    ISSN: 1439-6327
    Keywords: Key words: Exercise ; Heart failure ; Oxygen uptake ; Transient response
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The transient response of oxygen uptake (V˙O2) to submaximal exercise, known to be abnormal in patients with cardiovascular disorders, can be useful in assessing the functional status of the cardiocirculatory system, however, a method for evaluating it accurately has not yet been established. As an alternative approach to the conventional test at constant exercise intensity, we applied a random stimulus technique that has been shown to provide relatively noise immune responses of system being investigated. In 27 patients with heart failure and 24 age-matched control subjects, we imposed cycle exercise at 50 W intermittently according to a pseudo-random binary (exercise-rest) sequence, while measuring breath-by-breath V˙O2. After determining the transfer function relating exercise intensity (W˙) to V˙O2 and attenuating the high frequency ranges (〉6 exercise-rest cycles · min−1), we computed the high resolution band-limited (0–6 cycles · min−1) V˙O2 response (0–120 s) to a hypothetical step exercise. The V˙O2 response showed a longer time constant in the patients than in the control subjects [47 (SD 37) and 31 (SD 8) s, respectively, P 〈 0.05]. Furthermore, the amplitude of the V˙O2 response after the initial response was shown to be significantly smaller in the patients than in the control subjects [176 (SD 50) and 267 (SD 54) ml · min−1 at 120 s]. The average amplitude over 120 s correlated well with peak V˙O2 (r = 0.73) and ΔV˙O2/ΔW˙ (r = 0.70), both of which are well-established indexes of exercise tolerance. The data indicated that our band-limited V˙O2 step response using random exercise was more markedly attenuated and delayed in the patients with heart failure than in the normal controls and that it could be useful in quantifying the overall functional status of the cardiocirculatory system.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1615-2573
    Keywords: Negative feedback ; Transfer function ; Exercise
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In exercise training, precise control of exercise intensity would maximize the training efficacy while minimizing risks. To adjust work rate, heart rate (HR) has been used as a measure of exercise intensity. Thus, we developed a servo-controller of HR using a cycle ergometer. After estimating the transfer function from work rate to HR, we optimized feedback parameters for achieving a quick and stable HR response by means of a computer simulation. We then examined the performance of the servo-controller of HR in 55 healthy volunteers. We set the target HR at 60% and 75% of the age-predicted maximum HR. Times required for HR to reach 90% of the target HR were 136 ± 33 and 137 ± 22s in the respective protocols. Standard deviations of the steady-state difference between the target and measured HRs were 2.5 ± 0.6 and 3.8 ± 1.1 beats/min. We conclude that the developed servo-controller makes it possible to precisely regulate HR and, thereby, exercise intensity.