    ISSN: 1433-0458
    Keywords: Schlüsselwörter Piezoelektrischer Wandler ; Implantierbares Hörgerät ; Implantierbares Mikrofon ; Implantierbarer Wandler ; Innenohrschwerhörigkeit ; Schwerhörigkeit ; CAI ; TICA ; Key words Piezoelectric transducer ; Implantable hearing aid ; Implantable microphone ; Implantable transducer ; Sensori-neural hearing loss ; Cochlea amplifier implant ; TICA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary A microphone constructed for implantation in the posterior wall of the auditory canal and a piezoelectric transducer serving as the main components of an implantable hearing aid were temporally implanted in five patients during middle ear surgery under local anesthesia. The microphone was positioned beneath the skin of the auditory canal such that it completely covered the microphone membrane. The vibratory element of the transducer was coupled to the malleus in four patients with normal ossicular chains and directly to the stapes in one patient with missing incus. The microphone and transducer were electrically connected with an external battery-driven signal amplifier. Speech material and music were presented in the operation room at a sound level of 65 dB SPL under free-field conditions. The patients had to estimate the quality of speech, music, and their own voice as well as the effects of bone-conducting noises. All patients were able to hear with the system. An intraoperative talk without vision contact was possible without any problems, as was understanding of numerals („Freiburger Zahlentest”). Perception of music was judged as „clear and undistorted with all broadband component.” The estimation was also valid for one patient with a sensorineural hearing loss. One patient declared the music to be „a little of unnatural.” Bone-conducted sound was estimated as normal in two patients, better than without an implant in one patient with sensorineural hearing loss, and „somewhat metallic” in another patient. Hearing the own voice was considered „normal” in two cases „monotonous” in one case, and „a little bit roaring” in another case. An amplification factor that can be technically realized in an implantable hearing aid was necessary for one of the patients with sensorineural hearing loss to perceive music at a pleasant volume. On the basis of this study, essential requirements for the construction of a fully implantable hearing aid are fulfilled.
    Notes: Zusammenfassung Ein zur Implantation in die hintere Gehörgangswand vorgesehenes Mikrofon und ein piezoelektrischer Wandler als Hauptkomponenten eines implantierbaren Hörgeräts wurden bei fünf Patienten während Mittelohroperationen in Lokalanästhesie akut implantiert. Das Mikrofon wurde unter die Gehörgangshaut so positioniert, daß die Haut flach und bündig die Mikrofonmembran bedeckte. Bei vier Patienten mit intakter Ossikelkette wurde das schwingungsübertragende Wandlerelement an den Hammer angekoppelt, bei einem Patient mit Kettenunterbrechung direkt an den Steigbügel. Mikrofon und Wandler waren mit einem externen, batteriebetriebenen Signalverstärker verbunden. Im Operationssaal wurden genormtes Sprachmaterial und Musik unter Freifeldbedingungen bei einem Schallpegel von 65 dB SPL dargeboten. Die Patienten beurteilten die Übertragungsqualität von Sprache, Musik, der eigenen Stimme sowie von mechanischen Reibgeräuschen am Kopf. Alle Patienten konnten mit dem System hören. Ein intraoperatives Gespräch ohne Sichtkontakt war problemlos möglich, ebenso wurden Freiburger Zahlworte durchwegs richtig wiedergegeben. Die Musikdarbietung wurde als „reiner Klang”, „klar” und mit „ausgeprägten Höhen und Bässen” bezeichnet. Dies galt auch für einen Patienten mit deutlicher Innenohrschwerhörigkeit. Ein Patient gab die Musik als „etwas unnatürlich klingend” an. Körperschall wurde in 2 Fällen als normal, bei einem Patient mit Innenohrkomponente als besser als ohne Implantat empfunden sowie in einem Fall als „metallisch” klingend angegeben. Die Empfindung der eigenen Stimme wurde von 3 Patienten in einem Fall als normal, beim 2. als „monoton” und vom 3. Patienten als „leicht dröhnend” beschrieben. Bei dem Patient mit deutlicher Innenohrbeteiligung war für eine angenehme Lautstärke bei Musik ein Verstärkungsfaktor notwendig, der bei einem implantierbaren Hörgerät technisch möglich ist. Damit sind die wesentlichen Voraussetzungen geschaffen, mit den beiden getesteten Komponenten Mikrofon und Wandler ein vollständig implantierbares Hörgerät zu realisieren.