GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Keywords: Forschungsbericht
    Type of Medium: Online Resource
    Pages: Online-Ressource (20 S., 369 KB) , Ill., graph. Darst.
    Language: German
    Note: Förderkennzeichen BMBF 01EZ0759. - Verbund-Nr. 01059497 , Systemvoraussetzungen: Acrobat reader.
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    European journal of neuroscience 12 (2000), S. 0 
    ISSN: 1460-9568
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Neurotrophins have traditionally been regarded as slow-acting signals essential for neuronal survival and differentiation. Recent studies with neuronal slices, cultures and nerve ending preparations have shown that neurotrophins generate acute changes in nerve activity. Among the secondary sensory cells are the inner hair cells (IHC) and taste buds, cells which express the neurotrophic factors necessary for the survival of their innervating neurons. If in these cells neurotrophins acutely affect the nerve activity of their afferent neurons, as in the central nervous system (CNS), this may have important functional implications for the corresponding sensory transduction processes. The neurotrophin NT-3 has been reported to be expressed in IHCs. We chose an in vivo application system for the microiontophoretic supply of NT-3 in the subsynaptic region of the IHC. The effect of NT-3 on spontaneous and evoked afferent cochlear nerve activities in adult guinea pig inner ear was studied. We observed that NT-3 rapidly increases the spontaneous and glutamate-evoked firing rate of IHC afferents. Moreover, firing induced by both N-methyl- d-aspartate (NMDA) and α-amino-3-hydroxy-5-methylisoxazole-4-propionic acid (AMPA) were specifically enhanced during the presence of NT-3, a process which was selectively blocked by the tyrosine kinase receptor inhibitor K252a. Because we localized NT-3 mRNA not only in IHCs but also in the spiral ganglion, we propose that similar to other sensory systems, afferent and autocrine neurotrophin activities may be responsible for survival of cochlear neurons. In addition, NT-3 in IHCs may operate as a signal-dependent, intrinsic neuromodulator and/or neuroprotector.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0014-5793
    Keywords: Clone ; Inward rectifier ; K^+ channel ; Site-directed mutagenesis ; Spermine
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 223 (1979), S. 405-405 
    ISSN: 1434-4726
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 72 (1985), S. 441-442 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1351
    Keywords: Cochlea ; Outer hair cells ; Echolocation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Isolated outer hair cells (OHCs) and explants ot the organ of Corti were obtained from the cochlea of the echolocating bat, Carollia perspicillata, whose hearing range extends up to about 100 kHz. The OHCs were about 10–30 μm long and produced resting potentials between-30 to -69 mV. During stimulation with a sinusoidal extracellular voltage field (voltage gradient of 2 mV/μm) cyclic length changes were observed in isolated OHCs. The displacements were most prominent at the level of the cell nucleus and the cuticular plate. In the organ of Corti explants, the extracellular electric field induced a radial movement of the cuticular plate which was observed using video subtraction and photodiode techniques. Maximum displacements of about 0.3–0.8 μm were elicited by stimulus frequencies below 100 Hz. The displacement amplitude decreased towards the noise level of about 10–30 nm for stimulus frequencies between 100–500 Hz, both in apical and basal explants. This compares well with data from the guinea pig, where OHC motility induced by extracellular electrical stimulation exhibits a low pass characteristic with a corner frequency below 1 kHz. The data indicate that fast OHC movements presumably are quite small at ultrasonic frequencies and it remains to be solved how they participate in amplifying and sharpening cochlear responses in vivo.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schwingungsmessungen ; Mechanik des Mittelohrs ; Verifikation von Computermodellen ; Bewegungsverhalten ; Key words Middle-ear mechanics ; Verification of computer models ; Dynamic behavior of ossicular motion ; Measurements of ossicular vibrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The dynamic behavior of the ossicular chain is very complex and is frequency-dependent. To date, this has still not been fully investigated or understood. There remains a lack of measurement procedures to pick up the motion of the ossicles and ear drum simultaneously with sufficient resolution. The presented paper reports simultanous measurements with laser-Doppler vibrometry at two points of the ossicular chain of cadaver specimens. Motions not observed were derived using mechanical simulation models on a computer and then evaluating appropriate mathematical equations. Using a sound stimulus, the displacement velocities of the umbo and stapes footplate were measured, and the corresponding transfer functions were derived by Fourier transform. Results were used for verification of the computer models. In the current investigations these models were refined and allow for the detailed investigation of the dynamic behavior of the ossicular chain, facilitating the optimal design of passive and active middle-ear implants.
