GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    In:  (Professorial dissertation), Christian-Albrechts-Universität zu Kiel, Kiel, Germany, 144, [18] pp
    Publication Date: 2021-02-10
    Type: Thesis , NonPeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    Institut für Meereskunde
    Publication Date: 2022-05-03
    Description: Die Sestonbestimmung hat den Vorteil, eine einfache, vielseitig anwendbare Methode in der biologischen Meereskunde zu sein. Ihre Genauigkeit hängt in erster Linie von der Beschaffenheit des Filtermaterials, der Größe der Filter und den Wägebedingungen ab. In diesem Zusammenhang werden drei Filtersorten miteinander verglichen: Papierfilter (Schleicher & Schüll 575), Sartorius-Membranfilter (SM 11304) und Glasfaserfilter (Whatman GF/C). Die Glasfaserfilter wurden hierbei, soweit bekannt, zum ersten Mal für die Sestonbestimmung benutzt. In der Filtrationsleistung sind sie den Membranfiltern vergleichbar. Aus voneinander unabhängigen Doppelbestimmungen wird die Standardabweichung der Methode bei der Verwendung der verschiedenen Filtersorten ermittelt. Die größte Genauigkeit erreichten Whatman-Glasfaserfilter (⌀ 2,5 cm) mit ± 0,15 mg auf der 95% Wahrscheinlichkeitsebene. Zum Schluß wird eine neue Filtationsapparatur beschrieben und eine ausführliche Arbeitsvorschrift gegeben. Seston determination has the advantage of being a simple method with a wide range of application in biological oceanography. Its accuracy depends mainly on the quality of the filter material, the size of the filters and the weighing conditions. Under these aspects three filter types are compared: paper filters (Schleicher& Schüll 575), Sartorius membrane filters (SM 11304) and glassfibre filters (Whatman GF/C). The glassfibre filters have been used here, as far as is known, for the first time for seston determination. Their filtration efficiency is comparable to that of the membrane filters. By means of independent double determinations the standard deviation of the method shown by the three filter types tested is calculated. The highest accuracy was attained by Whatman glassfibre filters (⌀ 2.5 cm) with ± 0.15 mg on the 95% probability level. Finally, a new filtration apparatus is described and detailed directions for determining seston given.
    Type: Article , NonPeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    Institut für Meereskunde
    Publication Date: 2022-05-02
    Type: Article , NonPeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2022-08-04
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...