GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (2)
Publikationsart
Verlag/Herausgeber
Erscheinungszeitraum
Jahr
  • 1
    ISSN: 1439-6327
    Schlagwort(e): Key words: Exercise ; Heart failure ; Oxygen uptake ; Transient response
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The transient response of oxygen uptake (V˙O2) to submaximal exercise, known to be abnormal in patients with cardiovascular disorders, can be useful in assessing the functional status of the cardiocirculatory system, however, a method for evaluating it accurately has not yet been established. As an alternative approach to the conventional test at constant exercise intensity, we applied a random stimulus technique that has been shown to provide relatively noise immune responses of system being investigated. In 27 patients with heart failure and 24 age-matched control subjects, we imposed cycle exercise at 50 W intermittently according to a pseudo-random binary (exercise-rest) sequence, while measuring breath-by-breath V˙O2. After determining the transfer function relating exercise intensity (W˙) to V˙O2 and attenuating the high frequency ranges (〉6 exercise-rest cycles · min−1), we computed the high resolution band-limited (0–6 cycles · min−1) V˙O2 response (0–120 s) to a hypothetical step exercise. The V˙O2 response showed a longer time constant in the patients than in the control subjects [47 (SD 37) and 31 (SD 8) s, respectively, P 〈 0.05]. Furthermore, the amplitude of the V˙O2 response after the initial response was shown to be significantly smaller in the patients than in the control subjects [176 (SD 50) and 267 (SD 54) ml · min−1 at 120 s]. The average amplitude over 120 s correlated well with peak V˙O2 (r = 0.73) and ΔV˙O2/ΔW˙ (r = 0.70), both of which are well-established indexes of exercise tolerance. The data indicated that our band-limited V˙O2 step response using random exercise was more markedly attenuated and delayed in the patients with heart failure than in the normal controls and that it could be useful in quantifying the overall functional status of the cardiocirculatory system.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1615-2573
    Schlagwort(e): Negative feedback ; Transfer function ; Exercise
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary In exercise training, precise control of exercise intensity would maximize the training efficacy while minimizing risks. To adjust work rate, heart rate (HR) has been used as a measure of exercise intensity. Thus, we developed a servo-controller of HR using a cycle ergometer. After estimating the transfer function from work rate to HR, we optimized feedback parameters for achieving a quick and stable HR response by means of a computer simulation. We then examined the performance of the servo-controller of HR in 55 healthy volunteers. We set the target HR at 60% and 75% of the age-predicted maximum HR. Times required for HR to reach 90% of the target HR were 136 ± 33 and 137 ± 22s in the respective protocols. Standard deviations of the steady-state difference between the target and measured HRs were 2.5 ± 0.6 and 3.8 ± 1.1 beats/min. We conclude that the developed servo-controller makes it possible to precisely regulate HR and, thereby, exercise intensity.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...