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Cochlea-Amplifier-Implantat ; Elektromechanischer Wandler ; Gehörknöchelchenkette ; Hörverbesserung ; Implantierbares Hörgerät ; Implantierbares Mikrofon ; Implantierbare ; wiederaufladbare Batterie ; Innenohrschwerhörigkeit ; Innenohrstimulator ; Mastoid ; Medizinprodukt ; Mittelohr ; Ohr ; Ossikel ; piezoelektrischer Wandler ; Schallempfindungsschwerhörigkeit ; TICA ; Transkutane Energieübertragung ; Tübinger Implantat ; Key words Cochlea-amplifier implant ; Ear ; Electromechanical transducer ; Hearing aid ; Hearing improvement ; Hearing loss ; Implant ; Implantable hearing aid ; Implantable microphone ; Implantable rechargeable battery ; Inner ear stimulator ; Mastoid ; Medical device ; Middle ear ; Ossicles ; Ossicular chain ; Piezoelectric transducer ; Sensorineural hearing loss ; TICA ; Transcutaneous energy transmission ; Tuebingen implant
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary A fully implantable hearing aid consists of a sound receptor (microphone), an electronic amplifier including active audio-signal processing, an electromechanical transducer (actuator) for stimulating the ear by vibration, and an energy source. The energy source may be either a primary cell or a rechargeable (secondary) cell. As the energy requirements of an implantable hearing aid are dependent on the operating principle of the actuator, the operating principles of electromagnetic and piezoelectric transducers were examined with respect to their relative power consumption. The analysis showed that the energy requirements of an implantable hearing aid are significantly increased when an electromagnetic transducer is used. The power consumption of a piezoelectric transducer was found to be less than that of the electronic components alone. The energy needed to run a fully implantable hearing aid under these conditions would be 38 mWH per day. Primary cells cannot provide the energy needed for a minimum operation time of 5 years (70 WH), and therefore rechargeable cells must be used. A theoretical appraisal was carried out on nickel-cadmium, nickel-metal hydride, and lithium-ion cells to determine their suitability as well as to assess the risks associated with their use in an implant. Safety measures were drawn up from the results. Ni-MH cells were found to be the most suitable for use as an energy source for implantable hearing-aids because they are more robust than Li ion cells and their storage capacity is double that of Ni-Cd cells of similar size.
    Notes: Zusammenfassung Ein vollständig implantierbares Hörgerät besteht aus einem Schallempfänger (Mikrophon), einer Verstärkungselektronik mit Filtern und Regelbausteinen, einem elektromechanischen Wandler (Aktor) zur vibratorischen Anregung des Gehörs und einem Energiespeicher. Dieser Energiespeicher kann aus einer Primärbatterie oder aus einer wiederaufladbaren (Sekundär) Batterie bestehen. Der Energiebedarf des implantierbaren Hörgeräts ist davon abhängig, mit welchem Wandlerprinzip der Aktor arbeitet. Hier werden das elektromagnetische und das piezoelektrische Wandlerprinzip hinsichtlich ihrer Leistungsaufnahme betrachtet. Dabei zeigt sich, daß ein elektromagnetischer Wandler den Energiebedarf des implantierbaren Hörgeräts beträchtlich erhöht, während bei geeigneter Auslegung eines piezoelektrischen Wandlers die Leistungsaufnahme des Wandlers so gering gestaltet werden kann, daß sie gegenüber der Leistungsaufnahme der elektronischen Komponenten eine untergeordnete Rolle spielt. Bei optimierter Auslegung beträgt die für den Betrieb eines vollständig implantierbaren Hörgeräts benötigte Energie 38 mWh/Tag. Die für eine Lebensdauer von mindestens 5 Jahren benötigte Energiemenge von 70 Wh ist in Primärbatterien nicht mehr speicherbar, so daß wiederaufladbare Batterien eingesetzt werden müssen. Es werden Nickel-Cadmium (Ni-Cd-)-Nickel-Methallhydrid (Ni-MH-)- und Lithiumion-(Li-Ion-)-Zellen auf ihre Eignung für die Anwendung theoretisch untersucht. Dabei wird eine Risikobetrachtung für den Einsatz dieser Zellen in einem Implantat vorgenommen und ein Katalog von daraus folgenden Sicherheitsmaßnahmen aufgestellt. Als Ergebnis zeigt sich, daß die NI-MH-Zelle wegen ihrer Robustheit verglichen mit Li-Ion-Zellen und der ca. doppelt so großen Kapazität wie eine gleich große Ni-Cd-Zelle ein geeignetes System für die energetische Versorgung eines implantierbaren Hörgeräts darstellt.