GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-0743
    Keywords: ejection fraction ; fully automated data processing ; phase analysis ; sectorial analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We describe a fully automated method for quantification of left ventricular performance by equilibrium radionuclide ventriculographic studies, based on subdivision of the left ventricular region into 9 equiangular sectors. The precise identification of the left ventricular contours is achieved by the use of morphological and functional criteria in a sequential edge detection algorithm with a success rate of 96%. In addition to left ventricular global and sectorial ejection fraction the first harmonic of the corresponding Fourier spectrum is approximated to each sectorial time-activity curve and to the global one. Sectorial phase is calculated as the difference between the phase of the sectorial and global first Fourier component. Computerized comparison between the sectorial parameters at rest and during peak exercise localizes and classifies the degree of global and regional impairment in response to exercise. The processing time of 60 sec makes this method suitable for routine use. The validity of our procedure has been tested in 34 patients before and after successful transluminal coronary angioplasty. In these patients, 73% of the stenosed vessels before dilatation were localized by sectorial ejection fraction, 77% by sectorial phases, and 88% by the combination of both.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Cardiac transplantation ; Sympathetic re-innervation ; Iodine-123 metaiodobenzylguanidine ; Thallium-201 ; Dual-isotope technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cardiac transplantation entails surgical disruption of the sympathetic nerve fibres from their somata, resulting in sympathetic denervation. In order to investigate the occurrence of sympathetic re-dnnervation, neurotransmitter scintigraphy using the norepinephrine analogue iodine-123 metaiodobenzylguanidine (MIBG) was performed in 15 patients 2–69 months after transplantation. In addition, norepinephrine content and immunohistochemical reactions of antibodies to Schwarm cell-associated S100 protein, to neuron-specific enolase (NSE) and to norepinephrine were examined in 34 endomyocardial biopsies of 29 patients 1–88 months after transplantation. Anterobasal123I-MIBG uptake indicating partial sympathetic re-dnnervation could be shown in 40% of the scintigraphically investigated patients 37–69 months after transplantation. In immunohistochemical studies 83% of the patients investigated 1–72 months after transplantation showed nerve fibres in their biopsies but not positive reaction to norepinephrine. Significant norepinephrine content indicating re-dnnervation could not be detected in any biopsy. It was concluded that in spite of the lack of norepinephrine content there seemed to be immunohistological and scintigraphic evidence of sympathetic re-dnnervation. An explanation for this contradictory finding may be the reduced or missing norepinephrine storage ability compared to the restored uptake ability of regenerated sympathetic nerve fibres.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Cardiac transplantation ; Radionuclide ventriculography ; Left ventricular function ; Cardiac allograft rejection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Discrepant results have previously been reported concerning long-term left ventricular function in the human transplanted heart as assessed by radionuclide ventriculography. In this study, radionuclide ventriculograms were obtained at rest and during exercise in 19 patients 〈6 months, 7–12 months, 13–24 months and 〉24 months after transplantation. Ejection fraction decreased significantly from 〈6 months to 13–24 months after transplantation (rest: 69.1%±9.7% to 56.7%±8.3%, P〈0.05; exercise: 70.4%±11.3% to 59%±8%, P〈0.05). Heart rate increased significantly during exercise after 〉2 years (90.2±10.5 beats/min to 103.5±15 beats/min, P〈0.05) but not within 6 months after transplantation (98.5±12.8 beats/min to 99.07±15.8 beats/min). Left ventricular end-diastolic volume remained unchanged. Peak filling rate at rest decreased significantly from 4.2±0.96 edv/s 〈6 months after transplantation to 3.3±0.66 edv/s (P〈0.05) 13–24 months and 3.3±0.64 edv/s (P〈0.05)〉24 months after cardiac transplantation. Exercise peak filing rate did not change significantly. It is concluded that radionuclide ventriculography demonstrates a decrease in systolic left ventricular function in the long-term course after cardiac transplantation. A significant increase in exercise peak heart rate may be due to autonomic reinnervation. Differences in the literature concerning left ventricular function may be due to different observation intervals following cardiac transplantation.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 8 (1983), S. 77-83 
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A fully automated computer program is described for processing equilibrium radionuclide ventriculography data with regard to global and sectorial left ventricular ejection fraction. The precise identification of the left ventricular outline, a prerequisite for reproducible determination of sectorial ejection fraction, was achieved by using morphological and functional criteria in a sequential edge detection technique. The high reproducibility of this method (correlation coefficient r: global ejection fraction r=0.96, sectorial ejection fraction r=0.82–0.97) allows the evaluation of a mean normal sectorial ejection fraction profile and its adaptation to the individual left ventricle. Computerized comparison between individual and adjusted normal sectorial ejection fraction permits quantitation of the degree and localization of functional impairment at rest, sectorial comparison between ejection fraction at rest and during peak exercise is used for the detection of ischemic functional impairment. The success rate of end diastolic left ventricular edge detection of 96% and the processing time of 150 s makes this method suitable for routine use.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...