GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2475-2481 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high-voltage pulse output modulator using a step-up transformer with two stages of magnetic pulse compression circuits has been developed as a spiker for the purpose of obtaining the breakdown of the gas mixture when using the spiker-sustainer excitation technique for pumping XeCl discharge lasers. When the transformer input is fed by a current pulse with a peak value and a full width of 1.16 kA and 1.6 μs, respectively, formed by a discharge of an initially charged 19-kV, 57-nF capacitance in series in the transformer primary loop, the 2.7-nF output capacitor bank (Cp) of the spiker can be charged up to 67 kV with a (10%–90%) rise time of 59 ns. The modulator has been tested at a repetition rate of up to 600 Hz in burst mode using a resistor in parallel with Cp as the load.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Liver, interventional procedures ; Lasers ; Liver, US studies ; Liver neoplasms, therapy ; Hyperthermia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The present report evaluates the efficacy and safety of percutaneous interstitial laser tissue ablation of the liver in nine New Zealand rabbits. A Nd: YAG laser was coupled to a quartz fibreoptic guide (600 μm) with a flat tip. The fibre and a thermocouple were placed in the lumen of two Chiba needles (18G) and these were inserted into the liver 10 mm apart under ultrasound guidance. The laser was fired for 5 min at 1, 3 and 5 W power, respectively, in three groups of rabbits. There were no acute complications and all the rabbits except one survived until the established time of sacrifice. The procedure induced a cavity surrounded by a zone (about 10 mm) of coagulative necrosis. After 2 weeks a strong peripheral inflammatory response was evident and after 4 weeks a capsule of connective tissue enclosed the lesions. Our study seems to offer a safe and rapid technique producing a “guaranteed kill radius” for the treatment of small hepatic neoplasms.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...