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Implantierbares Hörgerät ; Schwerhörigkeit ; Gehörknöchelchen ; Tübinger Implantat ; Implantierbares Mikrophon ; Elektronisches Hörimplantat ; Koppelelemente ; TICA ; CAI ; Key words Implantable hearing aid ; Hearing loss ; Ossicular chain ; Tübingen implant ; Implantable microphone ; Ossicular connectors ; TICA ; CAI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Development and short-term implantation results of the Tübingen implantable hearing aid (TI=Tübingen implant) have been presented [12, 24, 25]. The TI is designed for patients with sensorineural hearing loss due to a malfunction of the cochlear amplifier. This can be identified by the presence of positive recruitment and the absence of TEOAE (transitory evoked otoacoustic emissions). The Tübingen implant functions in two ways: it allows electronic amplification of the auditory signal and electromechanical signal transduction into a micromechanical vibratory stimulus. There are two paths by which vibratory stimulus reaches the cochlea: (1) directly through a perforation in the stapes foot plate into the perilymph or (2) via the ossicular chain. Made of pure titanium, the casing of the helium-tight welded transducer includes the piezoelectric actuator. An implantable manipulator device is designed for transducer positioning and anchoring in the mastoid cavity [7, 9]. Usually, the transducer probe tip is directly coupled to the body of the incus. This functions without a special coupling device by utilization of an Erbium-YAG laser [8]. Special anatomical situations or the loss of incus and/or stapes suprastructure, however, requires coupling of the vibratory signal to other points of the ossicular chain or to the perilymph. A major problem, however, was an intraoperative, irreversible link between the titanium probe tip and coupling elements. To overcome this problem, the coupling elements were made of gold. A crimp technique was developed, allowing the surgeon to induce cold deformation of the gold. The cold deformation technique (crimp) results in an irreversible coupling between the titanium probe tip and the golden coupling element.
    Notes: Zusammenfassung Über Entwicklung und erste Akutimplantationen des aktiven Tübinger Hörimplantates bei Patienten mit Innenohrschwerhörigkeit wurde kürzlich berichtet [12, 24, 25]. Es ist für Innenohrschwerhörige mit Ausfall des cochleären Verstärkers in den äußeren Haarzellen des Innenohrs konzipiert, welches sich durch positives Recruitment und Ausfall der TEOAE (transitory evoked otoacoustic emissions) erkennen läßt. Das Implantat nimmt das Schallsignal mit seinem implantierbaren Mikrophon auf, verstärkt es und setzt es mit seinem piezoelektrischen Wandler in einen mikromechanischen Stimulus für die inneren Haarzellen um, welcher entweder direkt an die Perilymphe oder indirekt über die Gehörknöchelchen zum Innenohr übertragen wird. Das Wandlergehäuse ist aus Reintitan gefertigt (ASTM F67, Grade 2), heliumdicht verschweißt (MIL-STD-883D) und enthält ein schwingfähiges Piezoelement. Der Wandler wird mit einem speziell dafür entwickelten, implantierbaren Mikromanipulator räumlich fest in der Mastoidhöhle verankert [7, 9]. Der Mikromanipulator erlaubt nach seiner Verankerung auf dem Planum mastoideum mittels Titanknochenschrauben die Feinpositionierung der Koppelstange des Wandlers zum gewünschten Zielpunkt von Ossikelkette oder Vestibulum. Um den Stimulus zu übertragen, muß eine zuverlässige Ankopplung des Koppelstangenendes an Kette oder Perilymphe erreicht werden. Dazu dient die direkte Ankopplung der Koppelstange an den Amboßkörper, über die bereits berichtet wurde [8]. Dabei wird das Koppelstangenende in eine mit dem Ulmer Erbium-YAG-Laser