GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (1)
Publikationsart
Verlag/Herausgeber
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 10 (1999), S. 0 
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Multisite Ventricular Pacing in Heart Failure. Introduction: We studied the effects on cardiac function of pacing two right and two left ventricular sites in normal and failing hearts with a normal QRS duration. Methods and Results: Hemodynamic parameters were studied in isoflurane-anesthetized dogs with normal hearts and dogs with heart failure induced by rapid ventricular pacing. Unipolar intramyocardial electrodes were placed at the high right atrium and the apex (A) and base (B) of the left (L) and right (R) ventricles (V). Data were collected after pacing for 5 to 20 minutes. In normal dogs, without bundle branch block (BBB), pacing at either the apex or the base of the left ventricle increased cardiac output by approximately 10% compared with right ventricular apex (RVA) pacing with an AV delay of 10 msec. Positive dP/dt increased approximately 10% during four-site left and right ventricular apex and base (LRVAB) pacing compared with RVA pacing. In dogs with heart failure but without BBB, cardiac output increased by 8.5% (P 〈 0.01) during four-site ventricular pacing with AV delays of 0 and 60 msec compared with RVA pacing. Positive dp/dt increased by 23.5% (P 〈 0.001) with an AV delay of 0 msec and 9.6% (P 〈 0.001) with an AV delay of 60 msec during LRVAB pacing compared with RVA pacing. His-bundle pacing was associated with increased cardiac output compared with RVA pacing. Conclusions: We conclude that pacing simultaneously at two right and two left ventricular sites significantly improves cardiac function compared with single RVA pacing, with or without sequential AV synchrony, in dogs with rapid ventricular pacing-induced heart failure and no BBB.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...