    Notes: Zusammenfassung Das hochkomplexe, frequenzabhängige Bewegungsverhalten der Gehörknöchelchenkette beim Hörvorgang ist noch nicht zufriedenstellend geklärt. Eine wesentliche Ursache ist das Fehlen von Meß- und Untersuchungsverfahren, die jeden Punkt von Trommelfell und Ossikeln über den gesamten Frequenzbereich gleichzeitig mit hoher Empfindlichkeit erfassen können. Sie werden in absehbarer Zeit auch nicht zur Verfügung stehen. Hingegen stehen heute Meßtechniken zur Verfügung, die hochauflösende Bewegungsmessungen an einzelnen, wenigen Punkten entlang der Ossikelkette zulassen. In der vorliegenden Arbeit werden derartige Messungen vorgestellt und es wird gezeigt, wie das frequenzabhängige Bewegungsmuster der übrigen Ossikelkette mittels mechanischer Ersatzmodelle und deren mathematischer Gleichungen berechnet werden kann. Die hohe Präzision einer derartigen Vorgehensweise ist z.B. aus der Weltraumfahrt oder dem Fahrzeugbau bekannt. Ein leistungsfähiges Verfahren zur Untersuchung der Bewegungen kleinster Strukturen mit minimalen Schwingungsamplituden ist die Laserdopplervibrometrie (LDV), die hier zur Ermittlung des Übertragungsverhaltens der Gehörknöchelchenkette genutzt wird. Um das Transferverhalten zwischen unterschiedlichen Punkten zuverlässig bestimmen zu können, wurden Zweipunktmessungen durchgeführt, aus denen sich der Stimulus rechnerisch eliminieren läßt. Probleme bereiten hierbei u.a. der für Messungen schwierige Zugang zur Paukenhöhle. Mechanische Ersatzmodelle mit unterschiedlicher Komplexität wurden erstellt, die sich mit mathematischen Gleichungen beschreiben lassen. Anhand der Struktur, den Koeffizientenmatrizen und den Lösungen der Gleichungen läßt sich eine detaillierte Dynamikanalyse ausführen. Zur Verifikation der Simulationsmodelle wurden die LDV-Messungen an Felsenbeinpräparaten herangezogen. In der vorliegenden Arbeit werden die gemessenen Übertragungsfunktionen zwischen Umbo und Steigbügelfußplatte vorgestellt und mit den ermittelten Computermodellen verglichen. Man erkennt aus den Messungen Charakteristika des dynamischen Verhaltens, und es lassen sich Transferfunktionen ableiten, die ebenfalls mehrere Überhöhungen aufweisen. Ein Vergleich mit den Rechenergebnissen der mechanischen Simulationsmodelle zeigt die qualitative Übereinstimmung. Die bisher erstellten Ersatzmodelle sollen nach weiteren Verfeinerungen Aussagen zur gezielten Auslegung von Mittelohrprothesen ermöglichen.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schwerhörigkeit ; Implantierbare Hörgeräte ; Elektronisches Hörimplantat ; TICA ; Key words Sensorineural hearing loss ; Implantable hearing aid ; Electronic hearing implant ; TICA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Recently, Zenner et al. implanted the first totally implantable electronic hearing devices in patients with SNHL (HNO 46 [1998] 844–852). In the present report, technical and audiological features of the implant TICA are published. The development of the piezoelectric transducer and the microphone for implantation in the posterior wall of the auditory canal as components for the present fully implantable hearing system has already been described (HNO 45, 1997, 792–880). Here we report about our experience with the electronic main module that completes the TICA LZ 3001 system. This module is suited for implantation in the mastoid bone and contains the signal-processing electronics and an integrated battery that can be recharged transcutaneously with a portable charger. The recharging time is around 2 h for an implant operating time of 50h. The microphone and transducer connectors allow for easy replacement of the main module when the battery lifetime is reached. This lifetime is around 3–5 years. A small wireless remote control allows volume adjustment, contains an on/off switch, and permits selection of four different individual hearing programs. The basic audiological features are provided by a flexible, digitally programmable 3-channel-AGC-system with a peak clipping function. The total bandwidth is around 10 kHz. To our knowledge this is the first fully implantable hearing system that has been in implanted in humans.
