GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: European Heart Journal, Oxford University Press (OUP), Vol. 44, No. 36 ( 2023-09-21), p. 3469-3477
    Abstract: Transcatheter closure of patent foramen ovale (PFO) is the recommended stroke prevention treatment in patients ≤60 years with cryptogenic ischemic stroke and PFO. Atrial fibrillation or flutter (AF) is a known potential procedure-related complication, but long-term risk of developing AF remains unknown. This paper studied the long-term risk of developing AF following PFO closure. Methods and results A Danish nationwide cohort study was conducted. During 2008–2020, this study identified a PFO closure cohort, a PFO diagnosis cohort without PFO closure, and a general population comparison cohort matched 10:1 to the PFO closure cohort on age and sex. The outcome was first-time AF diagnosis. Risk of AF and multivariable-adjusted hazard ratio (HR) of the association between PFO closure or PFO diagnosis and AF were calculated. A total of 817 patients with PFO closure, 1224 with PFO diagnosis, and 8170 matched individuals were identified. The 5 year risk of AF was 7.8% [95% confidence interval (CI): 5.5–10] in the PFO closure cohort, 3.1% (95% CI: 2.0–4.2) in the PFO diagnosis cohort, and 1.2% (95% CI: 0.8–1.6) in the matched cohort. The HR of AF comparing PFO closure with PFO diagnosis was 2.3 (95% CI: 1.3–4.0) within the first 3 months and 0.7 (95% CI: 0.3–1.7) thereafter. The HR of AF comparing PFO closure with the matched cohort was 51 (95% CI: 21–125) within the first 3 months and 2.5 (95% CI: 1.2–5.0) thereafter. Conclusion Patent foramen ovale closure was not associated with any substantial increased long-term risk of developing AF beyond the well-known procedure-related short-term risk.
    Type of Medium: Online Resource
    ISSN: 0195-668X , 1522-9645
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2001908-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: European Heart Journal - Cardiovascular Imaging, Oxford University Press (OUP), Vol. 24, No. 2 ( 2023-01-23), p. 250-259
    Abstract: Cardiac computed tomography (CT) is increasingly utilized during follow-up after left atrial appendage closure (LAAC). Hypoattenuated thickening (HAT) is a common finding and might represent either benign device healing or device-related thrombosis (DRT). The appearance and characteristics of HAT associated with the Watchman FLX have not been previously described. Therefore, we sought to investigate cardiac CT findings during follow-up after Watchman FLX implantation with a focus on HAT and DRT. Methods and results Retrospective single-centre, observational study including all patients with successful Watchman FLX implantation and follow-up cardiac CT between March 2019 and September 2021 (n = 244). Blinded analysis of CT images was performed describing the localization, extent, and morphology of HAT and correlated to imaging and histology findings in a canine model. Relevant clinical and preclinical ethical approvals were obtained. Overall, HAT was present in 156 cases (64%) and could be classified as either subfabric hypoattenuation (n = 59), flat sessile HAT (n = 78), protruding sessile HAT (n = 16), or pedunculated HAT (n = 3). All cases of pedunculated HAT and five cases of protruding sessile HAT were considered as high-grade HAT (n = 7). Subfabric hypoattenuation and flat sessile HAT correlated with device healing and endothelialization in histological analysis of explanted devices. Conclusion Subfabric hypoattenuation and flat sessile HAT are frequent CT findings for Watchman FLX, likely representing benign device healing and endothelialization. Pedunculated HAT and protruding HAT are infrequent CT findings that might represent DRT.
    Type of Medium: Online Resource
    ISSN: 2047-2404 , 2047-2412
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2042482-6
    detail.hit.zdb_id: 2647943-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: European Heart Journal - Case Reports, Oxford University Press (OUP), Vol. 4, No. 2 ( 2020-06-01), p. 1-4
    Abstract: The left atrial appendage (LAA) is the main source of thromboembolism in atrial fibrillation (AF). Transcatheter closure is non-inferior to warfarin therapy in preventing stroke. Case summary  A patient with two consecutive strokes associated with AF was referred for transcatheter LAA occlusion (LAAO). Preprocedural cardiac CT and transoesophageal echocardiography demonstrated a spontaneously occluded LAA with a smooth left atrial surface, with stationary results at 6- and 12-month imaging follow-up. Warfarin was discontinued, and life-long aspirin instigated. Discussion  Left atrial appendage occlusion has shown non-inferiority to warfarin for prevention of stroke, cardiovascular death, and all-cause mortality. No benefits from anticoagulation have been demonstrated in patients with embolic stroke of undetermined source. In the present case, we observed that the LAA was occluded and, therefore, treated with aspirin monotherapy assuming similar efficacy as transcatheter LAAO.
