    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 33, No. 5 ( 2023-05), p. 710-717
    Abstract: Mortality between stages 1 and 2 single-ventricle palliation is significant. Home-monitoring programmes are suggested to reduce mortality. Outcomes and risk factors for adverse outcomes for European programmes have not been published. Aims: To evaluate the performance of a home-monitoring programme at a medium-sized United Kingdom centre with regards survival and compare performance with other home-monitoring programmes in the literature. Methods: All fetal and postnatal diagnosis of a single ventricle were investigated with in-depth analysis of those undergoing stage 1 palliation and entered the home-monitoring programme between 2016 and 2020. The primary outcome was survival. Secondary outcomes included multiple parameters as potential predictors of death or adverse outcome. Results: Of 217 fetal single-ventricle diagnoses during the period 2016–2020, 50.2% progressed to live birth, 35.4% to stage 1 and 29.5% to stage 2. Seventy-four patients (including 10 with postnatal diagnosis) entered the home-monitoring programme with six deaths making home-monitoring programme mortality 8.1%. Risk factors for death were the hybrid procedure as the only primary procedure (OR 33.0, p 〈 0.01), impaired cardiac function (OR 10.3, p 〈 0.025), Asian ethnicity (OR 9.3, p 〈 0.025), lower mean birth-weight (2.69 kg versus 3.31 kg, p 〈 0.01), and lower mean weight centiles during interstage follow-up (mean centiles of 3.1 versus 10.8, p 〈 0.01) Conclusion: Survival in the home-monitoring programme is comparable with other home-monitoring programmes in the literature. Hybrid procedure, cardiac dysfunction, sub-optimal weight gain, and Asian ethnicity were significant risk factors for death. Home-monitoring programmes should continue to raise awareness of these factors and seek solutions to mitigate adverse events. Future work to generalise home-monitoring programme and single-ventricle fetus to stage 2 outcomes in the United Kingdom will require multi-centre collaboration.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2018
    In:  Cardiology in the Young Vol. 28, No. 12 ( 2018-12), p. 1431-1435
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 28, No. 12 ( 2018-12), p. 1431-1435
    Abstract: The objectives of this study were to describe the approach to stenting arterial shunts in adult congenital patients with single-ventricle physiology and to assess the medium-term clinical and haemodynamic outcomes following stent insertion. Background Adult patients with single-ventricle physiology and pulmonary blood flow dependent on a surgically placed arterial shunt who did not progress to venous palliation are extremely challenging to manage. Progressive cyanosis secondary to narrowing of the shunt has a marked impact on exercise tolerance and results in intolerable well-being for these patients. Stenting arterial shunts in adult patients is one method that can help improve pulmonary blood flow. There is very limited information in the literature about this patient. Methods This is a retrospective study for arterial shunts stenting conducted between 2008 and 2016. The peripheral oxygen saturations, the NYHA status, the haemoglobin, and the degree of atrio-ventricular valve regurgitation as assessed on transthoracic echo were compared before and 6–12 months after procedures. Results There was a short-term improvement in oxygen saturations; the pre-procedure mean was 75.8 (SD 2.55)% (range 70–85%) and post-procedure mean was 83 (SD 2.52)% (range 78–87%), with a p value of 0.04. Haemoglobin level decreased from a pre-procedure mean of 22.06–20.28 g/L 6 months post procedure (range 18.1–24.4 to 13–23.3 g/L), with a p value of 0.44. NYHA class decreased from a mean of 3.2–2.2 post procedure. Left atrial volume for four of the cases did not change (22.6–76.6 ml [mean 48.4 ml] to 29.6–72.9 ml [mean 52 ml] , p value: 0.83). Conclusions Stenting stenotic arterial shunts is a useful method to gain a medium-term improvement on the oxygen saturation and clinical symptoms, and may act as a useful intermediate step for further management plans.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2023
    In:  Journal of Clinical and Translational Science Vol. 7, No. 1 ( 2023)
    In: Journal of Clinical and Translational Science, Cambridge University Press (CUP), Vol. 7, No. 1 ( 2023)
    Abstract: Contactless photoplethysmography (PPG) potentially affords the ability to obtain vital signs in pediatric populations without disturbing the child. Most validity studies have been conducted in laboratory settings or with healthy adult volunteers. This review aims to evaluate the current literature on contactless vital signs monitoring in pediatric populations and within a clinical setting. Methods: OVID, Webofscience, Cochrane library, and clinicaltrials.org were systematically searched by two authors for research studies which used contactless PPG to assess vital signs in children and within a clinical setting. Results: Fifteen studies were included with a total of 170 individuals. Ten studies were included in a meta-analysis for neonatal heart rate (HR), which demonstrated a pooled mean bias of −0.25 (95% limits of agreement (LOA), −1.83 to 1.32). Four studies assessed respiratory rate (RR) in neonates, and meta-analysis demonstrated a pooled mean bias of 0.65 (95% LOA, −3.08 to 4.37). All studies were small, and there were variations in the methods used and risk of bias. Conclusion: Contactless PPG is a promising tool for vital signs monitoring in children and accurately measures neonatal HR and RR. Further research is needed to assess children of different age groups, the effects of skin type variation, and the addition of other vital signs.
