    ISSN: 1619-7089
    Keywords: Coronary bypass surgery ; Thallium-201 reinjection ; Myocardial viability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Twenty-two patients with single-vessel left anterior descending coronary artery disease were investigated by means of dipyridamole stress thallium-201 myocardial perfusion scintigraphy, using single photon emission tomography (SPET), 1 week before and 2–5 weeks after coronary bypass surgery. The dose of dipyridamole was 0.56 mg/kg, and the injected activity of 201T1 was 74 MBq. Before surgery, and after completion of the redistribution study, a further 37 MBq of 201T1 was injected. Ten minutes and 1 h later, repeated SPET imaging were performed. SPET images were evaluated both subjectively and semiquantitatively, using a five-grade segmental defect score system, with higher scores for more severe perfusion defects. Before surgery, the 3-h redistribution images revealed complete or partial persistence of the perfusion defects in all patients. On the images taken 10 min after reinjection, these defects were completely filled in four cases, and partially filled in ten cases. Further positive changes were observed on the 1-h post-reinjection images in four cases. Three of the 1-h post-reinjection images exhibited a paradox redistribution. The stress images after surgery corresponded well to the 201T1 distribution on the preoperative 1-h post-reinjection images in 11 cases. The average of the segmental defect severity scores was 17.0 after stress, 10.1 at rest, 7.1 10 min after reinjection and 6.4 1 h after reinjection. After surgery, the average of both the post-stress and the 3-h redistribution scores was 3.1. The correlation coefficients between the segmental scores of the postoperative resting study and the preoperative 3-h resting and the 10-min and 1-h post-reinjection studies were 0.72, 0.69 and 0.78, respectively. It is concluded that post-reinjection 201T1 images before surgery are good predictors of myocardial perfusion after revascularization. The best results are obtained if imaging is performed 1 h after reinjection.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Myocardial imaging ; Upward creep ; Motion artefacts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The upward creep of the heart during myocardial single photon emission tomography (SPET) acquisition has been reported as a frequent source of false-positive results. The aim of this study was to simplify the detection and correction of this upward creep and to estimate its clinical relevance during routine patient care. To recognize the upward heart motion a straight line was fitted to the upper and lower border of consecutively displayed tomographic projection images. In this way, vertical translation of at least 1 pixel in size could be detected easily. On the assumption of a slow but continuous upward motion a fast interpolation correction method was developed. From 100 consecutive, supine, ergometric exercise studies, 1, 2 or 3 pixels of upward creep were found in 16, 4 or 3 patients, respectively. It was found that an upward creep of at least 2 pixels (7/100 cases) led to evident, mostly antero-septal defects on quantitative bull's-eyes, whereas only upward creeps of 3 pixels or more (3/100 cases) produced false-positive diagnostic results. The simple correction method offered a sufficient compensation of image and/or bull's-eye artefacts. These clinical findings could be reproduced in a computer model. Thus, it can be stated that clinically significant upward creep of the heart during stress SPET acquisition is relatively rare; it may have been overestimated in the past, and its artificial effects can be corrected by a quick and simple algorithm.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Key words: Positron emission tomography – Performance evaluation – Uniformity measurement – Geometric arc correction – Spline interpolation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to demonstrate the necessity of an off-centre uniformity measurement during performance evaluation and acceptance testing of a positron emission tomography (PET) system. To this end, the effect of different methods of geometric arc correction on image uniformity was considered. The arc correction routine of the system software of a particular PET scanner family was tested in computer simulations, phantom measurements and a patient study. Various methods of geometric arc correction – nearest neighbour interpolation, linear interpolation and cubic smoothing spline interpolation – were applied to the same data. Uniformity was evaluated both visually and quantitatively using intensity profiles and regions of interest. The arc correction routine of the PET scanner family produced significant ring artefacts and led to overestimation of tracer uptake by up to 15%. Since uniformity measurements are usually performed using a cylindrical phantom at the centre of the transverse field of view, these artefacts are not detected. In conclusion, the standards for performance evaluation of a PET scanner should be extended by inclusion of an off-centre uniformity measurement at the edge of the transverse field of view. On the basis of our comparison of different methods for geometric arc correction, we suppose that cubic smoothingspline interpolationmight improve the relation between statistical noise reduction and spatial resolution as compared with conventional linear interpolation.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...