    Type of Medium: Online Resource
    ISSN: 2514-2119
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2020
    detail.hit.zdb_id: 2948381-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: European Heart Journal - Case Reports, Oxford University Press (OUP), Vol. 7, No. 7 ( 2023-07-03)
    Abstract: Pulmonary embolism (PE) is common, and it is the third leading cause of cardiovascular death. The management of patients with high-risk PE generally consists of systemic thrombolysis; however, surgical or catheter-directed treatment (CDT) can be considered in selected cases. Case summary A 78-year-old female patient presenting with acute severe dyspnoea develops out-of-hospital cardiac arrest (OHCA). She was admitted with return of spontaneous circulation and a critical haemodynamic state upon arrival to the catheterization laboratory with an estimated no-flow time of 1 min and low-flow time of 52 min. An acute pulmonary angiogram reveals massive PE. After a PE response team conference, the patient was not found eligible for extracorporeal membrane oxygenation, surgery, or thrombolysis. The patient was treated with catheter-directed mechanical thrombectomy 129 min after first medical contact. The patient recovered and was discharged without any neurological deficits. Discussion Catheter-directed mechanical thrombectomy was a successful treatment in a patient with OHCA secondary to high-risk PE, where thrombolysis and surgical interventions were considered contraindicated. This case underlines the future perspectives of CDT and also that a multidisciplinary team approach may benefit patients with high-risk PE.
    Type of Medium: Online Resource
    ISSN: 2514-2119
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2948381-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: European Heart Journal - Case Reports, Oxford University Press (OUP)
    Abstract: Device-related thrombosis (DRT) is a known complication to left atrial appendage closure (LAAC). The surface of a LAAC device should ideally have antithrombotic properties. The novel WATCHMAN FLX Pro (WFP) incorporates a fluoropolymer coated fabric membrane designed to increase thromboresistance and facilitate endothelialisation. Such features could potentially allow for a minimal post-procedural antithrombotic regimen. Radiopaque platinum markers at the device shoulders and a large 40 mm device are other novel features of the WFP. Case Summary A 75-year old man with AF was referred for LAAC due to prior subdural haemorrhage during direct-acting anticoagulation treatment. He underwent the first-in-human WFP implantation as part of the WATCHMAN FLX Pro CT study (NCT05567172). Computed tomography (CT) was used for preplanning and the procedure was performed under local analgesia guided by intracardiac echocardiography (ICE) from the left atrium without any complications. Postprocedural antithrombotic treatment consisted of acetylsalicylic acid 75 mg/day only and 45-day CT, transoesophageal echocardiography (TEE) and magnetic resonance imaging (MRI) demonstrated optimal device position with complete LAA closure. Hypoattenuated thickening (HAT; 6mm) appeared on the device as a smooth surface in continuity with the left atrial wall on CT and TEE. A specific magnetic resonance T1-weighted scan, used for visualisation of fresh thrombus, suggested this to represent tissue ingrowth rather than thrombus. Discussion The advanced follow-up imaging protocol suggested a good WFP implantation result with signs of tissue ingrowth at 45days. The added radiopaque markers facilitated optimal deployment, evaluation of device stability during tug test and assessment of device protrusion into the LA.
    Type of Medium: Online Resource
    ISSN: 2514-2119
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2024
    detail.hit.zdb_id: 2948381-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: European Journal of Cardio-Thoracic Surgery, Oxford University Press (OUP), Vol. 52, No. 4 ( 2017-10-01), p. 704-709
    Type of Medium: Online Resource
    ISSN: 1010-7940 , 1873-734X
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2017
    detail.hit.zdb_id: 1500330-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...