GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Publisher
Years
  • 1
    ISSN: 1432-0967
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Notes: Abstract The Elzevir Terrane of the Grenville Orogen in southern Ontario contains metapelites and abundant graphitic marbles that were regionally metamorphosed from the upper greenschist to upper amphibolite facies. Comparative thermometry was undertaken with widely used calibrations for the systems garnet-biotite, calcite-dolomite, and calcite-graphite. Temperatures that are obtained from matrix biotites paired with prograde garnet near-rim analyses are usually consistent with those determined using calcite-graphite thermometry. However, calcite-graphite thermometry occasionally yields low temperatures due to lack of equilibration of anomalously light graphite. Application of calcite-graphite and garnet-biotite systems may yield temperatures up to 70 °C higher than calcite-dolomite in amphibolite facies rocks. Calcite-dolomite temperatures most closely approach those from calcite-graphite and garnet-biotite when the samples contain a single generation of dolomite and calcite grains contain no visible dolomite exsolution lamellae. However, some of these samples yield temperatures considerably lower than temperatures calculated from calcite-graphite and garnet-biotite thermometry, indicating that the calcite-dolomite thermometer may have been partially reset during retrogression. Estimated peak metamorphic temperatures of regional metamorphism between Madoc (upper greenschist facies) and Bancroft (upper amphibolite facies) range from 500 to 650 °C. These results place the chlorite-staurolite isograd at 540 °C, the kyanite-sillimanite isograd at 590 °C, and the sillimanite-K-feldspar isograd at 650 °C. Although each thermometer may have an absolute uncertainty of as much as ±50 °C, the 50 to 60 °C temperature differences between the isograds are probably accurate to 10 to 20 °C. An incomplete picture of the thermal gradients can result from the application of only one thermometer in a given area. Simultaneous application of several systems allows one to recognize and overcome the inherent limitations of each thermometer.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...