    Notes: Zusammenfassung Kürzlich wurde über die Entwicklung eines elektromechanischen, piezoelektrischen Wandlers und eines Mikrofons zum subkutanen Einbau in die hintere Gehörgangswand als Komponenten eines zukünftigen vollständig implantierbaren Hörsystems für Innenohrschwerhörige berichtet (HNO 45, 1997, 792–880). Zwischenzeitlich konnte die Entwicklung eines elektronischen Hauptmoduls zur Implantation auf dem Planum mastoideum abgeschlossen werden, das diese Mikrofone und Wandler zu dem kompletten Hörimplantat TICA® LZ 3001 ergänzt. Dieses Hauptmodul enthält neben der signalverarbeitenden Elektronik eine spezielle Batterie, die transkutan mit einem portablen Ladegerät nachgeladen wird. Nach einer Volladung, die ca. 2 h benötigt, ist das Implantat für rund 50 h kontinuierlich betriebsbereit. Das Ladegerät wird ähnlich wie bei Mobiltelefonen in einer netzbetriebenen Station nachgeladen. Lösbare Steckverbindungen zu Mikrofon und Wandler ermöglichen den einfachen operativen Austausch des Hauptmoduls, wenn die Batterielebensdauer erreicht ist. Dies wird nach ca. 3–5 Jahren erwartet. Dem Patienten steht eine kleine, drahtlose Fernbedienung zur Verfügung, mit der Lautstärke, Ein/Aus sowie 4 Hörprogramme für unterschiedliche Hörsituationen eingestellt werden können. Die grundlegenden audiologischen Eigenschaften sind durch ein flexibel digital programmierbares 3-Kanal-AGC-System mit Peak-clipping-Funktion gegeben. Die gesamte Übertragungsbandbreite beträgt ca. 10 kHz. Das vollimplantierbare Hörsystem wurde im Rahmen der klinischen Erprobung Anfang Juni 1998 erstmals am Menschen angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schwerhörigkeit ; Cochlea-amplifier-Implantat ; Implantierbares Hörgerät ; TICA ; Key words Sensorineural hearing loss ; Cochlea amplifier implant ; Implantable hearing aid ; Electronic hearing implant ; TICA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary For the majority of patients with sensorineural hearing loss (SNHL) many available hearing aids often do not achieve satisfactory results. For these patients partially implantable hearing devices have been developed, allowing distortion-free hearing and speech intelligibility that may be superior to conventional hearing aids. The external parts of partial implants, however, may result in a patient’s stigmatization. Furthermore, they do not use the acoustic properties of the external auditory canal. Recently, we published the successful development of the first totally implantable hearing device for the treatment of SNHL (HNO 46 [1998] 853–863). Here we report the first implantations of this unique, totally implantable electronic hearing system in patients with SNHL: Implex TICA LZ 3001. The implant microphone is implanted subcutaneously in the outer ear canal near the ear drum. The signal is processed by a digitally programmable multichannel audioprocessor located subcutaneously on the bony skull behind the ear. A piezoelectric transducer is coupled to the body of the incus and drives the ossicular chain by vibratory actions. Energy is provided by an implantable battery. Implanted patients describe hearing as being distortion-free and transparent. Speech intelligibility and the hearing of music are improved. Patients may achieve better speech discrimination, especially in the presence of background noise. The aid can be used during sports, including swimming. To our knowledge, this is the first report of the implantation of a totally implantable electronic hearing system in patients. These results encourage further implantations of the totally implantable hearing system in the course of an ongoing clinical study.
