GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0047-2484
    Keywords: Baringo ; Kenya ; fossil vertebrates ; hominoids ; neogene ; palaeoflora ; palaeomagnetic calibration ; radiometric dating
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0047-2484
    Keywords: Baringo ; Kenya ; fossil vertebrates ; hominoids ; neogene ; palaeoflora ; palaeomagnetic calibration ; radiometric dating
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 93 (1987), S. 477-482 
    ISSN: 1432-2072
    Keywords: Cis-flupentixol ; Reinforced responding ; Motor effects ; Reinforcement efficacy ; Dopamine receptors (D1 and D2) ; Matching law equation ; Variable-interval schedule ; Water reinforcement ; Lever press ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We evaluated the effects of cis-flupentixol on reinforced responding. The experimental subjects were rats and the reinforced response was a lever press. The procedure was a five-component multiple schedule that provided five different reinforcement rates. Cis-flupentixol produced dose-dependent decreases in reinforced responding. An equation, the matching law, was fitted to the results. One parameter of this equation represents the estimated response rate asymptote. Cis-flupentixol produced dose-dependent decreases in the asymptotes. A second parameter of the equation represents the rate of reinforcement that maintains a one-half asymptotic response rate. Cis-flupentixol did not appear to affect this measure. There is evidence that the response rate asymptote measures motor components of response rate and that the reinforcement parameter measures the efficacy of the reinforcement maintaining the response. According to these results, cis-flupentixol systematically affected the motor-component of reinforced responding — it slowed down lever pressing — without affecting the subject's sensitivity to the reinforcer maintaining the response. In contrast, other neuroleptics have decreased the subjects' sensitivity to reinforcement, according to the matching law measures.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 343 (1990), S. 245-248 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Schwartz's contention is based partly on ice-core data from the Dye-3 site on the Greenland ice cap (2,490m; 65°12' N, 43°47' W) which indicate that the background concentration of excess sulphate in snow deposited there has tripled over the past 90 years6'8. (Background ...
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 193 (1962), S. 870-871 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] At this point it is necessary to digress in order to clarify a point on coal constitution, since we feel that Mr. Wyss's objections stem largely from the fact that his views on this matter differ materially from our own. It is generally agreed that coal consists either of a molecular aggregate ...
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 192 (1961), S. 128-129 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] IT is generally recognized that oxygen occupies a position in the structure of coal comparable with that of carbon. Consequently, much work has been carried out in order to determine the percentage of oxygen contained in the various functional groups in coals of a wide range of carbon content. A ...
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    The international journal of cardiovascular imaging 11 (1995), S. 71-80 
    ISSN: 1573-0743
    Keywords: automatic boundary detection ; quantitative echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Systolic and diastolic left ventricular function was assessed using an echocardiographic automatic boundary detection system (ABD) in 50 unselected patients undergoing left cardiac catheterisation. Automatic boundary detection system derived parameters (fractional area change [FAC], peak positive rate of area change [+dA/dt] and peak negative rate of area change [−dA/dt]) were compared with invasively (left ventricular angiography and pressures) and non invasively (Doppler mitral filling velocities and isovolumic relaxation time) acquired conventional indices of ventricular function. Adequate detection of endocardial boundaries and subsequent measurements using the ABD system were achieved in 40/50 (80%) patients in the short axis parasternal view, in 41/50 (82%) in the apical four chamber view and in 34/50 (68%) in both views. For the whole group of patients the FAC (maximal left ventricular diastolic area — minimal left ventricular systolic area/maximal left ventricular diastolic area) estimated in the short axis view correlated with the angiographic ejection fraction (EF) measured in the right oblique projection (r=0.51, p〈0.001). There was only a weak correlation of the FAC estimated in the apical four chamber view with the EF (r= 0.36, p〈0.01). The mean FAC (mean value of the FAC in the short axis and apical four chamber views) correlated reasonably with the EF (r=0.62, p〈0.0001). There was no correlation between ABD derived parameters and left ventricular end diastolic pressure (LVEDP) in these patients. In a subgroup of patients with normal coronary arteries and left ventricular function (n = 17), although there was no correlation between EF and FAC, there was a strong positive correlation between FAC (apical four chamber and mean) and LVEDP (r=0.77, p〈0.01 and r=0.87, p〈0.01 respectively). No correlation was found in these patients between EF and LVEDP. In a further subgroup of patients with angiographically abnormal left ventricular function (EF〈45%), there was a positive correlation between FAC (short axis, apical four chamber and mean) and EF (r=0.52, p〈0.05, r=0.83, p〈0.0001 and r=0.80, p〈0.001 respectively) and a negative correlation between FAC (short axis and mean) and LVEDP (r=−0.52, p〈0.05 and r=−0.60, p〈0.01 respectively). There was also a negative correlation between LVEDP and EF in the same subgroup of patients (r=−0.65, p〈0.01). None of the ABD derived parameters correlated with non invasively acquired indices of diastolic ventricular function (peak early left ventricular diastolic filling blood velocity [Emax], peak late diastolic velocity [Amax], E/A ratio and isovolumic relaxation time [IVRT], but there was a consistent positive correlation between −dP/dt and + dA/dt estimated in the four chamber view (r=0.5, p〈0.01, all patients). Therefore, although ABD derived parameters cannot be used in an interchangeable way with ejection fraction, they do provide a rapid, bedside method for the assessment of left ventricular function. FAC and dA/dt do appear to reflect left ventricular performance both in patients with normal ventricles and in patients with impaired left ventricular function.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2017-01-31
