GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Years
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: At present, patients with documented sustained VT or resuscitated cardiac arrest (CA) are treated with ICDs. The aim of this study was to retrospectively evaluate if a routine electrophysiological study should be recommended prior to ICD implantation. In 462 patients referred for ICD implantation because of supposedly documented VT (n = 223) or CA (n = 239) , electrophysiological study was routinely performed. In 48% of the patients with CA, sustained VT or VF was inducible. Electrophysiological study suggested conduction abnormalities (n = 11) or supraventricular tachyarrhythmias (n = 3) in conjunction with severely impaired left ventricular function to have been the most likely cause of CA in 14 (5.9%) of 239 patients. Likewise, sustained VT was only inducible in 48% of patients with supposedly documented VT. Of these inducible VTs, nine were diagnosed as right ventricular outflow tract tachycardia or as bundle branch reentry tachycardia. Supraventricular tachyarrhythmias judged to represent the clinical event were the only inducible arrhythmia in 35 (16%) patients (AV nodal reentrant tachycardia [n = 7] , AV reentry tachycardia [n = 4] , atrial flutter [n = 19] , and atrial tachycardia [n = 5] ). Based on findings from the electrophysiological study, ICD implantation was withheld in 14 (5.9%) of 239 patients with CA and in 44 (19.7%) of 223 patients with supposedly documented VT. During electrophysiological study, VT or VF was only reproducible in about 50% of patients with supposedly documented VT or CA. Electrophysiological study revealed other, potentially curable causes for CA or supposedly documented VT in 12.6% (58/462) of all patients, indicating that ICD implantation can potentially be avoided or at least postponed in some of these patients. Based on these retrospective data, routine electrophysiological study prior to ICD implantation seems to be advisable. (PACE 2003; 26:1715–1721)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , U.S.A . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: WERETKA, S., et al. : Ventricular Oversensing: A Study of 101 Patients Implanted with Dual Chamber Defibrillators and Two Different Lead Systems. Modern dual chamber ICD systems are able to overcome various sensing problems. However, improvement of their performance is still required. The aim of this study was to assess the sensing function in 101 consecutive patients (84 men, 17 women; mean age 63 ± 12 years; mean follow-up 24 ± 4 months) implanted with dual chamber defibrillators and integrated (IB) or dedicated bipolar (DB) lead systems. Follow-up data were analyzed for the presence of ventricular oversensing. Oversensing occurred in 25 (25%) patients, significantly more frequent in patients implanted with IB compared to DB lead systems (21/52 vs 4/49, P = 0.0002). Patients with cardiomyopathies (CMs) were more prone to sensing malfunctions than patients with no CM (12/30 vs 13/71, P = 0.04). T wave oversensing (n = 14), respirophasic ventricular oversensing (n = 4), and P wave oversensing (n = 6) were the most common pitfalls of ventricular sensing. P wave oversensing was unique to the IB lead system. CT scans performed in these patients disclosed the position of the RV coil to be proximal to the tricuspid area. Four patients received inappropriate ICD shocks due to oversensing. In all but two patients who received lead revision, oversensing was resolved by noninvasive means. In conclusion: (1) ventricular oversensing is a common problem occurring in up to 25% of patients with dual chamber ICDs; (2) P wave oversensing is a ventricular sensing problem affecting function of 11% of dual chamber devices with IB lead systems; (3) IB leads are significantly more susceptible to T wave and P wave oversensing than DB leads; and (4) patients with cardiomyopathies are more prone to oversensing than patients with other heart diseases. (PACE 2003; 26[Pt. I]:65–70)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...