    The Angle Orthodontist (EH Angle Education & Research Foundation) ; 2016
    In:  The Angle Orthodontist Vol. 86, No. 6 ( 2016-11-01), p. 883-890
    In: The Angle Orthodontist, The Angle Orthodontist (EH Angle Education & Research Foundation), Vol. 86, No. 6 ( 2016-11-01), p. 883-890
    Abstract: Objective: To evaluate whether overloading of teeth can be avoided by utilizing aligners with reduced thicknesses of 0.4 mm or 0.3 mm. Materials and Methods: The experimental setup included an acrylic maxillary jaw model with tooth 11 separated and fixed via a 3-D force-moment transducer to a hexapod for experimental movement. Aligners tested were fabricated on duplicate stone models using commercially available polyethylene terephthalate glycol (PET-G) foils with thicknesses between 0.5 and 0.75 mm, and novel 0.4-mm- and 0.3-mm-thick foils. With the test aligner seated, 11 was bodily displaced in a labiopalatal direction in the range of ±0.25 mm while all six force-and-moment components exerted on this tooth were registered. Results: With the thinnest commercially available 0.5-mm aligner, median forces of −7.89 N and 8.37 N were measured for the maximum 0.25-mm movement of 11 in a labial and palatal direction, respectively. In comparison, force values were 35% and 71% lower for the novel aligners with a thickness of 0.4 mm and 0.3 mm, respectively. Conclusions: Novel “leveling” aligners with reduced thickness may reduce overloading of individual teeth during aligner therapy. Due to form instability of 0.3-mm aligners, we suggest a novel sequence of 0.4–0.5–0.75 mm for aligner systems using several foil thicknesses for load graduation within single setup steps. This would combine low stiffness of the initial aligner and relatively constant load increases throughout the treatment.
    Type of Medium: Online Resource
    ISSN: 0003-3219 , 1945-7103
    RVK:
    Language: English
    Publisher: The Angle Orthodontist (EH Angle Education & Research Foundation)
    Publication Date: 2016
    detail.hit.zdb_id: 2026352-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...