nach Pfalz et al. erzeugte Vertiefung in den Amboßkörper eingeführt. Ist der Amboßkörper anatomisch schlecht erreichbar oder liegt ein Kettendefekt vor, dann ist – je nach Situation – eine Ankopplung an den langen Amboßfortsatz, den Stapeskopf oder durch eine Fußplattenperforation an die Perilymphe wünschenswert. Zur Ankopplung am langen Amboßfortsatz oder Steigbügelkopf muß das Koppelstangenende intraoperativ dauerhaft am Zielossikel fixiert werden. Für den langen Amboßfortsatz (Durchmesser ca. 0,8 mm) kommt ein einfaches Aufsetzen der Koppelstange (Durchmesser 0,5 mm) aufgrund der Abrutschgefahr nicht in Frage. Über die mechanische Langzeitstabilität einer möglichen Klebung mit Glasionomerzement bei permanenter vibratorischer Stimulation ist wenig bekannt [13]. In der vorliegenden Arbeit wurden für die Ankopplung an den langen Amboßfortsatz (bei intakter Kette), an das Stapesköpfchen (bei fehlendem Amboß) sowie an die Perilymphe (bei fehlendem Stapesüberbau) geeignete Koppelelemente aus vorhandenen passiven Mittelohrprothesen abgeleitet und im Felsenbein getestet. Im Tiermodell (Foxhound) und beim Menschen dient zum Befestigen am langen Amboßfortsatz eine anformbare Bandschlaufe ähnlich der Öse einer Stapesprothese. Die Ankopplung an den Stapeskopf erfolgt mit einem Goldglöckchen vergleichbar dem einer Bell-Prothese [18]. Die direkte Übertragung an die Perilymphe wird mit Hilfe einer modifizierten Piston-Prothese nach Plester durchgeführt, die durch eine Fußplattenperforation in das Vestibulum eintaucht. Die Koppelelemente werden aus Gold hergestellt und müssen intraoperativ irreversibel mit dem Titan der Wandlerkoppelstange verbunden werden. Technisch geschieht dies mittels speziellen Schweißverfahren, die der Otochirurg intraoperativ naturgemäß nicht verwenden kann. In der vorliegenden Arbeit wurde eine Crimptechnik entwickelt, mit deren Hilfe der Operateur im Mittelohr aufgrund der Kaltflußeigenschaften des Goldes eine Verankerung am Titan der Koppelstange erzeugen kann. Dadurch erreicht er einen irreversiblen Verbund zwischen dem Gold des Koppelelements und dem Titan des Wandlers.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    HNO 45 (1997), S. 816-827 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Hörverbesserung ; Implantierbares Hörgerät ; Implantierbares Mikrofon ; Innenohrschwerhörigkeit ; Mastoid ; Medizinprodukt ; Mittelohr ; Schwerhörigkeit ; TICA ; Key words Hearing aid ; Hearing improvement ; Hearing loss ; Implantable hearing aid ; Implantable microphone ; Mastoid ; Medical device ; Middle ear ; Sensorineural hearing loss ; TICA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Fully implantable hearing aids and cochlea implants of the future require an implantable microphone. A hermetically sealed implantable microphone based on the idea of a microphone implanted in the posterior wall of the auditory canal, as suggested by Ohno et al. in 1988, is presented. Through consistent technological and clinical design optimization, it was possible to achieve a membrane diameter of only 4.5 mm (as opposed to 8 mm in the Japanese system) and a significant volume reduction of nearly 50%. The microphone weights only 0.4 g. In spite of this miniaturization, the performance characteristics of the microphone equal those of the Japanese model or are superior. The sound-pressure transfer function shows a very small ripple and the bandwidth amounts to approximately 10 kHz. Because of its high tuning and high no-load resonance frequency, the microphone is mostly insensitive to post-operational changes to the loading mass on the microphone membrane initiated by the covering skin of the auditory canal. The sound-pressure transfer factor at 1000 Hz is approximately 1.5 mV/Pa. Using different manufacturing technologies, this value can be increased in the range of 6–8 dB with a corresponding reduction in bandwidth. Due to the small mass, the microphone is highly insensitive to environmental mechanical disturbances. The module is made of pure titanium and is hermetically sealed according to Mil-Std 883 D. Full metal encapsulation and additional internal electronic components protect the microphone well against environmental electromagnetic influences (EMC).