    Notes: Zusammenfassung: Für die Mehrzahl der Innenohrschwerhörigen kann selbst mit modernster Hörgerätetechnik keine die Patienten zufriedenstellende Hörrehabilitation erzielt werden. Für diese große Zahl von Betroffenen ohne adäquate Versorgung sind teilimplantierbare Hörgeräte entwickelt worden, die konventionellen Hörgeräten besonders bei Klangtreue und Sprachverständlichkeit deutlich überlegen sein können. Allerdings können sie den Kranken durch außen an Kopf oder Körper zu tragende Teile stigmatisieren. Auch nutzen sie die Störschallunterdrückung als auch die auditorische Raumorientierung mittels des äußeren Gehörgangs noch nicht aus. Hier berichten wir über die ersten Implantationen eines neuartigen, vollständig implantierbaren Hörsystems (TICA® LZ 3001) bei Innenohrschwerhörigen. Es nimmt den Schall über ein trommelfellnahes Mikrophon durch die intakte Gehörgangshaut auf. Ein retroaurikulär subkutan implantierter, mehrkanaliger digital programmierbarer Audioprozessor verarbeitet das Signal und gibt es über einen piezoelektronischen Wandler im Mastoid an den Amboßkörper weiter. Energie wird durch eine implantierbare Batterie bereitgestellt. Implantierte Patienten empfinden das Gehörte als verzerrungsfrei und transparent. Sie verstehen Sprache und empfinden Musik besser als ohne Implantat. Insbesondere im Störlärm kann z.T. ein erheblich verbessertes Sprachverständnis erreicht werden. Die bisherigen Ergebnisse ermutigen, weitere Implantationserfahrungen mit dem vollständig implantierbaren Hörsystem zu sammeln.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Hereditäre Schwerhörigkeit ; Konsanguinität ; Key words Hereditary hearing loss ; Consanguinity ; Deafness in Turkey
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The authors describe a study in progress to identify Turkish families with hereditary hearing loss and isolate possible responsible disease genes. Due to extreme genetic heterogeneity and limited audiological differentiation of hereditary hearing loss, it is necessary to identify large or small families from genetic isolates to locate loci responsible for hearing loss on a chromosome. To accomplish this goal, the medical records of 3800 children were examined at the ENT Clinic of Ege University between 1975 and 1994. All were suspected of having various hearing impairments. Additionally, students from two schools for the hearing impaired in Izmir and Eskisehir, Turkey were examined. To date, 16 families with syndromal deafness and 55 families with non-syndromal hereditary hearing loss involving two or more affected individuals have been identified and categorized according to the mode of inheritance. The majority (66%) of the non-syndromal families showed an autosomal recessive pattern, 29% an autosomal dominant inheritance and 5% an X-linked mode of inheritance. In the study presented there has been a predominance of affected males versus females and the consanguinity rate was 22%.
    Notes: Zusammenfassung Die Häufigkeit von Taubheit im Kindesalter wird heute mit ca. 1/2000 angegeben und zu 60% auf genetische Ursachen zurückgeführt; 70% dieser tauben Kinder repräsentieren hierbei nicht-syndromale Hörstörungen. Die Lokalisierung und Identifizierung der zugrundeliegenden Gendefekte sind derzeit Gegenstand aktueller Forschungsprojekte. Entscheidend ist hierbei die klinische Dokumentation von Familien ausreichender Größe mit mehreren Betroffenen und die exakte audiometrische Evaluierung der Familien. Zu diesem Zweck wurden die Krankenakten von 3800 hörgeschädigten Kindern an der HNO-Klinik der Ege-Universität in Izmir analysiert und die Studenten zweier Schulen für Hörbehinderte im Raum Izmir untersucht. Ziel war hierbei die Identifikation von Familien mit hereditärer Schwerhörigkeit. Aufgrund dieser Untersuchungen konnten 55 Familien mit nicht-syndromaler und 16 Familien mit syndromaler Schwerhörigkeit identifiziert werden. Innerhalb der Familien mit nicht-syndromaler Schwerhörigkeit waren 12 mit einem autosomal-dominanten, 27 mit einem autosomal-rezessiven und 2 Familien mit einem x-gekoppelten Erbgang vereinbar. In 14 Familien war kein klarer Vererbungsmodus zu erkennen.