    Type of Medium: Online Resource
    ISSN: 2059-8661
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2898186-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 1809
    In:  Archaeologia Vol. 2, No. 2 ( 1809), p. 364-366
    In: Archaeologia, Cambridge University Press (CUP), Vol. 2, No. 2 ( 1809), p. 364-366
    Abstract: Give me leave to add the following particulars (by way of additional note to what is said in the History and Antiquities of the Church of Ely, page 85,) concerning the removal of some Bones, in the pious conservation of which our ancestors were pleased to interest themselves, from a grateful remembrance of that beneficence which the persons there mentioned had exercised towards the Religious of this place. These bones had for a long time been immured within the north wall of the late choir. When it became necessary, on account of removing the choir to the east end of the church, to take down that wall, I thought proper to attend, and also gave notice of it to several gentlemen, who were desirous of being present when the wall was demolished. There were the traces of their several effigies on the wall, and over each of them an inscription of their names. Whether their relicks were still to be found was uncertain; but I apprised those who attended on that occasion, May 18, 1769, that, if my surmises were well founded, no head would be found in the cell which contained the bones of Brithnoth, duke of Northumberland. The ground of my expectation in that particular circumstance was the account given by the author of the Liber Eliensis of the unfortunate battle of Maldon in Essex, A. D. 991, that the Danes took away with them the head of that brave warrior. The event corresponded to my expectation.
    Type of Medium: Online Resource
    ISSN: 0261-3409 , 2051-3186
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 1809
    detail.hit.zdb_id: 2491219-0
    detail.hit.zdb_id: 2491226-8
    detail.hit.zdb_id: 211331-4
    SSG: 6,14
    SSG: 7,25
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2022
    In:  Cardiology in the Young Vol. 32, No. 1 ( 2022-01), p. 42-47
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 32, No. 1 ( 2022-01), p. 42-47
    Abstract: Infants with complex cyanotic CHD can become symptomatic from insufficient pulmonary blood supply following either ductal closure or due to outflow tract obstruction. Blalock–Taussig shunt mortality remains significant and recent studies have highlighted the advantages of using transcatheter alternatives. We present here our experience in changing our primary choice of palliation from the Blalock–Taussig shunt to transcatheter palliation with either a ductal stent or, if antegrade flow is present, a right ventricular outflow tract stent. This is a retrospective, single-unit cohort study. Eighty-seven infants underwent palliation for insufficient pulmonary blood flow at under 3 months of age between 2012 and 2019. On an intention-to-treat basis, 29 underwent insertion of a Blalock–Taussig shunt, 36 duct stents, and 22 right ventricular outflow tract stents at median ages of 15, 9, and 32 days, respectively, and median weights of 3.3, 3.1, and 3.1 kg, respectively. No primary Blalock–Taussig shunts have been performed in our institution since 2017. At 30-days there had been one death in each group (univariable p = 0.93) and deaths prior to repair totalled three in the shunt group, four in the ductal stent group, and two in the right ventricular outflow tract stent group (univariable p = 0.93). Reintervention on the pulmonary circuit prior to next stage of surgery was more frequent in those undergoing transcatheter intervention, reaching statistical significance by logrank (p = 0.012). In conclusion, within this work we provide further evidence of the safety and efficacy of transition from a primary surgical to primary transcatheter palliation pathway in infants with insufficient pulmonary blood supply.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2022
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 32, No. 9 ( 2022-09), p. 1407-1414
    Abstract: No established risk prediction tool exists in United Kingdom and Irish Paediatric Cardiology practice for patients undergoing cardiac catheterisation. The Catheterisation RISk score for Paediatrics is used primarily in North American practice to assess risk prior to cardiac catheterisation. Validating the utility and transferability of such a tool in practice provides the opportunity to employ an already established risk assessment tool in everyday practice. Aims: To ascertain whether the Catheterisation RISk score for Paediatrics assessment tool can accurately predict complications within United Kingdom and Irish congenital catheterisation practice. Methods: Clinical and procedural data including National Institute for Cardiovascular Outcomes Research derived outcome data from 1500 patients across five large congenital cardiology centres in the United Kingdom and Ireland were retrospectively collected. Catheterisation RISk score for Paediatrics were then calculated for each case and compared with the observed procedural outcomes. Chi-square analysis was used to determine the relationship between observed and predicted events. Results: Ninety-eight (6.6%) patients in this study experienced a significant complication as qualified by National Institute for Cardiovascular Outcomes Research classification. 