    Notes: Zusammenfassung Zukünftige vollständig implantierbare Hörgeräte und Kochleaimplantate (CI) benötigen ein implantierbares Mikrofon. Hier wird ein hermetisch dichtes, implantierbares Mikrofon vorgestellt, das auf dem von Ohno et al. [24] vorgeschlagenen Prinzip eines Mikrofons zur Implantation in der hinteren Gehörgangswand basiert. Durch eine konsequente technologische und klinische Designoptimierung konnte ein Membrandurchmesser von nur 4,5 mm gegenüber 8 mm des japanischen Systems und eine deutliche Volumenreduzierung um fast 50% erreicht werden. Das Mikrofon wiegt nur noch 0,4 g. Die Betriebseigenschaften sind trotz dieser Miniaturisierung mit denen des japanischen Mikrofons vergleichbar oder ihm überlegen. Die Übertragungsfunktion weist eine sehr geringe Welligkeit auf und die Bandbreite beträgt etwa 10 kHz. Das Mikrofon ist aufgrund der Hochabstimmung und der hohen Leerlaufresonanzfrequenz weitgehend unempfindlich gegenüber postoperativen Änderungen des Massebelags der Mikrofonmembran. Der Schalldruckübertragungsfaktor erreicht bei 1000 Hz etwa 1,5 mV/Pa; dieser Wert kann mittels unterschiedlicher Fertigungstechnologien bei gleichzeitiger Verringerung der Bandbreite um etwa 6–8 dB gesteigert werden. Durch die geringe Masse wird eine hohe Unempfindlichkeit gegenüber mechanischen Einwirkungen erreicht. Das Modul ist vollständig aus reinem Titan gefertigt und nach Mil-Std. 883 D hermetisch gasdicht. Aufgrund der vollständigen metallischen Kapselung und zusätzlicher interner elektronischer Bauelemente ist das Mikrofon weitgehend gegenüber elektromagnetischen Umwelteinflüssen (EMV) geschützt.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Ohr ; Schwerhörigkeit ; TICA ; Implantierbares Hörgerät ; Mechanischer Transducer ; Implantierbares Mikrofon ; Key words Ear ; Hearing loss ; TICA ; Implantable hearing aid ; Mechanical transducer ; Implantable microphone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Recently, an implantable hearing aid for rehabilitation of sensorineural hearing loss has been developed. One component of the device is the microphone for implantation into the posterior canal wall. The membrane of the microphone can be covered by skin, cartilage, or fascia, avoiding reduction in sound transmission at the same time. In the study presented here, the microphone was implanted into 50 cadaver specimens of human temporal bone. Localization of the microphone was determined by the anatomical situation of the facial nerve. The microphone and the piezoelectric transducer could be implanted in 78% of the temporal bones after total mastoidectomy. In the final version of the microphone, the size was 4.5 mm and total weight 400 mg.
    Notes: Zusammenfassung Implantierbare Hörgeräte für Innenohrschwerhörige benötigen einen implantierbaren Schallaufnehmer in oder hinter dem Trommelfell oder subkutan in der Gehörgangswand. Das Schwingungsverhalten des Trommelfells kann individuell und frequenzabhängig extrem unterschiedlich sein, während die Gehörgangshaut reproduzierbar schwingt. Deshalb wurde in einem Verbundprojekt ein vollständig implantierbares Mikrofon für die Implantation in die hintere knöcherne Gehörgangswand in einer Form realisiert, daß Haut, Knorpel oder Fascie auf der Mikrofonmembran zu keiner klinisch relevanten Schalldämpfung führen. In der vorliegenden Studie wurde an 50 Felsenbeinen der operationstechnisch zweckmäßigste Implantationsort für ein Mikrofon erarbeitet, der 1. ausreichend trommelfellnah ist, der 2. der Gehörgangshaut flach aufliegt und der 3. gleichzeitig die intramastoidale Implantation eines Wandlers erlaubt. Die Lokalisation wurde wesentlich durch den Verlauf des N. facialis bestimmt. Gleichzeitig wurden in einem iterativen Verfahren Form und Größe des Mikrofons schrittweise an die chirurgische Anatomie des Implantatsortes sowie an die Operationstechnik angepaßt. Es konnte eine Mikrofonform gefunden werden, die die Implantation des Mikrofons als Bestandteil eines implantierbaren Hörgeräts in einer funktionell und topographisch adäquaten Form bei gemeinsamer Implantation mit dem Wandler in 78% der Felsenbeine erlaubte. In dieser Endform hat das Mikrofon einen Durchmesser der schallaufnehmenden Membran von 4,5 mm sowie ein Gesamtgewicht von 0,4 g und ist zur Implantation bei den meisten Patienten geeignet.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...