    Description: Recent experiments, mainly in terrestrial environments, have provided evidence of the functional importance of biodiversity to ecosystem processes and properties. Compared to terrestrial systems, aquatic ecosystems are characterised by greater propagule and material exchange, often steeper physical and chemical gradients, more rapid biological processes and, in marine systems, higher metazoan phylogenetic diversity. These characteristics limit the potential to transfer conclusions derived from terrestrial experiments to aquatic ecosystems whilst at the same time provide opportunities for testing the general validity of hypotheses about effects of biodiversity on ecosystem functioning. Here, we focus on a number of unique features of aquatic experimental systems, propose an expansion to the scope of diversity facets to be considered when assessing the functional consequences of changes in biodiversity and outline a hierarchical classification scheme of ecosystem functions and their corresponding response variables. We then briefly highlight some recent controversial and newly emerging issues relating to biodiversity-ecosystem functioning relationships. Based on lessons learnt from previous experimental and theoretical work, we finally present four novel experimental designs to address largely unresolved questions about biodiversity-ecosystem functioning relationships. These include (1) investigating the effects of non-random species loss through the manipulation of the order and magnitude of such loss using dilution experiments; (2) combining factorial manipulation of diversity in interconnected habitat patches to test the additivity of ecosystem functioning between habitats; (3) disentangling the impact of local processes from the effect of ecosystem openness via factorial manipulation of the rate of recruitment and biodiversity within patches and within an available propagule pool; and (4) addressing how non-random species extinction following sequential exposure to different stressors may affect ecosystem functioning. Implementing these kinds of experimental designs in a variety of systems will, we believe, shift the focus of investigations from a species richness-centred approach to a broader consideration of the multifarious aspects of biodiversity that may well be critical to understanding effects of biodiversity changes on overall ecosystem functioning and to identifying some of the potential underlying mechanisms involved.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2013-11-08
    Description: Aims Pocket-size imaging devices (PSID) are now available; their potential role in a hospital environment has been investigated but still remains undefined. Methods and results We evaluated the effectiveness of PSID in 92 patients referred for bedside transthoracic echocardiogram (TTE). Patients were included where there was a focused clinical question: quantification of left ventricular function (LVF); presence of regional wall motion abnormalities (RWMA); evidence of pericardial effusion, exclusion of significant valve pathology. Each patient underwent an echocardiography evaluation using PSID and TTE. In 83 patients [ k = 90%, 95% CI (82.2–95.4)], it was possible to answer the clinical question by PSID examination alone. There was agreement between the findings of PSID and TTE in 86 cases [79%; k = 47%, 95% CI (12.8–82.0)], in three cases, the clinical question was not answered by both modalities. When the clinical question was focused on LVF, the agreement was excellent [ k = 96%, 95% CI (95.3–97.9)], as was the agreement in the detection of RWMA [ k = 94.57%, 95% CI (82.4–95.1)]. There was also good concordance in the detection of valve pathology and pericardial effusion. Using PSID, the reduction in the scanning and reporting time was 66%. The cost-effectiveness analysis produced very favourable results: with PSE, we obtained an overall cost saving per scan of 76%, compared with TTE. Conclusion This study demonstrates that PSID can provide a valuable alternative to TTE in the presence of focused clinical questions and can provide an efficient way of delivering a ward-based transthoracic echo service.
    Print ISSN: 1525-2167
    Electronic ISSN: 1532-2114
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2016-07-22
    Description: Transcatheter therapies for the treatment of valve heart diseases have expanded dramatically over the last years. The new developments and improvements in devices and techniques, along with the increasing expertise of operators, have turned the catheter-based approaches for valvular disease into an established treatment option. Various imaging techniques are used during these procedures, but echocardiography plays an essential role during patient selection, intra-procedural monitoring, and post-procedure follow-up. The echocardiographic assessment of patients undergoing transcatheter interventions places demands on echocardiographers that differ from those of the routine evaluation of patients with valve disease, and there is a need for specific expertise for those working in the cath lab. In the context of the current rapid developments and growing use of transcatheter valve therapies, this document intends to update the previous recommendations and address new advancements in imaging, particularly for those involved in any stage of the treatment of patients with valvular heart diseases.
    Print ISSN: 1525-2167
    Electronic ISSN: 1532-2114
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...