4% experienced a moderate complication, 2.3% experienced a major complication and 0.3% experienced a catastrophic complication resulting in death. Calculated Catheterisation RISk score for Paediatrics scores correlated well with all observed adverse events for paediatric patients across all CRISP categories. The association was also transferable to adult congenital heart disease patients in lower Catheterisation RISk score for Paediatrics categories (CRISP 1–3). Conclusion: The Catheterisation RISk score for Paediatrics score accurately predicts significant complications in congenital catheterisation practice in the United Kingdom and Ireland. Our data validated the Catheterisation RISk score for Paediatrics assessment tool in five congenital centres using National Institute for Cardiovascular Outcomes Research-derived outcome data.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2022
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 33, No. 10 ( 2023-10), p. 1873-1878
    Abstract: To study the impact of out-of-hours delivery on outcome for neonates with antenatally diagnosed transposition of the great arteries. Setting Tertiary paediatric cardiology centre (Yorkshire, United Kingdom), with co-located tertiary neonatal unit. Patients Neonates with antenatally diagnosed simple transposition of the great arteries delivered out-of-hours (Monday to Friday 17:00–08:00 and weekends) versus in-hours between 2015 and 2020. Outcome The primary outcome was survival to hospital discharge. Secondary outcomes included neurological morbidity, length of stay, and time to balloon atrial septostomy. Results Of 51 neonates, 38 (75%) were delivered out-of-hours. All neonates born in the tertiary centre survived to discharge. Time to balloon atrial septostomy was slightly longer for out-of-hours deliveries compared to in-hours (median 130 versus 93 mins, p = 0.33). Neurological morbidity occurred for nine (24%) patients in the out-of-hours group and one (8%) in-hours (OR 3.72, 95% CI: 0.42–32.71, p = 0.24). Length of stay was also similar (18.5 versus 17.3 days, p = 0.59). Antenatal diagnosis of a restrictive atrial septum was associated with a lower initial pH (7.03 versus 7.13; CI: 0.03–0.17, p = 0.01), longer length of stay (22.6 versus 17.3 days; CI: 0.37–10.17, p = 0.04), and increased neurological morbidity (44% versus 14%; OR 4.80, CI 1.00–23.15, p = 0.05). A further three neonates were delivered in surrounding hospitals, with a mortality of 67% (versus 0 in tertiary centre; OR 172, CI 5-5371, p = 0.003). Conclusion Neonates with antenatally diagnosed transposition of the great arteries have similar outcomes when delivered out-of-hours versus in-hours. Antenatal diagnosis of restrictive atrial septum is a significant predictor of worse outcomes. In our region, delivery outside the tertiary cardiac centre had a significantly higher risk of mortality.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2011
    In:  Cardiology in the Young Vol. 21, No. 3 ( 2011-06), p. 271-280
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 21, No. 3 ( 2011-06), p. 271-280
    Abstract: To describe the difficulties and differing techniques in the transcatheter placement of amplatz ventricular septal defect devices to close perimembranous ventricular septal defects and place these in the context of the expanding literature on ventricular septal defect catheter closure. Background Surgery remains the established first-line therapy for closure of haemodynamically significant perimembranous ventricular septal defects. Transcatheter techniques appeared to promise a possible alternative, obviating the need for cardiac surgery. However, significant technical and anatomical constraints coupled with ongoing reports of a high incidence of heart block have prevented these hopes from being realised to any significant extent. It is likely that there are important methodological reasons for the high complication rates observed. The potential advantages of transcatheter perimembranous ventricular septal defect closure over surgery warrant further exploration of differing transcatheter techniques. Methods Between August, 2004 and November, 2009, 21 patients had a perimembranous ventricular septal defect closed with transcatheter techniques. Of these, 14 were closed with a muscular amplatz ventricular septal defect device. The median age and weight at device placement were 8 years, ranging from 2 to 19 years, and 18.6 kilograms, ranging from 10 to 21 kilograms, respectively. Results There were 25 procedures performed on 23 patients using 21 amplatz ventricular septal defect devices. Median defect size on angiography was 7.8 millimetres, ranging from 4 to 14.3 millimetres, with a median device size of 8 