethylsilylated β-cyclodextrin (β-BSCD). The chiral resolution values and separation factors of the CTTs on β-TBDM have been compared with those obtained on β-BSCD. Although several components coeluted, enantioselective determination of three CTTs was possible in an extract of seal blubber. For each CTT the first-eluting enantiomer was enantioenriched. Enantioselective accumulation of2-endo, 3-exo,5-endo,6-exo,-8,8,9,10-octachlorobornane (B8-1412) in biota has been established for the first time.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...