millimetres, ranging from 4 to 18 millimetres, and a defect/device ratio of 1.1, with a range from 0.85 to 1.33. Median procedure time was 100 minutes, with a range from 38 to 235 minutes. Adverse events included device embolisation following haemolysis in one, and new aortic incompetence in another, but there were no cases of heart block. Median follow-up was 41.7 months, with a rangefrom 2 to 71 months. Conclusions Evaluating transcatheter closure of perimembranous ventricular septal defect using amplatz ventricular septal defect devices remains important, if a technically feasible method with low and acceptable complication rates is to be identified. Incidence of heart block may be minimised by avoiding oversized devices, using muscular devices, and accepting defeat if an appropriately selected device pulls through. Given the current transcatheter technologies, the closure of perimembranous ventricular septal defects should generally be performed in children when they weigh at least 10 kilograms.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2011
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2012
    In:  Cardiology in the Young Vol. 22, No. 5 ( 2012-10), p. 610-614
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 22, No. 5 ( 2012-10), p. 610-614
    Abstract: To describe endovascular stent placement using partially covered stents to preserve flow in head and neck vessels. Background Endovascular stent placement has become established as a first-line therapy for native coarctation of the aorta or re-coarctation in older children and adults. Increasingly covered stents are becoming the preferred option over bare-metal stents because of the perceived lower risk of aneurysm formation. Open-cell bare-metal stents are chosen when there is a high likelihood of jailing a head and neck vessel. Here we describe partial uncovering of a covered stent before implantation to allow flow through the uncovered portion of the stent to the branch vessel but preserve the covering over the majority of the remaining stent. Methods We describe two cases with aortic arch hypoplasia and re-coarctation, both of which required two partially uncovered stents for a satisfactory result. Conclusions Endovascular stent placement is becoming the preferred option in the management of coarctation of the aorta in older children and adults. Strategies to deal with transverse arch hypoplasia and multiple levels of aortic arch obstruction frequently involving branch vessels or aneurysms need to be considered before these procedures are embarked upon. Partially uncovering stents may afford more protection than using bare-metal stents in the transverse and distal arch while preserving flow in head and neck branches, and is a technically straightforward procedure.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2012
    detail.hit.zdb_id: 2060876-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    Cambridge University Press (CUP) ; 2019
    In:  Cardiology in the Young Vol. 29, No. 12 ( 2019-12), p. 1432-1434
    In: Cardiology in the Young, Cambridge University Press (CUP), Vol. 29, No. 12 ( 2019-12), p. 1432-1434
    Abstract: The Fontan procedure is the final stage of surgical palliation for a single-ventricle circulation. Significant complications are common including rhythm disturbance necessitating implantation of a permanent pacemaker. This has been widely considered a negative prognostic indicator. Methods: This single-centre, retrospective case control study involved all patients who underwent the Fontan procedure at the Leeds Congenital Heart Unit between 1990 and 2015 and have had regular follow-up in Yorkshire and Humber, United Kingdom. 167 Fontan patients were identified of which 2 were excluded for having a pre-procedure pacemaker. Of the remainder, 23 patients required a pacemaker. Outcomes were survival, early and late complications, need for further intervention and oxygen saturation in long-term follow-up. Results: There was no difference in survival (30-day survival pacemaker 92.6%, sinus rhythm 90.5%, p = 0.66, 1-year pacemaker 11.1%, sinus rhythm 10.1%, p = 1). The pacemaker group was more likely to have cerebral or renal complications in the first-year post-procedure (acute kidney injury: sinus rhythm 0.8%, pacemaker 19.1%, p = 0.002). No difference was observed in longer term complications including protein losing enteropathy (sinus rhythm 3.5%, pacemaker 0% p = 1). There was no difference in saturations between the two groups at follow-up. Paced patients were more likely to have required further intervention, with a higher incidence of cardiopulmonary bypass procedures (sinus rhythm 6.3%, pacemaker 35%, p 〈 0.001). Conclusions: Despite an increase in early complications and the need for further interventions, pacemaker requirement does not appear to affect long-term survival following the Fontan procedure.
    Type of Medium: Online Resource
    ISSN: 1047-9511 , 1467-1107
    Language: English
    Publisher: Cambridge University Press (CUP)
    Publication Date: 2019
    detail.hit.zdb_id: 2060876-7